2,523 research outputs found

    Characterization of the monocyte-specific esterase (MSE) gene

    Get PDF
    Carboxylic esterases are widely distributed in hematopoietic cells. Monocytes express the esterase isoenzyme (termed 'monocyte-specific esterase', MSE) that can be inhibited by NaF in the alpha-naphthyl acetate cytochemical staining. We examined the expression of MSE in normal cells and primary and cultured leukemia-lymphoma cells. The MSE protein was demonstrated by isoelectric focusing (IEF); MSE mRNA expression was investigated by Northern blotting and reverse transcriptase-polymerase chain reaction (RT-PCR). The following samples were positive for MSE protein and Northern mRNA expression: 20/24 monocytic, 4/32 myeloid, and 1/20 erythroid-megakaryocytic leukemia cell lines, but none of the 112 lymphoid leukemia or lymphoma cell lines; of the normal purified cell populations only the monocytes were positive whereas, T, B cells, and granulocytes were negative; of primary acute (myelo) monocytic leukemia cells (CD14-positive, FAB M4/M5 morphology) 14/20 were Northern mRNA and 11/14 IEF protein positive. RT-PCR revealed MSE expression in 29/49 Northern-negative lymphoid leukemia-lymphoma cell lines. The RT-PCR signals in monocytic cell lines were on average 50-fold stronger than the mostly weak trace expression in lymphoid specimens. On treatment with various biomodulators, only all-trans retinoic acid significantly upregulated MSE message and protein levels but could not induce new MSE expression in several leukemia cell lines; lipopolysaccharide and interferon-gamma increased MSE expression in normal monocytes. Analysis of DNA methylation with sensitive restriction enzymes showed no apparent regulation of gene expression by differential methylation; the MSE gene is evolutionarily conserved among mammalian species; the half-life of the human MSE transcripts was about 5-6 h. The extent of MSE expression varied greatly among different monocytic leukemia samples. However, the MSE overexpression in a significant number of specimens was not associated with gene amplification, gross structural rearrangements or point mutations within the cDNA region. Taken together, the results suggest that MSE expression is not absolutely specific for, but strongly associated with cells of the monocytic lineage; MSE is either not expressed at all or expressed at much lower levels in cells from other lineages. The biological significance, if any, of rare MSE messages in lymphoid cells detectable only by the hypersensitive RT-PCR remains unclear. Further studies on the regulation of this gene and on the physiological function of the enzyme will no doubt be informative with respect to its striking overexpression in some malignant cells and to a possible role in the pathobiology of monocytic leukemias

    Tension at the borders: perceptions of role overload, conflict, strain and facilitation in work, family and health roles among employed individuals with arthritis

    Get PDF
    Objective. To examine inter-relationships among arthritis (A), work (W) and personal life (P) roles and their reciprocal influences, especially experiences of role balance/imbalance among individuals with inflammatory arthritis (IA) and OA

    The effect on work presenteeism of job retention vocational rehabilitation compared to a written self-help work advice pack for employed people with inflammatory arthritis: protocol for a multi-centre randomised controlled trial (the WORKWELL trial)

    Get PDF
    Abstract: Background: Work problems are common in people with inflammatory arthritis. Up to 50% stop work within 10 years due to their condition and up to 67% report presenteeism (i.e. reduced work productivity), even amongst those with low disease activity. Job retention vocational rehabilitation (JRVR) may help prevent or postpone job loss and reduce presenteeism through work assessment, work-related rehabilitation and enabling job accommodations. This aims to create a better match between the person’s abilities and their job demands. The objectives of the Workwell trial are to test the overall effectiveness and cost-effectiveness of JRVR (WORKWELL) provided by additionally trained National Health Service (NHS) occupational therapists compared to a control group who receive self-help information both in addition to usual care. Methods: Based on the learning from a feasibility trial (the WORK-IA trial: ISRCTN76777720), the WORKWELL trial is a multi-centre, pragmatic, individually-randomised parallel group superiority trial, including economic evaluation, contextual factors analysis and process evaluation. Two hundred forty employed adults with rheumatoid arthritis, undifferentiated inflammatory arthritis or psoriatic arthritis (in secondary care), aged 18 years or older with work instability will be randomised to one of two groups: a self-help written work advice pack plus usual care (control intervention); or WORKWELL JRVR plus a self-help written work advice pack and usual care. WORKWELL will be delivered by occupational therapists provided with additional JRVR training from the research team. The primary outcome is presenteeism as measured using the Work Limitations Questionnaire-25. A comprehensive range of secondary outcomes of work, health, contextual factors and health resource use are included. Outcomes are measured at 6- and 12- months (with 12-months as the primary end-point). A multi-perspective within-trial cost-effectiveness analyses will also be conducted. Discussion: This trial will contribute to the evidence base for provision of JRVR to people with inflammatory arthritis. If JRVR is found to be effective in enabling people to keep working, the findings will support decision-making about provision of JRVR by rheumatology teams, therapy services and healthcare commissioners, and providing evidence of the effectiveness of JRVR and the economic impact of its implementation. Trial registration: Clinical Trials.Gov: NCT03942783. Registered 08/05/2019 (https://clinicaltrials.gov/ct2/show/NCT03942783); ISRCTN Registry: ISRCTN61762297. Registered:13/05/2019 (http://www.isrctn.com/ISRCTN61762297). Retrospectively registered

    A randomized controlled trial of high-intensity exercise and executive functioning in cognitively normal older adults

