14 research outputs found

    HARMONIZAÇÃO ESTÉTICA DO SORRISO COM FACETAS DIRETAS EM RESINA COMPOSTA

    Get PDF
    Composite resins are highly versatile materials that enable various applications in the field of aesthetic adhesive dentistry. Among its clinical indications the making of direct facets in the anterior superior teeth has been emphasizing, since it effectively corrects asymmetries and colorations. It is therefore a lower cost patient procedure compared to indirect facets, as well as aesthetic performance, predictability and longevity of clinical success. This work aimed to report the clinical case of a patient with aesthetic alteration in the anterior superior teeth: severe central incisor pigmentation and lateral rotation, and dental disproportionality. The technique of mock up diagnostic waxing was used to compose the planning of direct facets in the respective anterosuperior teeth mentioned in composite resin. The use of the direct facets in composite resin demonstrated the quality of this material and its high versatility, which allows the dental surgeon to use it in several procedures. It was possible to correct the color, shape, alignment and function of the restored teeth, resulting in an improvement in the patient's self-esteem and quality of life.As resinas compostas são materiais altamente versáteis que possibilitam diversas aplicações no campo da odontologia adesiva estética. Dentre suas indicações clínicas a confecção de facetas diretas nos dentes anterossuperiores vem se destacando, visto que corrige de forma eficaz assimetrias e colorações. Trata-se, portanto, de um procedimento de menor custo ao paciente em comparação às facetas indiretas, bem como alta performance estética, previsibilidade e longevidade de sucesso clínico. Este trabalho objetivou relatar o caso clínico de uma paciente com alteração estética nos dentes anterossuperiores: severa pigmentação dos incisivos centrais e giroversão dos laterais, além de desproporcionalidade dentária. Utilizou-se a técnica de enceramento diagnóstico com mock up para compor o planejamento de facetas diretas nos respectivos dentes anterossuperiores citados em resina composta. O emprego das facetas diretas em resina composta demonstrou a qualidade que este material possui e a sua alta versatilidade, o que permite ao cirurgião-dentista utilizá-lo em diversos procedimentos. Foi possível a adequada correção de cor, forma, alinhamento e função dos dentes restaurados, resultando em uma melhora da autoestima e qualidade de vida da paciente

    Influence of pulse-delay curing on sorption and solubility of a composite resin

    Get PDF
    The purpose of this study was to evaluate the sorption and solubility of a composite resin (TPH³; Dentsply) cured with halogen light due to different storage media and curing modes. The methodology was based on the ISO 4049 standard. Two independent groups were established according to the storage time (7 days-G1; 60 days-G2). A stainless steel mould (2 mm x 8 mm Ø) was used. The selected curing modes were: I (Conventional - C): 40s - 600 mW/cm²; II (Pulse I - PD): 3 s - 200 mW/cm² + 2 min (delay) + 39 s - 600 mW/cm²; III (Pulse II): 10 s - 200 mW/cm² + 2 min (delay) + 37 s - 600 mW/cm²; IV (Pulse III): 3 s- 600 mW/cm² + 2 min (delay) + 37 s -600 mW/cm². The media used were: distilled water, 75% ethanol and 100% chlorophorm. Five repetitions were made for each group. The specimens were placed in a desiccator at 37ºC for 24 h and, after that, at 23ºC for 1 h to be weighed until a constant mass (m1) was obtained. The discs were immersed separately into the 3 media for 7 days (G1) and 60 days (G2), and thereafter reweighed (m2). The reconditioning in the desiccator was done until a constant mass (m3) was obtained. Sorption and solubility were calculated and the data of G1 and the sorption data of G2 were subjected to two-way ANOVA and Tukey's tests (p=0.05). The solubility data of G2 were analyzed by Kruskal-Wallis test (p=0.05). For G1 and G2, no statistically significant differences were found in sorption among curing techniques (p>;0.05). The solubility values were negative, which means that there was mass gain. Regarding the storage media, in G2 chlorophorm had the highest sorption values. It may be concluded that the curing modes (C and PD I, II and III) did not affect the sorption of the tested composite resin. However, different storage media influenced sorption behavior. The solubility test demonstrated negative data, masking the real solubility

    Influence of pulse-delay curing on sorption and solubility of a composite resin

    Get PDF
    The purpose of this study was to evaluate the sorption and solubility of a composite resin (TPH³; Dentsply) cured with halogen light due to different storage media and curing modes. The methodology was based on the ISO 4049 standard. Two independent groups were established according to the storage time (7 days-G1; 60 days-G2). A stainless steel mould (2 mm x 8 mm Ø) was used. The selected curing modes were: I (Conventional - C): 40s - 600 mW/cm²; II (Pulse I - PD): 3 s - 200 mW/cm² + 2 min (delay) + 39 s - 600 mW/cm²; III (Pulse II): 10 s - 200 mW/cm² + 2 min (delay) + 37 s - 600 mW/cm²; IV (Pulse III): 3 s- 600 mW/cm² + 2 min (delay) + 37 s -600 mW/cm². The media used were: distilled water, 75% ethanol and 100% chlorophorm. Five repetitions were made for each group. The specimens were placed in a desiccator at 37ºC for 24 h and, after that, at 23ºC for 1 h to be weighed until a constant mass (m1) was obtained. The discs were immersed separately into the 3 media for 7 days (G1) and 60 days (G2), and thereafter reweighed (m2). The reconditioning in the desiccator was done until a constant mass (m3) was obtained. Sorption and solubility were calculated and the data of G1 and the sorption data of G2 were subjected to two-way ANOVA and Tukey's tests (p=0.05). The solubility data of G2 were analyzed by Kruskal-Wallis test (p=0.05). For G1 and G2, no statistically significant differences were found in sorption among curing techniques (p>0.05). The solubility values were negative, which means that there was mass gain. Regarding the storage media, in G2 chlorophorm had the highest sorption values. It may be concluded that the curing modes (C and PD I, II and III) did not affect the sorption of the tested composite resin. However, different storage media influenced sorption behavior. The solubility test demonstrated negative data, masking the real solubility

    Tratamento de Hiperplasia Fibrosa Inflamatória pelo Método de Compressão Gradual – Caso Clínico

    Get PDF
    ResumoA hiperplasia fibrosa inflamatória é um tipo de alteração tecidual que pode ser causada pela câmara de sucção presente em algumas próteses totais, especialmente, as superiores. Existem vários processos para a eliminação desse tecido hiperplásico, que vão desde os métodos conservadores até aos procedimentos cirúrgicos. O presente trabalho tem por objetivo relatar um método não traumático de se remover a hiperplasia, no qual se empregou uma terapêutica de eliminação total da lesão e suspensão dos agentes irritantes com o preenchimento gradativo da câmara de sucção, demonstrando, ao final, que se pode obter um resultado clínico satisfatório.Palavras-chave: Prótese Total; Reabilitação Bucal; Hiperplasia Gengival.   AbstractThe inflammatory fibrous hyperplasia is a type of tissue alteration that can be caused by the suction chamber present in some complete prostheses, especially, the upper prosthesis dentures. There are several processes for the removal of hyperplasic tissue, they are going from the conservative methods to the surgical procedures. This present study aims to reporting a no traumatic method of removing hyperplasia, in which was used a therapeutics of full elimination of the lesion and the irritating agents’ suspension with the gradual completion of the suction chamber showing, at the end, that one can obtain a satisfactory clinical result.Keywords: Denture; Complete; