7 research outputs found

    Development and characterization of soluplus® nanomicelles associated to specific igg as an innovative strategy for the detection and neutralization of shiga toxin type 2

    Get PDF
    Shiga toxin type 2 (Stx2) is the main virulence factor of Shiga toxinproducing Escherichia coli and is responsible for triggering HemolyticUremic Syndrome (HUS). We aimed to develop and characterizepolymeric nanomicelles (PN) with the amphiphilic polymerSoluplus® coupled to anti-Stx2 IgG in order to introduce innovativeproposals for the detection of Stx2 and treatment of HUS. PN ofSoluplus® were formulated in PBS and coupled with IgG anti Stx2from hyperimmune (PN-IgG-Stx2) or control bovine colostrum (PNIgG-Ctrl). The hydrodynamic size of PN, PN-IgG-Stx2 and PN-IgGCtrlwas evaluated by Dynamic Light Scattering. Morphology of PNor PN-IgG-Stx2 was analyzed by Transmission Electron Microscopy(TEM). The PN toxicity was evaluated on both Vero and Human GlomerularEndothelial cells (HGEC) and cell viability was determinedby neutral red uptake. After coupling PN with IgG, Stx2 neutralizationcapacity of PN-IgG-Stx2 or PN-IgG-Ctrl was evaluated on Vero andHGEC cells and the percentage of cell viability was analyzed. Thehydrodynamic size of the PN of Soluplus® and IgG-Stx2 showed anaverage diameter of 70.2 ± 1.5 nm and 40.9 ± 2 nm, respectively.When both components were coupled, a single peak with a similarhydrodynamic size of the PN was observed (70.4 ± 0.2 nm). TEManalysis revealed circular particles with a diameter corresponding to100 nm either in PN and PN-IgG-Stx2 particles. PN-IgG-Stx2 wereable to neutralize Stx2 on Vero and HGEC cells in a dose dependentmanner. When comparing the neutralization capacity of Stx2 by IgGStx2vs PN-IgG-Stx2 a significant improvement in the cell viabilityof Vero and HGEC was observed with the PN-IgG-Stx2 (p<0.001).The association between anti-Stx2 IgG from bovine colostrum andSoluplus® PN was optimized and characterized. Encouraging resultsof antibody functionality coupled with PN were registered.These results may open the perspective of the design of new nanoplatformsfor neutralization and/or detection of Stx2.Fil: Girón Reyes, Claudio Daniel. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Fisiología y Biofísica Bernardo Houssay. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Fisiología y Biofísica Bernardo Houssay; ArgentinaFil: Gomez, Fernando Daniel. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Fisiología y Biofísica Bernardo Houssay. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Fisiología y Biofísica Bernardo Houssay; ArgentinaFil: Amaral, María Marta. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Fisiología y Biofísica Bernardo Houssay. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Fisiología y Biofísica Bernardo Houssay; ArgentinaFil: Chiappetta, Diego Andrés. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Departamento de Tecnología Farmacéutica; ArgentinaFil: Moretton, Marcela Analía. Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Departamento de Tecnología Farmacéutica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Ibarra, Cristina Adriana. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Fisiología y Biofísica Bernardo Houssay. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Fisiología y Biofísica Bernardo Houssay; ArgentinaFil: Sacerdoti, Flavia. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Fisiología y Biofísica Bernardo Houssay. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Fisiología y Biofísica Bernardo Houssay; ArgentinaLXVI Reunión Anual de la Sociedad Argentina de Investigación Clínica; LXIX Reunión Anual de la Sociedad Argentina de Inmunología; LIII Reunión Anual de la Asociación Argentina de Farmacología Experimental y XI Reunión Anual de la Asociación Argentina de NanomedicinasArgentinaSociedad Argentina de Investigación ClínicaSociedad Argentina de InmunologíaAsociación Argentina de Farmacología ExperimentalAsociación Argentina de Nanomedicina

    Reseñas

    Get PDF

    Tifus murino en el Cairo-valle ¿Brote o condición endémica emergente?

    Get PDF
    Introducción: En el Municipio de El Cairo Valle se reportó un brote de Tifus Murino, el cual habitualmente no se diagnostica en la región.Métodos: Se presenta una serie de casos obtenidos del Sitema de Vigilancia Epidemiológica del Municipio de El Cairo, administrado por el Hospital Municipal. Resultados: Se reportan 34 casos nuevos de Tifus Murino, que como características especiales fueron predominantemente femeninos, y población adulta. Conclusión: El brote fue controlado con la oportuna intervención del Comité de Vigilancia Epidemiológica del Municipio y coordinado por diferentes instituciones.AbstractIntroduction: El Cairo is a town in Valle, Murine Typhus is not ommonly diagnosed, a shot was reported in this region by information systems.Methods: Some cases have been taken from the Municipal Epidemiological Vigilance System in El Cairo, Valley which is administered by the Local Hospital Results: Thirty- four new cases of Murine Typhus were reported having all of them a predominant characteristic; they were found in female and adult population.Conclusion: The outbreak was controlled as a result of the appropiate intervention from the Municipal Epidemiological Vigilance Committee and the coordinated work from some institutions.Key words: Typhus Endemic Flea - Borne; Epidemiologic Surveillance; Zoonoses; Ectoparasitic Infestation

    Tifus murino en el cairo-valle ¿brote o condición endémica emergente?

