760 research outputs found

    Position clamping of optically trapped microscopic non-spherical probes

    Get PDF
    We investigate the degree of control that can be exercised over an optically trapped microscopic non-spherical force probe. By position clamping translational and rotational modes in different ways, we are able to dramatically improve the position resolution of our probe with no reduction in sensitivity. We also demonstrate control over rotational-translational coupling, and exhibit a mechanism whereby the average centre of rotation of the probe can be displaced away from its centre

    A compact holographic optical tweezers instrument

    Get PDF
    Holographic optical tweezers have found many applications including the construction of complex micron-scale 3D structures and the control of tools and probes for position, force, and viscosity measurement. We have developed a compact, stable, holographic optical tweezers instrument which can be easily transported and is compatible with a wide range of microscopy techniques, making it a valuable tool for collaborative research. The instrument measures approximately 30Ă—30Ă—35 cm and is designed around a custom inverted microscope, incorporating a fibre laser operating at 1070 nm. We designed the control software to be easily accessible for the non-specialist, and have further improved its ease of use with a multi-touch iPad interface. A high-speed camera allows multiple trapped objects to be tracked simultaneously. We demonstrate that the compact instrument is stable to 0.5 nm for a 10 s measurement time by plotting the Allan variance of the measured position of a trapped 2 ÎĽm silica bead. We also present a range of objects that have been successfully manipulated

    Optical trapping at gigapascal pressures

    Get PDF
    Diamond anvil cells allow the behavior of materials to be studied at pressures up to hundreds of gigapascals in a small and convenient instrument. However, physical access to the sample is impossible once it is pressurized. We show that optical tweezers can be used to hold and manipulate particles in such a cell, confining micron-sized transparent beads in the focus of a laser beam. Here, we use a modified optical tweezers geometry, allowing us to trap through an objective lens with a higher working distance, overcoming the constraints imposed by the limited angular acceptance of the anvil cell. We demonstrate the effectiveness of the technique by measuring water’s viscosity at pressures of up to 1.3 GPa. In contrast to previous viscosity measurements in anvil cells, our technique measures absolute viscosity and does not require scaling to the accepted value at atmospheric pressure. This method could also measure the frequency dependence of viscosity as well as being sensitive to anisotropy in the medium’s viscosity

    Constructing 3D crystal templates for photonic band gap materials using holographic optical tweezers

    Get PDF
    A simple and robust method is presented for the construction of 3-dimensional crystals from silica and polystyrene microspheres. The crystals are suitable for use as templates in the production of three-dimensional photonic band gap (PBG) materials. Manipulation of the microspheres was achieved using a dynamic holographic assembler (DHA) consisting of computer controlled holographic optical tweezers. Attachment of the microspheres was achieved by adjusting their colloidal interactions during assembly. The method is demonstrated by constructing a variety of 3-dimensional crystals using spheres ranging in size from 3 µm down to 800 nm. A major advantage of the technique is that it may be used to build structures that cannot be made using self-assembly. This is illustrated through the construction of crystals in which line defects have been deliberately included, and by building simple cubic structures

    A multi-modal stereo microscope based on a spatial light modulator

    Get PDF
    Spatial Light Modulators (SLMs) can emulate the classic microscopy techniques, including differential interference (DIC) contrast and (spiral) phase contrast. Their programmability entails the benefit of flexibility or the option to multiplex images, for single-shot quantitative imaging or for simultaneous multi-plane imaging (depth-of-field multiplexing). We report the development of a microscope sharing many of the previously demonstrated capabilities, within a holographic implementation of a stereo microscope. Furthermore, we use the SLM to combine stereo microscopy with a refocusing filter and with a darkfield filter. The instrument is built around a custom inverted microscope and equipped with an SLM which gives various imaging modes laterally displaced on the same camera chip. In addition, there is a wide angle camera for visualisation of a larger region of the sample

    A Process and Outcome Evaluation of a Shelter for Homeless Young Women

    Get PDF
    To evaluate the processes and outcomes of a short-term shelter, both quantitative and qualitative data were gathered via participant observation, focus group interviews with shelter staff and residents, and individual interviews with a sample of 40 young women who had been homeless prior to using the shelter. The process evaluation showed that the shelter staff strived to utilize an empowerment philosophy in their relationships with residents, but that there were many challenges to implementing this philosophy. The outcome evaluation showed that, at a 3-month follow-up, the participants reported significant improvements in housing, income, independence, and life satisfaction, but most continued to experience poverty and a number of other difficulties. The results were discussed in terms of the implications for future research and the value and limitations of shelters for dealing with homeless youth. The need for more sustained and comprehensive program interventions and supportive social policies was underscored

    The Influence of an Orienting Task on the Memory Performance of Children with Reading Problems

    Full text link
    This study investigated the hypothesis that differences in performance between reading disabled and normal children on a rote memory task could be eliminated if both groups were induced to process the material to be remembered in the same manner. The free recall of fourth-grade good and poor readers was tested following a free study period and the performance of an orienting task that required subjects to sort the material into taxonomic categories. There was a significant group by conditions interaction, with recall differences in the free study condition being eliminated following performance of the orienting task. The results have important implications for theoretical explanations of performance deficits in reading disabled children.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/68893/2/10.1177_002221947901200608.pd

    PLOS Genetics Data Sharing Policy: In Pursuit of Functional Utility

    Get PDF
    About a year ago, PLOS implemented a new process intended to further the overarching principle that data used in the work we publish should be accessible and reusable. The motivation goes hand-in-hand with both our open access ethos and the scientific method itself: the validity of a conclusion depends on the ability to reproduce the underlying results

    Impact of post-transplantation maintenance therapy on health-related quality of life in patients with multiple myeloma: data from the Connect® MM Registry

    Get PDF
    Maintenance therapy after autologous stem cell transplantation (ASCT) is recommended for use in multiple myeloma (MM); however, more data are needed on its impact on health-related quality of life (HRQoL). Presented here is an analysis of HRQoL in a Connect MM registry cohort of patients who received ASCT ± maintenance therapy. The Connect MM Registry is one of the earliest and largest, active, observational, prospective US registry of patients with symptomatic newly diagnosed MM. Patients completed the Functional Assessment of Cancer Therapy-MM (FACT-MM) version 4, EuroQol-5D (EQ-5D) questionnaire, and Brief Pain Inventory (BPI) at study entry and quarterly thereafter until death or study discontinuation. Patients in three groups were analyzed: any maintenance therapy (n = 244), lenalidomide-only maintenance therapy (n = 169), and no maintenance therapy (n = 137); any maintenance and lenalidomide-only maintenance groups were not mutually exclusive. There were no significant differences in change from pre-ASCT baseline between any maintenance (P = 0.60) and lenalidomide-only maintenance (P = 0.72) versus no maintenance for the FACT-MM total score. There were also no significant differences in change from pre-ASCT baseline between any maintenance and lenalidomide-only maintenance versus no maintenance for EQ-5D overall index, BPI, FACT-MM Trial Outcomes Index, and myeloma subscale scores. In all three groups, FACT-MM, EQ-5D Index, and BPI scores improved after ASCT; FACT-MM and BPI scores deteriorated at disease progression. These data suggest that post-ASCT any maintenance or lenalidomide-only maintenance does not negatively impact patients' HRQoL. Additional research is needed to verify these findings
    • …
    corecore