40 research outputs found

    Wavelength-selected Neutron Pulses Formed by a Spatial Magnetic Neutron Spin Resonator

    Get PDF
    AbstractWe present a novel type of spatial magnetic neutron spin resonator whose time and wavelength resolution can be de- coupled from each other by means of a travelling wave mode of operation. Combined with a pair of highly efficient polarisers such a device could act simultaneously as monochromator and chopper, able to produce short neutron pulses, whose wavelength, spectral width and duration could be varied almost instantaneously by purely electronic means with- out any mechanical modification of the experimental setup. To demonstrate the practical feasibility of this technique we have designed and built a first prototype resonator consisting of ten individually switchable modules which allows to produce neutron pulses in the microsecond regime. It was installed at a polarised 2.6Å neutron beamline at the 250kW TRIGA research reactor of the Vienna University of Technology where it could deliver pulses of 55μs duration, which is about three times less than the passage time of the neutrons through the resonator itself. In order to further improve the achievable wavelength resolution to about 3% a second prototype resonator, consisting of 48 individual modules with optimised field homogeneity and enlarged beam cross-section of 6 × 6cm2 was developed. We present the results of first measurements which demonstrate the successful operation of this device

    Optimal parameters for radiation reaction experiments

    Get PDF
    As new laser facilities are developed with intensities on the scale of 10^22 - 10^24 W cm^-2 , it becomes ever more important to understand the effect of strong field quantum electrodynamics processes, such as quantum radiation reaction, which will play a dominant role in laser-plasma interactions at these intensities. Recent all-optical experiments, where GeV electrons from a laser wakefield accelerator encountered a counter-propagating laser pulse with a_0 > 10, have produced evidence of radiation reaction, but have not conclusively identified quantum effects nor their most suitable theoretical description. Here we show the number of collisions and the conditions required to accomplish this, based on a simulation campaign of radiation reaction experiments under realistic conditions. We conclude that while the critical energy of the photon spectrum distinguishes classical and quantum-corrected models, a better means of distinguishing the stochastic and deterministic quantum models is the change in the electron energy spread. This is robust against shot-to-shot fluctuations and the necessary laser intensity and electron beam energies are already available. For example, we show that so long as the electron energy spread is below 25%, collisions at a_0 = 10 with electron energies of 500 MeV could differentiate between different quantum models in under 30 shots, even with shot to shot variations at the 50% level.Comment: 12 pages, 7 figure

    Experimental Evidence of Radiation Reaction in the Collision of a High-Intensity Laser Pulse with a Laser-Wakefield Accelerated Electron Beam

    Get PDF
    The dynamics of energetic particles in strong electromagnetic fields can be heavily influenced by the energy loss arising from the emission of radiation during acceleration, known as radiation reaction. When interacting with a high-energy electron beam, today's lasers are sufficiently intense to explore the transition between the classical and quantum radiation reaction regimes. We present evidence of radiation reaction in the collision of an ultrarelativistic electron beam generated by laser-wakefield acceleration (μ 500 MeV) with an intense laser pulse (a0>10). We measure an energy loss in the postcollision electron spectrum that is correlated with the detected signal of hard photons (γ rays), consistent with a quantum description of radiation reaction. The generated γ rays have the highest energies yet reported from an all-optical inverse Compton scattering scheme, with critical energy >30 MeV

    Generation of meter-scale hydrogen plasmas and efficient, pump-depletion-limited wakefield excitation using 10 GeV electron bunches

