268 research outputs found
The choice of statistical methods for comparisons of dosimetric data in radiotherapy
Purpose: Novel irradiation techniques are continuously introduced in radiotherapy to optimize the accuracy, the security and the clinical outcome of treatments. These changes could raise the question of discontinuity in dosimetric presentation and the subsequent need for practice adjustments in case of significant modifications. This study proposes a comprehensive approach to compare different techniques and tests whether their respective dose calculation algorithms give rise to statistically significant differences in the treatment doses for the patient. Methods: Statistical investigation principles are presented in the framework of a clinical example based on 62 fields of radiotherapy for lung cancer. The delivered doses in monitor units were calculated using three different dose calculation methods: the reference method accounts the dose without tissues density corrections using Pencil Beam Convolution (PBC) algorithm, whereas new methods calculate the dose with tissues density correction for 1D and 3D using Modified Batho (MB) method and Equivalent Tissue air ratio (ETAR) method, respectively. The normality of the data and the homogeneity of variance between groups were tested using Shapiro-Wilks and Levene test, respectively, then non-parametric statistical tests were performed. Specifically, the dose means estimated by the different calculation methods were compared using Friedmanâs test and Wilcoxon signed-rank test. In addition, the correlation between the doses calculated by the three methods was assessed using Spearmanâs rank and Kendallâs rank tests Results: The Friedmanâs test showed a significant effect on the calculation method for the delivered dose of lung cancer patients (p 0.001). The density correction methods yielded to lower doses as compared to PBC by on average (â5â±â4.4 SD) for MB and (â4.7â±â5 SD) for ETAR. Post-hoc Wilcoxon signed-rank test of paired comparisons indicated that the delivered dose was significantly reduced using density-corrected methods as compared to the reference method. Spearmanâs and Kendallâs rank tests indicated a positive correlation between the doses calculated with the different methods. Conclusion: This paper illustrates and justifies the use of statistical tests and graphical representations for dosimetric comparisons in radiotherapy. The statistical analysis shows the significance of dose differences resulting from two or more techniques in radiotherapy
Prosper: image and robot-guided prostate brachytherapy
Brachytherapy for localized prostate cancer consists in destroying cancer by
introducing iodine radioactive seeds into the gland through hollow needles. The
planning of the position of the seeds and their introduction into the prostate
is based on intra-operative ultrasound (US) imaging. We propose to optimize the
global quality of the procedure by: i) using 3D US; ii) enhancing US data with
MRI registration; iii) using a specially designed needle-insertion robot,
connected to the imaging data. The imaging methods have been successfully
tested on patient data while the robot accuracy has been evaluated on a
realistic deformable phantom
Automatic 3D seed location and orientation in CT images for prostate brachytherapy
International audienceIn prostate brachytherapy, the analysis of the 3D pose information of each individual implanted seed is one of the critical issues for dose calculation and procedure quality assessment. This paper addresses the development of an automatic image processing solution for the separation, localization and 3D orientation estimation of prostate seeds. This solution combines an initial detection of a set of seed candidates in CT images (using a thresholding and connected component method) with an orientation estimation using principal components analysis (PCA). The main originality of the work is the ability to classify the detected objects based on a priori intensity and volume information and to separate groups of seeds using a modified k-means method. Experiments were carried out on CT images of a phantom and a patient aiming to compare the proposed solution with manual segmentation or other previous work in terms of detection performance and calculation time
A 3D quantitative evaluation for assessing the changes of treatment planning system and irradiation techniques in radiotherapy
Purpose: This work proposes and compares two 3D global evaluation methods for assessing the alteration of calculated dose distributions when treatment planning system algorithms or irradiation techniques is modified in radiation therapy. Methods: The global analysis is based on gamma index (Îł) proposed by Low et al.1 and Chi (Ï) index proposed by Bakai et al.2. The Îł and Ï values are signed in order to identify the over and under estimating dosage. The 3D maps, the cumulative Gamma Voxels Histograms (GVHs) and Chi Voxels Histograms (CVHs) were generated using two software. The Îł and Ï criteria were set to 3 mm for the distance to agreement and 3% for dose. Pearson's Chi-squared test was applied to assess the statistically significance between GVHs and CVHs. We illustrated this method for the change of dose calculation algorithms for lung cancer, and the change of irradiation techniques for breast cancer. For each patient, 2 treatment plans were generated. For the example of change of dose calculation algorithms, a plan 1 was calculated using Pencil Beam Convolution (PBC) algorithm and a plan 2 was calculated using Modified Batho method (PBC-MB). For the example of change of irradiation technique, a plan 1 was calculated using Source Skin Distance SSD technique and a plan 2 was calculated using a single isocenter technique. Results: The 3D analysis based on Îł and Ï indexes showed a significant effect on the dosimetric representation in the lung cancer when we change the PBC algorithm to PBC-MB method. The comparison between the two irradiation techniques showed that the single isocenter technique produces a better dose distribution for the treatment of breast cancer. Pearson's Chi-squared test showed that there was no statistically significance between GVHs and CVHs generated by Îł and Ï indexes, (p > 0.05). The global analysis using 3D for Îł and Ï indexes confirmed the results obtained from dosimetric analysis. Conclusion: The methods proposed in this study provide useful tools for radiotherapy to compare two dose distributions obtained using different algorithms or different irradiation techniques. The Ï-index was (~190) times faster than Îł-index. The Ï-index is thus a valuable and more convenient method for 3D global analysis compared with Îł-index.------------------------Cite this article as: Chaikh A, Giraud JY, Balosso J. A 3D quantitative evaluation for assessing the changes of treatment planning system and irradiation techniques in radiotherapy. Int J Cancer Ther Oncol 2014; 2(3):02033. DOI: 10.14319/ijcto.0203.
A method to quantify and assess the dosimetric and clinical impact resulting from the heterogeneity correction in radiotherapy for lung cancer
Purpose: The aim of this study was to propose a method to quantify and assess the differences in dose computations using heterogeneity correction algorithms for the planning target volumes and organs at risk.Methods: Six patients with lung cancer treated with 3-dimensional conformal radiation therapy were included and analysed. Dose calculations were performed using the pencil beam convolution (PBC) algorithm without heterogeneity correction and the Modified Batho method (PBC-MB) with heterogeneity correction. For each patient, 3 treatment plans were generated using exactly the same beam configuration. In plan 1, the dose was calculated using the PBC algorithm. In plan 2, the dose was calculated using the PBC-MB. In plan 3, the dose was calculated using the PBC-MB method but with the same number of monitor units obtained from plan 1. To evaluate the treatment plans computed by the PBC and PBC-MB, the monitor units, dose at the isocenter, spatial isodose distribution, dose volume histograms, conformity index, homogeneity index, planning target volumes conformity index, and geometrical index were compared. A statistical analysis was carried out using Wilcoxon signed rank test. Results: The PBC-MB method in plan 2 produced a lower number of monitor units than in plan 1 using PBC algorithm (p < 0.001). Dosimetric parameters derived from the dose volume histograms were higher for the planning target volumes and organs at risks using PBC-MB method for plans 2 and 3 when compared to plan 1. There was no significant difference for all the quality indices between plan 1 and plan 2, (p > 0.05), but a significant difference for the geometric index between plans 2 and 3 (p = 0.002) was observed.Conclusion: The risks related to the modification from the homogeneity plan to the heterogeneity plan were the reduction of delivered dose in monitor units for the planning target volumes and the increment of the dose to the organs at risk. We suggest the adaption in the dose prescriptions when switching the dose calculation algorithm from the PBC to PBC-MB.------------------------------------------------------Cite this article as: Chaikh A, Giraud J, Balosso J. A method to quantify and assess the dosimetric and clinical impact resulting from the heterogeneity correction in radiotherapy for lung cancer. Int J Cancer Ther Oncol 2014; 2(1):020110.DOI: http://dx.doi.org/10.14319/ijcto.0201.1
Medical image computing and computer-aided medical interventions applied to soft tissues. Work in progress in urology
Until recently, Computer-Aided Medical Interventions (CAMI) and Medical
Robotics have focused on rigid and non deformable anatomical structures.
Nowadays, special attention is paid to soft tissues, raising complex issues due
to their mobility and deformation. Mini-invasive digestive surgery was probably
one of the first fields where soft tissues were handled through the development
of simulators, tracking of anatomical structures and specific assistance
robots. However, other clinical domains, for instance urology, are concerned.
