113 research outputs found

    Titanium dioxide nanoparticles as radiosensitisers: An in vitro and phantom-based study

    Get PDF
    Objective: Radiosensitisation caused by titanium dioxide nanoparticles (TiO2-NPs) is investigated using phantoms (PRESAGE® dosimeters) and in vitro using two types of cell lines, cultured human keratinocyte (HaCaT) and prostate cancer (DU145) cells. Methods: Anatase TiO2-NPs were synthesised, characterised and functionalised to allow dispersion in culture-medium for in vitro studies and halocarbons (PRESAGE® chemical compositions). PRESAGE® dosimeters were scanned with spectrophotometer to determine the radiation dose enhancement. Clonogenic and cell viability assays were employed to determine cells survival curves from which the dose enhancement levels "radiosensitisation" are deduced. Results: Comparable levels of radiosensitisation were observed in both phantoms and cells at kilovoltage ranges of x-ray energies (slightly higher in vitro). Significant radiosensitisation (~67 %) of control was also noted in cells at megavoltage energies (commonly used in radiotherapy), compared to negligible levels detected by phantoms. This difference is attributed to biochemical effects, specifically the generation of reactive oxygen species (ROS) such as hydroxyl radicals (•OH), which are only manifested in aqueous environments of cells and are non-existent in case of phantoms. Conclusions: This research shows that TiO2-NPs improve the efficiency of dose delivery, which has implications for future radiotherapy treatments. Literature shows that Ti2O3-NPs can be used as imaging agents hence with these findings renders these NPs as theranostic agents

    Evaluating the peak-to-valley dose ratio of synchrotron microbeams using PRESAGE fluorescence

    Get PDF
    Synchrotron-generated microbeam radiotherapy holds great promise for future treatment, but the high dose gradients present conventional dosimetry with a challenge. Measuring the important peak-to-valley dose ratio (PVDR) of a microbeam-collimated synchrotron source requires both a dosimeter and an analysis method capable of exceptional spatial resolution. The PVDR is of great interest since it is the limiting factor for potential application of the microbeam radiation therapy technique clinically for its tissue-sparing properties (i.e. the valley dose should be below the tolerance of normal tissue). In this work a new method of measuring the dose response of PRESAGE dosimeters is introduced using the fluorescence from a 638 nm laser on a confocal laser-scanning microscope. This fluorescent microscopy method produces dosimetry data at a pixel size as low as 78 nm, giving a much better spatial resolution than optical computed tomography, which is normally used for scanning PRESAGE dosimeters. Using this technique the PVDR of the BL28B2 microbeam at the SPring-8 synchrotron in Japan is estimated to be approximately 52:1 at a depth of 2.5 mm. The PVDR was also estimated with EBT2 GAFchromic films as 30.5:1 at the surface in order to compare the PRESAGE fluorescent results with a more established dosimetry system. This estimation is in good agreement with previously measured ratios using other dosimeters and Monte Carlo simulations. This means that it is possible to use PRESAGE dosimeters with confocal microscopy for the determination of PVDR

    Gitelman syndrome associated with chondrocalcinosis: description of two cases

    Get PDF
    Gitelman syndrome is a rare inherited tubulopathy, characterized by hypomagnesemia, hypokalemia, metabolic alkalosis, hypocalciuria and hyperreninemic hyperaldosteronism. The clinical spectrum is wide and includes: cramps, myalgies, muscle weakness, until episodes of carpo-podalic spasm, tetania, rabdomyolisis and paralysis. Some cases have been described in literature underlining the association of this condition with chondrocalcinosis, as a typical example of hypomagnesemia-induced crystal deposition disease. The therapy of Gitelman syndrome consists on the administration of defective electrolytes, althought not always effective. We describe two cases of Gitelman syndrome associated with chondrocalcinosis showing the wide range of presentation of this clinical condition

    Polyarthritis flare in patient with ankylosing spondylitis treated with infliximab

