241 research outputs found

    Energy retrofit interventions in historic buildings: exploring guidance and attitudes of conservation professionals to slim double glazing in the UK

    Get PDF
    The file attached to this record is the author's final peer reviewed version. The Publisher's final version can be found by following the DOI link

    The Role of Adenosine in Pulmonary Vein Isolation: A Critical Review

    Get PDF
    The cornerstone of atrial fibrillation (AF) ablation is pulmonary vein isolation (PVI), which can be achieved in more than 95% of patients at the end of the procedure. However, AF recurrence rates remain high and are related to recovery of PV conduction. Adenosine testing is used to unmask dormant pulmonary vein conduction (DC). The aim of this study is to review the available literature addressing the role of adenosine testing and determine the impact of ablation at sites of PV reconnection on freedom from AF. Adenosine infusion, by restoring the excitability threshold, unmasks reversible injury that could lead to recovery of PV conduction. The studies included in this review suggest that adenosine is useful to unmask nontransmural lesions at risk of reconnection and that further ablation at sites of DC is associated with improvement in freedom from AF. Nevertheless it has been demonstrated that adenosine is not able to predict all veins at risk of later reconnection, which means that veins without DC are not necessarily at low risk. The role of the waiting period in the setting of adenosine testing has also been analyzed, suggesting that in the acute phase adenosine use should be accompanied by enough waiting time

    Therapeutic benefits of distal ventricular pacing in mid-cavity obstructive hypertrophic cardiomyopathy.

    Get PDF
    INTRODUCTION: Hypertrophic cardiomyopathy (HCM) patients with left ventricular (LV) mid-cavity obstruction (LVMCO) often experience severe drug-refractory symptoms thought to be related to intraventricular obstruction. We tested whether ventricular pacing, guided by invasive haemodynamic assessment, reduced LVMCO and improved refractory symptoms. METHODS: Between December 2008 and December 2017, 16 HCM patients with severe refractory symptoms and LVMCO underwent device implantation with haemodynamic pacing study to assess the effect on invasively defined LVMCO gradients. The effect on the gradient of atrioventricular (AV) synchronous pacing from sites including right ventricular (RV) apex and middle cardiac vein (MCV) was retrospectively assessed. RESULTS: Invasive haemodynamic data were available in 14 of 16 patients. Mean pre-treatment intracavitary gradient was 77 ± 22 mmHg (in sinus rhythm) versus 21 ± 21 mmHg during pacing from optimal ventricular site (95% CI: -70.86 to -40.57, p < 0.0001). Optimal pacing site was distal MCV in 12/16 (86%), RV apex in 1/16 and via epicardial LV lead in 1/16. Pre-pacing Doppler-derived gradients were significantly higher than at follow-up (47 ± 15 versus 24 ± 16 mmHg, 95% CI: -37.19 to -13.73, p < 0.001). Median baseline NYHA class was 3, which had improved by ⩾1 NYHA class in 13 of 16 patients at 1-year post-procedure (p < 0.001). The mean follow-up duration was 4.6 ± 2.7 years with the following outcomes: 8/16 (50%) had continued symptomatic improvement, 4/16 had symptomatic decline and 4/16 died. Contributors to symptomatic decline included chronic atrial fibrillation (AF) (n = 5), phrenic nerve stimulation (n = 3) and ventricular ectopy (n = 1). CONCLUSION: In drug-refractory symptomatic LVMCO, distal ventricular pacing can reduce intracavitary obstruction and may provide long-term symptomatic relief in patients with limited treatment options. A haemodynamic pacing study is an effective strategy for identifying optimal pacing site and configuration

    A subject-specific technique for respiratory motion correction in image-guided cardiac catheterisation procedures

    Get PDF
    We describe a system for respiratory motion correction of MRI-derived roadmaps for use in X-ray guided cardiac catheterisation procedures. The technique uses a subject-specific affine motion model that is quickly constructed from a short pre-procedure MRI scan. We test a dynamic MRI sequence that acquires a small number of high resolution slices, rather than a single low resolution volume. Additionally, we use prior knowledge of the nature of cardiac respiratory motion by constraining the model to use only the dominant modes of motion. During the procedure the motion of the diaphragm is tracked in X-ray fluoroscopy images, allowing the roadmap to be updated using the motion model. X-ray image acquisition is cardiac gated. Validation is performed on four volunteer datasets and three patient datasets. The accuracy of the model in 3D was within 5 mm in 97.6% of volunteer validations. For the patients, 2D accuracy was improved from 5 to 13 mm before applying the model to 2–4 mm afterwards. For the dynamic MRI sequence comparison, the highest errors were found when using the low resolution volume sequence with an unconstrained model

    Cardiac resynchronization therapy: mechanisms of action and scope for further improvement in cardiac function.

    Get PDF
    Aims: Cardiac resynchronization therapy (CRT) may exert its beneficial haemodynamic effect by improving ventricular synchrony and improving atrioventricular (AV) timing. The aim of this study was to establish the relative importance of the mechanisms through which CRT improves cardiac function and explore the potential for additional improvements with improved ventricular resynchronization. Methods and Results: We performed simulations using the CircAdapt haemodynamic model and performed haemodynamic measurements while adjusting AV delay, at low and high heart rates, in 87 patients with CRT devices. We assessed QRS duration, presence of fusion, and haemodynamic response. The simulations suggest that intrinsic PR interval and the magnitude of reduction in ventricular activation determine the relative importance of the mechanisms of benefit. For example, if PR interval is 201 ms and LV activation time is reduced by 25 ms (typical for current CRT methods), then AV delay optimization is responsible for 69% of overall improvement. Reducing LV activation time by an additional 25 ms produced an additional 2.6 mmHg increase in blood pressure (30% of effect size observed with current CRT). In the clinical population, ventricular fusion significantly shortened QRS duration (Δ-27 ± 23 ms, P < 0.001) and improved systolic blood pressure (mean 2.5 mmHg increase). Ventricular fusion was present in 69% of patients, yet in 40% of patients with fusion, shortening AV delay (to a delay where fusion was not present) produced the optimal haemodynamic response. Conclusions: Improving LV preloading by shortening AV delay is an important mechanism through which cardiac function is improved with CRT. There is substantial scope for further improvement if methods for delivering more efficient ventricular resynchronization can be developed. Clinical Trial Registration: Our clinical data were obtained from a subpopulation of the British Randomised Controlled Trial of AV and VV Optimisation (BRAVO), which is a registered clinical trial with unique identifier: NCT01258829, https://clinicaltrials.gov
    • …
    corecore