    Get PDF
    En el Municipio de El Cairo Valle se reportó un brote de Tifus Murino, el cual habitualmente no se diagnostica en la región. Se presenta una serie de casos obtenidos del Sistema de Vigilancia Epidemiológica del Municipio de El Cairo, administrado por el Hospital Municipal

    Interfaz audiovisual de acceso a las TICs a personas con limitaciones motrices.

    No full text
    La creciente capacidad de cálculo junto con la disminución en costo ha masificado el uso de los computadores en las más diversas tareas de la humanidad Desde su creación los computadores y aplicaciones fueron concebidos para personas sin limitaciones psicofisiológicas y con formas de interacción poco naturales

    Jornadas Nacionales de Robótica y Bioingeniería 2023: Libro de actas

    Full text link
    Las Jornadas de Robótica y Bioingeniería de 2023 tienen lugar en la Escuela Técnica Superior de Ingeniería Industrial de la Universidad Politécnica de IVIadrid, entre los días 14 y 16 de junio de 2023. En este evento propiciado por el Comité Español de Automática (CEA) tiene lugar la celebración conjunta de las XII Jornadas Nacionales de Robótica y el XIV Simposio CEA de Bioingeniería. Las Jornadas Nacionales de Robótica es un evento promovido por el Grupo Temático de Robótica (GTRob) de CEA para dar visibilidad y mostrar las actividades desarrolladas en el ámbito de la investigación y transferencia tecnológica en robótica. Asimismo, el propósito de Simposio de Bioingeniería, que cumple ahora su decimocuarta dicción, es el de proporcionar un espacio de encuentro entre investigadores, desabolladores, personal clínico, alumnos, industriales, profesionales en general e incluso usuarios que realicen su actividad en el ámbito de la bioingeniería. Estos eventos se han celebrado de forma conjunta en la anualidad 2023. Esto ha permitido aunar y congregar un elevado número de participantes tanto de la temática robótica como de bioingeniería (investigadores, profesores, desabolladores y profesionales en general), que ha posibilitado establecer puntos de encuentro, sinergias y colaboraciones entre ambos. El programa de las jornadas aúna comunicaciones científicas de los últimos resultados de investigación obtenidos, por los grupos a nivel español más representativos dentro de la temática de robótica y bioingeniería, así como mesas redondas y conferencias en las que se debatirán los temas de mayor interés en la actualidad. En relación con las comunicaciones científicas presentadas al evento, se ha recibido un total de 46 ponencias, lo que sin duda alguna refleja el alto interés de la comunidad científica en las Jornadas de Robótica y Bioingeniería. Estos trabajos serán expuestos y presentados a lo largo de un total de 10 sesiones, distribuidas durante los diferentes días de las Jornadas. Las temáticas de los trabajos cubren los principales retos científicos relacionados con la robótica y la bioingeniería: robótica aérea, submarina, terrestre, percepción del entorno, manipulación, robótica social, robótica médica, teleoperación, procesamiento de señales biológicos, neurorehabilitación etc. Confiamos, y estamos seguros de ello, que el desarrollo de las jornadas sea completamente productivo no solo para los participantes en las Jornadas que podrán establecer nuevos lazos y relaciones fructíferas entre los diferentes grupos, sino también aquellos investigadores que no hayan podido asistir. Este documento que integra y recoge todas las comunicaciones científicas permitirá un análisis más detallado de cada una de las mismas

    ENGIU: Encuentro Nacional de Grupos de Investigación de UNIMINUTO.

    No full text
    El desarrollo del prototipo para el sistema de detección de Mina Antipersona (MAP), inicia desde el semillero ADSSOF perteneciente al programa de Administración en Seguridad y Salud en el trabajo de la UNIMINUTO, se realiza a partir de un detector de metales que emite una señal audible, que el usuario puede interpretar como aviso de presencia de un objeto metálico, en este caso una MAP. La señal audible se interpreta como un dato, como ese dato no es perceptible a 5 metros de distancia, se implementa el transmisor de Frecuencia Modulada FM por la facilidad de modulación y la escogencia de frecuencia de transmisión de acuerdo con las normas y resolución del Ministerio de Comunicaciones; de manera que esta sea la plataforma base para enviar los datos obtenidos a una frecuencia establecida. La idea es que el ser humano no explore zonas peligrosas y buscar la forma de crear un sistema que permita eliminar ese riesgo, por otro lado, buscar la facilidad de uso de elementos ya disponibles en el mercado
    corecore