    Get PDF
    Over the last ten years, the treatment of seronegative spondyloarthropathies has changed dramatically with the introduction of the anti-tumor necrosis factor alpha (TNFα) agents. Nevertheless, there is a growing number of studies describing several adverse reactions in patients treated with biological agents. In the present report we describe the case of a 22-year-old male patient with ankylosing spondylitis who developed a "paradoxic" adverse reaction, while receiving infliximab

    Power Doppler signal at the enthesis and bone erosions are the most discriminative OMERACT ultrasound lesions for SpA: Results from the DEUS (Defining Enthesitis on Ultrasound in Spondyloarthritis) multicentre study

    Get PDF
    Objectives To assess, in spondyloarthritis (SpA), the discriminative value of the Outcome Measures in Rheumatology (OMERACT) ultrasound lesions of enthesitis and their associations with clinical features in this population. Methods In this multicentre study involving 20 rheumatology centres, clinical and ultrasound examinations of the lower limb large entheses were performed in 413 patients with SpA (axial SpA and psoriatic arthritis) and 282 disease controls (osteoarthritis and fibromyalgia). 'Active enthesitis' was defined as (1) power Doppler (PD) at the enthesis grade ≥1 plus entheseal thickening and/or hypoechoic areas, or (2) PD grade >1 (independent of the presence of entheseal thickening and/or hypoechoic areas). Results In the univariate analysis, all OMERACT lesions except enthesophytes/calcifications showed a significant association with SpA. PD (OR=8.77, 95% CI 4.40 to 19.20, p<0.001) and bone erosions (OR=4.75, 95% CI 2.43 to 10.10, p<0.001) retained this association in the multivariate analysis. Among the lower limb entheses, only the Achilles tendon was significantly associated with SpA (OR=1.93, 95% CI 1.30 to 2.88, p<0.001) in the multivariate analyses. Active enthesitis showed a significant association with SpA (OR=9.20, 95% CI 4.21 to 23.20, p<0.001), and unlike the individual OMERACT ultrasound lesions it was consistently associated with most clinical measures of SpA disease activity and severity in the regression analyses. Conclusions This large multicentre study assessed the value of different ultrasound findings of enthesitis in SpA, identifying the most discriminative ultrasound lesions and entheseal sites for SpA. Ultrasound could differentiate between SpA-related enthesitis and other forms of entheseal pathology (ie, mechanical enthesitis), thus improving the assessment of entheseal involvement in SpA

    ROPES eye plaque dosimetry: commissioning and verification of an ophthalmic brachytherapy treatment planning system

    Get PDF
    In this study, the Plaque SimulatorTM eye plaque brachytherapy planning system was commissioned for ROPES eye plaques and Amersham Health model 6711 Iodine 125 seeds, using TG43-UI data. The brachytherapy module of the RADCALC® independent checking program was configured to allow verification of the accuracy of the dose calculated by Plaque SimulatorTM. Central axis depth dose distributions were compared and observed to agree to within 2% for all ROPES plaque models and depths of interest. Experimental measurements were performed with a customized PRESAGEm 3-D type dosimeter to validate the calculated depth dose distributions. Preliminary results have shown the effect of the stainless steel plaque backing decreases the measured fluorescence intensity by up to 25%, and 40% for the 15 mm and 10 mm diameter ROPES plaques respectively. This effect, once fully quantified should be accounted for in the Plaque SimulatorTM eye plaque brachytherapy planning system

    A gamma ray detector with lead-scintillator tiles and WLS fiber readout for the experiment at SPring-8 to study the GDH sum rule

    No full text
    A prototype gamma ray detector for the detection of ?0 in the proposed experiment at SPring-8 to study the Gerasimov-Drell-Hearn (GDH) sum rule (GDH experiment) has been built and tested. The detector is fabricated with lead-scintillator tiles and wave length shifter fiber readout. This detector will be placed inside the bore of the superconducting magnet which supplies the polarized target with a 2.5 T magnetic field. High-detection efficiency (above 85%) for the gamma rays is the most important requirement for this detector to be employed in the proposed experiment. It has been tested with minimum ionizing particles, electrons and gamma rays. The results of the tests in comparison with some Monte Carlo simulations are presented. The evaluated efficiency for gamma rays ranging in energy above 50 MeV is higher than 90%
    • …