304 research outputs found

    Impact of imaging protocol on left ventricular ejection fraction using gated-SPECT myocardial perfusion imaging

    Get PDF
    10noopenopenMarcassa, C; Giubbini, R.; Acampa, W.; Cittanti, C.; Djepaxhija, O.; Gimelli, A.; Kokomani, A.; Medolago, G.; Milan, E.; Sciagrà, R.Marcassa, C; Giubbini, Raffaele; Acampa, W.; Cittanti, C.; Djepaxhija, O.; Gimelli, A.; Kokomani, A.; Medolago, Giuseppe; Milan, E.; Sciagrà, R

    Possible additional value of 18FDG-PET in managing pancreas intraductal papillary mucinous neoplasms: Preliminary results

    Get PDF
    Although some clinical and radiological features may predict malignancy presence in intraductal papillary mucinous pancreas neoplasms, preoperative diagnosis remains difficult. In this study we present 7 patients with Intraductal Papillary Mucinous Neoplasm (IPMN) studied both with 18FDG-PET and magnetic resonance cholangiopancreatography (MRCP). A focal hypermetabolism was documented in 2 patients (the standardized uptake value in the neoplastic foci was 6.7 and 9), while absence of FDG uptake in the neoplasm area was recorded in the remaining 5 cases. Mean follow-up was 27 months (range 21–34). The final judgement was benign IPMN in 5 cases and malignant IPMN in 2. PET scan always correctly predicted the presence or absence of malignancy, while MRCP failed to detect malignancy in 3/7 cases. In conclusion, this preliminary experience suggests that 18FDG-PET may prove useful for malignancy detection in IPMN, improving differential diagnosis with benign intraductal papillary growth by functional data

    Minimal Extrathyroidal Extension in Predicting 1-Year Outcomes: A Longitudinal Multicenter Study of Low-to-Intermediate-Risk Papillary Thyroid Carcinoma (ITCO#4)

    Get PDF
    Background: The role of minimal extrathyroidal extension (mETE) as a risk factor for persistent papillary thyroid carcinoma (PTC) is still debated. The aims of this study were to assess the clinical impact of mETE as a predictor of worse initial treatment response in PTC patients and to verify the impact of radioiodine therapy after surgery in patients with mETE. Methods: We reviewed all records in the Italian Thyroid Cancer Observatory database and selected 2237 consecutive patients with PTC who satisfied the inclusion criteria (PTC with no lymph node metastases and at least 1 year of follow-up). For each case, we considered initial surgery, histological variant of PTC, tumor diameter, recurrence risk class according to the American Thyroid Association (ATA) risk stratification system, use of radioiodine therapy, and initial therapy response, as suggested by ATA guidelines. Results: At 1-year follow-up, 1831 patients (81.8%) had an excellent response, 296 (13.2%) had an indeterminate response, 55 (2.5%) had a biochemical incomplete response, and 55 (2.5%) had a structural incomplete response. Statistical analysis suggested that mETE (odds ratio [OR] 1.16, p = 0.65), tumor size >2 cm (OR 1.45, p = 0.34), aggressive PTC histology (OR 0.55, p = 0.15), and age at diagnosis (OR 0.90, p = 0.32) were not significant risk factors for a worse initial therapy response. When evaluating the combination of mETE, tumor size, and aggressive PTC histology, the presence of mETE with a >2 cm tumor was significantly associated with a worse outcome (OR 5.27 [95% confidence interval], p = 0.014). The role of radioiodine ablation in patients with mETE was also evaluated. When considering radioiodine treatment, propensity score-based matching was performed, and no significant differences were found between treated and nontreated patients (p = 0.24). Conclusions: This study failed to show the prognostic value of mETE in predicting initial therapy response in a large cohort of PTC patients without lymph node metastases. The study suggests that the combination of tumor diameter and mETE can be used as a reliable prognostic factor for persistence and could be easily applied in clinical practice to manage PTC patients with low-to-intermediate risk of recurrent/persistent disease

    Prevalence of interstitial pneumonia suggestive of COVID-19 at 18F-FDG PET/CT in oncological asymptomatic patients in a high prevalence country during pandemic period: a national multi-centric retrospective study

    Get PDF
    Purpose: To assess the presence and pattern of incidental interstitial lung alterations suspicious of COVID-19 on fluorine-18-fluorodeoxyglucose positron emission tomography (PET)/computed tomography (CT) ([18F]FDG PET/CT) in asymptomatic oncological patients during the period of active COVID-19 in a country with high prevalence of the virus. Methods: This is a multi-center retrospective observational study involving 59 Italian centers. We retrospectively reviewed the prevalence of interstitial pneumonia detected during the COVID period (between March 16 and 27, 2020) and compared to a pre-COVID period (January\u2013February 2020) and a control time (in 2019). The diagnosis of interstitial pneumonia was done considering lung alterations of CT of PET. Results: Overall, [18F]FDG PET/CT was performed on 4008 patients in the COVID period, 19,267 in the pre-COVID period, and 5513 in the control period. The rate of interstitial pneumonia suspicious for COVID-19 was significantly higher during the COVID period (7.1%) compared with that found in the pre-COVID (5.35%) and control periods (5.15%) (p < 0.001). Instead, no significant difference among pre-COVID and control periods was present. The prevalence of interstitial pneumonia detected at PET/CT was directly associated with geographic virus diffusion, with the higher rate in Northern Italy. Among 284 interstitial pneumonia detected during COVID period, 169 (59%) were FDG-avid (average SUVmax of 4.1). Conclusions: A significant increase of interstitial pneumonia incidentally detected with [18F]FDG PET/CT has been demonstrated during the COVID-19 pandemic. A majority of interstitial pneumonia were FDG-avid. Our results underlined the importance of paying attention to incidental CT findings of pneumonia detected at PET/CT, and these reports might help to recognize early COVID-19 cases guiding the subsequent management

    Normal values for nuclear cardiology: Japanese databases for myocardial perfusion, fatty acid and sympathetic imaging and left ventricular function

    Get PDF
    Myocardial normal databases for stress myocardial perfusion study have been created by the Japanese Society of Nuclear Medicine Working Group. The databases comprised gender-, camera rotation range- and radiopharmaceutical-specific data-sets from multiple institutions, and normal database files were created for installation in common nuclear cardiology software. Based on the electrocardiography-gated single-photon emission computed tomography (SPECT), left ventricular function, including ventricular volumes, systolic and diastolic functions and systolic wall thickening were also analyzed. Normal databases for fatty acid imaging using 123I-beta-methyl-iodophenyl-pentadecanoic acid and sympathetic imaging using 123I-meta-iodobenzylguanidine were also examined. This review provides lists and overviews of normal values for myocardial SPECT and ventricular function in a Japanese population. The population-specific approach is a key factor for proper diagnostic and prognostic evaluation

    Poster display II clinical general

    Get PDF

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection

    perchè la PET

    No full text
    corecore