Indeed, laparoscopic surgery, new tumour destruction techniques (e.g. HIFU,
radiofrequency, or cryoablation), increasingly early detection of cancer, and
use of interventional and diagnostic imaging modalities, recently opened new
challenges to the urologist and scientists involved in CAMI. This resulted in
the last five years in a very significant increase of research and developments
of computer-aided urology systems. In this paper, we propose a description of
the main problems related to computer-aided diagnostic and therapy of soft
tissues and give a survey of the different types of assistance offered to the
urologist: robotization, image fusion, surgical navigation. Both research
projects and operational industrial systems are discussed
The demand for money in developing countries: Assessing the role of financial innovation
Traditional specifications of money demand have been commonly plagU4:!d
by persistent overprediction, implausible parameter estimates, and highly
autocorrelated errors. This paper argues that some of those problems stem
from the failure to account for the impact of financial innovation. We
estimate money demand for ten developing countries employing various proxies
for the innovation process and provide an assessment of the relative
importance of this variable. We find that financial innovation plays an
important role in determining money demand and its fluctuations, and that
the importance of this role increases with the rate of inflation.
A decision tool to adjust the prescribed dose after change in the dose calculation algorithm
Purpose: This work aims to introduce a method to quantify and assess the differences in monitor unites MUs when changing to new dose calculation software that uses a different algorithm, and to evaluate the need and extent of adjustment of the prescribed dose to maintain the same clinical results. Methods: Doses were calculated using two classical algorithms based on the Pencil Beam Convolution PBC model, using 6 patients presenting lung cancers. For each patient, 3 treatment plans were generated: Plan 1 was calculated using reference algorithm PBC without heterogeneity correction, Plan 2 was calculated using test algorithm with heterogeneity correction, and in plan 3 the dose was recalculated using test algorithm and monitor unites MUs obtained from plan 1 as input. To assess the differences in the calculated MUs, isocenter dose, and spatial dose distributions using a gamma index were compared. Statistical analysis was based on a Wilcoxon signed rank test. Results: The test algorithm in plan 2 calculated significantly less MUs than reference algorithm in plan 1 by on average 5%, (p < 0.001). We also found underestimating dose for target volumes using 3D gamma index analysis. In this example, in order to obtain the same clinical outcomes with the two algorithms the prescribed dose should be adjusted by 5%.Conclusion: This method provides a quantitative evaluation of the differences between two dose calculation algorithms and the consequences on the prescribed dose. It could be used to adjust the prescribed dose when changing calculation software to maintain the same clinical results as obtained with the former software. In particular, the gamma evaluation could be applied to any situation where changes in the dose calculation occur in radiotherapy
A quantitative method to implement and to assess the single isocenter technique for breast cancer radiation therapy
Purpose: We propose a process of quality assurance to validate and implement the single isocenter technique for breast cancer radiotherapy. We evaluated the dosimetric and temporal gains using the single isocenter technique compared to classic source to skin distance (SSD) technique. Methods: 6 patients of breast cancer localization were studied. For each patient 2 treatment plans were generated. In plan 1 the dose was calculated using SSD technique. In plan 2 the dose was calculated using single isocenter technique. To implement the plan 2 a dosimetric analysis including monitor units (MU), isodose curves, cumulative and differential dose volume histograms cDVH, dDVH respectively, coverage index, conformity index for planning target volume were used. The measurements using a PMMA phantom consist of measuring point dose by an ionization chamber and 2D dose distributions using 2D diodes arrays. Wilcoxon signed rank and Spearmanâs tests were used to calculate p-value and correlation coefficient, respectively.Results: The single isocenter technique reduced the MU by average on -30.1 ± 13.6%, (p = 0.03). We observed an improvement with statistical significance between the two techniques for the mean dose, minimum dose and volume receiving 95% of the prescribed dose without over-dosage. The analysis for dDVH showed that the dose distribution in the target volume calculated in the single isocenter technique is more homogeneous than the SSD technique. Wilcoxon test showed that the two treatment plans had the same quality (p > 0.05). The difference between calculated and measured dose was within 2.4 ± 3.3% for absolute point dose and the percentage of points passing gamma criteria was on average 99.8 ± 0.2%. Conclusion: This method provides a quantitative evaluation and comparison of the two irradiation techniques for breast cancer and the consequences of the technical change on dose calculation
The origin of the high electrochemical activity of pseudo-amorphous iridium oxides
The origins of the superior catalytic activity of poorly crystallized Ir-based oxide material for the OER in acid is still under debate. Here, authors synthesize porous IrMo oxides to deconvolute the effect of Ir oxidation state from short-range ordering and show the latter to be a key factor
- âŠ