8 research outputs found

    Impact of lockdown during Covid‐19 pandemic on physical activity and arrhythmia burden in heart failure patients

    Get PDF
    Background Restricted outdoor activity during COVID-19 related lockdown may accelerate heart failure (HF) progression and thereby increase cardiac arrhythmias. We analyzed the impact of March/April 2020 lockdown on physical activity and arrhythmia burden in HF patients treated with cardiac resynchronization therapy (CRT) devices with daily, automatic remote monitoring (RM) function. Methods The study cohort included 405 HF patients enrolled in Observation of Clinical Routine Care for Heart Failure Patients Implanted with BIOTRONIK CRT Devices (BIO|STREAM.HF) registry in 16 countries, who had left ventricular ejection fraction (LVEF) = 8 min/day in 46.5% of patients; predictors were higher LVEF, lower NYHA class, no defibrillator indication, and more activity before lockdown. AHRE burden increased by >= 17 min/day in 4.7% of patients; predictors were history of atrial fibrillation, higher LVEF, higher body mass index, and activity decrease during lockdown. Conclusion Unfavorable changes in physical activity, AHRE burden, and follow-up rate were observed during lockdown, but not in ventricular arrhythmia

    Admission blood glucose and 10-year mortality among patients with or without pre-existing diabetes mellitus hospitalized with heart failure

    No full text
    Abstract Background High admission blood glucose (ABG) level has been associated with a poor short-term outcome among non-diabetic patients with heart failure (HF). We aimed to investigate the association between ABG levels and long-term (10 years) mortality in patients with or without pre-existing diabetes mellitus (DM) admitted with HF. Methods We analyzed data on 1811 patients with DM and 2182 patients without pre-existing DM who were hospitalized with HF during a prospective national survey. The relationship between ABG and 10-year mortality was assessed using the Cox proportional hazard model adjusting for multiple variables. ABG was analyzed both as a categorical (200 mg/dL) and as a continuous variable. Results At 10 years of follow-up the cumulative probability of mortality was 85 and 78% among patients with DM and patients with no pre-existing DM (p 200 mg/dL had an increased mortality risk (>200 mg/dL versus 200 mg/dL is associated with increased mortality risk

    Albumin as a Prognostic Marker for Atrial Fibrillation Recurrence following Cryoballoon Ablation of Pulmonary Venous

    No full text
    Introduction: Atrial fibrillation (AF) recurrence following pulmonary vein isolation (PVI) ablation has clinical significance. Identifying risk factors for AF recurrence is important. We investigated serum albumin (SA) levels (g/dL) as a prognostic factor for the recurrence of AF following cryoballoon PVI ablation. Methods: We included patients who underwent cryoballoon PVI ablation at our institution between the years 2013 and 2018. The primary outcome was recurrence of AF during follow up. Results: Our cohort consisted of 126 patients (67% males, mean age 61.8 ± 10.0 years). The pattern of AF amongst the cohort was paroxysmal in 62.5%, persistent in 25.4%, and longstanding persistent in 6.3%. Those with lower SA levels had a mean AF duration significantly less than those with higher SA levels (2.81 years, 7.34 years, and 6.37 years for SA levels of p = 0.003). Patients with lower SA levels were significantly more likely to have had more previous cardioversions and a larger left atrial area and volume. The mean follow-up was 380 days, in which the AF recurrence rate was 20.6%. Patients with lower SA level had significantly more AF recurrences (47.4%, 16.7%, and 2.2% for SA levels of p p < 0.001). Conclusion: SA levels were found to be a strong independent marker for AF recurrence following PVI ablation

    Consumer-Led Screening for Atrial Fibrillation: Frontier Review of the AF-SCREEN International Collaboration.

    No full text
    The technological evolution and widespread availability of wearables and handheld ECG devices capable of screening for atrial fibrillation (AF), and their promotion directly to consumers, has focused attention of health care professionals and patient organizations on consumer-led AF screening. In this Frontiers review, members of the AF-SCREEN International Collaboration provide a critical appraisal of this rapidly evolving field to increase awareness of the complexities and uncertainties surrounding consumer-led AF screening. Although there are numerous commercially available devices directly marketed to consumers for AF monitoring and identification of unrecognized AF, health care professional-led randomized controlled studies using multiple ECG recordings or continuous ECG monitoring to detect AF have failed to demonstrate a significant reduction in stroke. Although it remains uncertain if consumer-led AF screening reduces stroke, it could increase early diagnosis of AF and facilitate an integrated approach, including appropriate anticoagulation, rate or rhythm management, and risk factor modification to reduce complications. Companies marketing AF screening devices should report the accuracy and performance of their products in high- and low-risk populations and avoid claims about clinical outcomes unless improvement is demonstrated in randomized clinical trials. Generally, the diagnostic yield of AF screening increases with the number, duration, and temporal dispersion of screening sessions, but the prognostic importance may be less than for AF detected by single-time point screening, which is largely permanent, persistent, or high-burden paroxysmal AF. Consumer-initiated ECG recordings suggesting possible AF always require confirmation by a health care professional experienced in ECG reading, whereas suspicion of AF on the basis of photoplethysmography must be confirmed with an ECG. Consumer-led AF screening is unlikely to be cost-effective for stroke prevention in the predominantly young, early adopters of this technology. Studies in older people at higher stroke risk are required to demonstrate both effectiveness and cost-effectiveness. The direct interaction between companies and consumers creates new regulatory gaps in relation to data privacy and the registration of consumer apps and devices. Although several barriers for optimal use of consumer-led screening exist, results of large, ongoing trials, powered to detect clinical outcomes, are required before health care professionals should support widespread adoption of consumer-led AF screening

    Antibacterial Envelope to Prevent Cardiac Implantable Device Infection

    No full text
    Background Infections after placement of cardiac implantable electronic devices (CIEDs) are associated with substantial morbidity and mortality. There is limited evidence on prophylactic strategies, other than the use of preoperative antibiotics, to prevent such infections. Methods We conducted a randomized, controlled clinical trial to assess the safety and efficacy of an absorbable, antibiotic-eluting envelope in reducing the incidence of infection associated with CIED implantations. Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. The primary end point was infection resulting in system extraction or revision, long-term antibiotic therapy with infection recurrence, or death, within 12 months after the CIED implantation procedure. The secondary end point for safety was procedure-related or system-related complications within 12 months. Results A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary end point occurred in 25 patients in the envelope group and 42 patients in the control group (12-month Kaplan-Meier estimated event rate, 0.7% and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval [CI], 0.36 to 0.98; P=0.04). The safety end point occurred in 201 patients in the envelope group and 236 patients in the control group (12-month Kaplan-Meier estimated event rate, 6.0% and 6.9%, respectively; hazard ratio, 0.87; 95% CI, 0.72 to 1.06; P&lt;0.001 for noninferiority). The mean (+/- SD) duration of follow-up was 20.7 +/- 8.5 months. Major CIED-related infections through the entire follow-up period occurred in 32 patients in the envelope group and 51 patients in the control group (hazard ratio, 0.63; 95% CI, 0.40 to 0.98). Conclusions Adjunctive use of an antibacterial envelope resulted in a significantly lower incidence of major CIED infections than standard-of-care infection-prevention strategies alone, without a higher incidence of complications
    corecore