    Full text link
    High repetition rates and efficient energy transfer to the accelerating beam are important for a future linear collider based on the beam-driven plasma wakefield acceleration scheme (PWFA-LC). This paper reports the first results from the Plasma Wakefield Acceleration Collaboration (E300) that are beginning to address both of these issues using the recently commissioned FACET-II facility at SLAC. We have generated meter-scale hydrogen plasmas using time-structured 10 GeV electron bunches from FACET-II, which hold the promise of dramatically increasing the repetition rate of PWFA by rapidly replenishing the gas between each shot compared to the hitherto used lithium plasmas that operate at 1-10 Hz. Furthermore, we have excited wakes in such plasmas that are suitable for high gradient particle acceleration with high drive-bunch to wake energy transfer efficiency -- a first step in achieving a high overall energy transfer efficiency. We have done this by using time-structured electron drive bunches that typically have one or more ultra-high current (>30 kA) femtosecond spike(s) superimposed on a longer (~0.4 ps) lower current (<10 kA) bunch structure. The first spike effectively field-ionizes the gas and produces a meter-scale (30-160 cm) plasma, whereas the subsequent beam charge creates a wake. The length and amplitude of the wake depends on the longitudinal current profile of the bunch and plasma density. We find that the onset of pump depletion, when some of the drive beam electrons are nearly fully depleted of their energy, occurs for hydrogen pressure >1.5 Torr. We also show that some electrons in the rear of the bunch can gain several GeV energies from the wake. These results are reproduced by particle-in-cell simulations using the QPAD code. At a pressure of ~2 Torr, simulations results and experimental data show that the beam transfers about 60% of its energy to the wake

    Wakefield Generation in Hydrogen and Lithium Plasmas at FACET-II: Diagnostics and First Beam-Plasma Interaction Results

    Full text link
    Plasma Wakefield Acceleration (PWFA) provides ultrahigh acceleration gradients of 10s of GeV/m, providing a novel path towards efficient, compact, TeV-scale linear colliders and high brightness free electron lasers. Critical to the success of these applications is demonstrating simultaneously high gradient acceleration, high energy transfer efficiency, and preservation of emittance, charge, and energy spread. Experiments at the FACET-II National User Facility at SLAC National Accelerator Laboratory aim to achieve all of these milestones in a single stage plasma wakefield accelerator, providing a 10 GeV energy gain in a <1 m plasma with high energy transfer efficiency. Such a demonstration depends critically on diagnostics able to measure emittance with mm-mrad accuracy, energy spectra to determine both %-level energy spread and broadband energy gain and loss, incoming longitudinal phase space, and matching dynamics. This paper discusses the experimental setup at FACET-II, including the incoming beam parameters from the FACET-II linac, plasma sources, and diagnostics developed to meet this challenge. Initial progress on the generation of beam ionized wakes in meter-scale hydrogen gas is discussed, as well as commissioning of the plasma sources and diagnostics

    A spectrometer for ultrashort gamma-ray pulses with photon energies greater than 10 MeV

    Get PDF
    We present a design for a pixelated scintillator based gamma-ray spectrometer for non-linear inverse Compton scattering experiments. By colliding a laser wakefield accelerated electron beam with a tightly focused, intense laser pulse, gamma-ray photons up to 100 MeV energies and with few femtosecond duration may be produced. To measure the energy spectrum and angular distribution, a 33 × 47 array of cesium-iodide crystals was oriented such that the 47 crystal length axis was parallel to the gamma-ray beam and the 33 crystal length axis was oriented in the vertical direction. Using an iterative deconvolution method similar to the YOGI code, modeling of the scintillator response using GEANT4 and fitting to a quantum Monte Carlo calculated photon spectrum, we are able to extract the gamma ray spectra generated by the inverse Compton interaction

    Dependence of the number-weighted angular distribution of Compton-scattered photon beams on the laser intensity

    No full text
    Inverse Compton scattering of ultra-relativistic electron beams in the field of a high-intensity laser produces photon beams with angular and spectral distributions that are strongly dependent on the laser intensity. Here we show that the laser intensity at the interaction point can be accurately inferred from the measurement of the angular number-density distribution of Compton-scattered photon beams. The theoretical expressions, supported by numerical simulations, are accurate to within 10%–15% in a wide range of laser intensities (dimensionless intensity 5≤a0≤50) and electron energies (250MeV≤E≤15GeV), and accounts for experimental features such as the finite transverse size of the electron beam, low-energy cutoffs in the photon detector, and the possibility of a transverse misalignment between the electron beam and the laser focus
    corecore