    Get PDF
    Background There is a paucity of interventional research that systematically assesses the role of exercise intensity and cardiorespiratory fitness, and their relationship with executive function in older adults. To address this limitation, we have examined the effect of a systematically manipulated exercise intervention on executive function. Methods Ninety-nine cognitively normal participants (age = 69.10 ± 5.2 years; n = 54 female) were randomized into either a high-intensity cycle-based exercise, moderate-intensity cycle-based exercise, or no-intervention control group. All participants underwent neuropsychological testing and fitness assessment at baseline (preintervention), 6-month follow-up (postintervention), and 12-month postintervention. Executive function was measured comprehensively, including measures of each subdomain: Shifting, Updating/ Working Memory, Inhibition, Verbal Generativity, and Nonverbal Reasoning. Cardiorespiratory fitness was measured by analysis of peak aerobic capacity; VO2peak. Results First, the exercise intervention was found to increase cardiorespiratory fitness (VO2peak) in the intervention groups, in comparison to the control group (F =10.40, p≤0.01). However, the authors failed to find mean differences in executive function scores between the high-intensity, moderate intensity, or inactive control group. On the basis of change scores, cardiorespiratory fitness was found to associate positively with the executive function (EF) subdomains of Updating/Working Memory (β = 0.37, p = 0.01, r = 0.34) and Verbal Generativity (β = 0.30, p = 0.03, r = 0.28) for intervention, but not control participants. Conclusion At the aggregate level, the authors failed to find evidence that 6-months of high-intensity aerobic exercise improves EF in older adults. However, it remains possible that individual differences in experimentally induced changes in cardiorespiratory fitness may be associated with changes in Updating/ Working Memory and Verbal Generativity

    Stable ultrahigh-density magneto-optical recordings using introduced linear defects

    Full text link
    The stability of data bits in magnetic recording media at ultrahigh densities is compromised by thermal `flips' -- magnetic spin reversals -- of nano-sized spin domains, which erase the stored information. Media that are magnetized perpendicular to the plane of the film, such as ultrathin cobalt films or multilayered structures, are more stable against thermal self-erasure than conventional memory devices. In this context, magneto-optical memories seem particularly promising for ultrahigh-density recording on portable disks, and bit densities of ∼\sim100 Gbit inch−2^{-2} have been demonstrated using recent advances in the bit writing and reading techniques. But the roughness and mobility of the magnetic domain walls prevents closer packing of the magnetic bits, and therefore presents a challenge to reaching even higher bit densities. Here we report that the strain imposed by a linear defect in a magnetic thin film can smooth rough domain walls over regions hundreds of micrometers in size, and halt their motion. A scaling analysis of this process, based on the generic physics of disorder-controlled elastic lines, points to a simple way by which magnetic media might be prepared that can store data at densities in excess of 1 Tbit inch−2^{-2}.Comment: 5 pages, 4 figures, see also an article in TRN News at http://www.trnmag.com/Stories/041801/Defects_boost_disc_capacity_041801.htm

    COVID-19 outbreak and increased risk of amblyopia and epidemic myopia: Insights from EUROCOVCAT group

    Get PDF
    The most common cause of vision impairment in children is amblyopia. It is defined as impaired visual acuity in one or both eyes that is present with no demonstrable abnormality of the visual pathway and is not immediately resolved by wearing glasses. After the World Health Organization (WHO) recognized COVID-19 as a global pandemic on March 11, 2020, widespread changes and restrictions to social and sanitary practices have presented significant issues in access to eye care during the COVID-19 pandemic. A reduction of more than 80% in pediatric eye care volume up to its total cessation has been observed in different departments. In this scenario, reduced or absent eyesight, due to delay in timely treatment of amblyopic conditions, could create major, long-lasting effects on all aspects of life, including daily personal activities, interacting with the community, school and work opportunities and the ability to access public services. Processes coming out of lockdown should be gradually easing restrictions giving priority to ophthalmology and eye care facilities so that amblyopia does not remain unattended and irreversible as in adults due to lack of timely treatments. If not reversible, this process could lead to a dramatic increase in disability and unsustainable social costs for many governments

    The three-dimensional easy morphological (3-DEMO) classification of scoliosis, part II: repeatability

    Get PDF
    BACKGROUND: In the first part of this study we proposed a new classification approach for spinal deformities (3-DEMO). To be valid, a classification needs to overcome the repeatability issue which is inherent both in the used classificatory system and in the measured object. AIM: The aim of this study is to present procedures and results obtained within the repeatability of 3-DEMO classification for scoliosis analysis. METHOD: We acquired the data of 100 pathological and 20 normal spines with an optoelectronic system (AUSCAN) and of two dummies with simulated spine deformity. On the obtained 3D reconstruction of the spine, we considered the coronal view with a spinal reference system (Top View) and its three related parameters, defined in part I, constituting the 3-DEMO classification. We calculated the repeatability coefficient for the subjects (two acquisitions for each subject with a time interval of 26 ± 12 sec), whereas we evaluated the system measurement error calculating the standard deviation of 50 consecutive acquisitions for each dummy. RESULTS: Comparing the results of the two types of acquisition, it emerged that the main part of parameters variability was due to postural adjustments The proportion of agreement for the 3-DEMO parameters gives a k value above 0.8; almost 10% of patients changed classification because of postural adjustments, but none had a "mirror-like" variation nor a change in more of one parameter at a time Repeatability coefficient is lower than the previously calculated normative limits. DISCUSSION: The 3-DEMO classification has a high repeatability when evaluated with an optoelectronic system such as the AUSCAN System, whose systematic error is very low. This means that the implied physiological phenomenon is consistent and overcomes the postural variability inherent in the measured object (normal or pathological subject)
    • …
    corecore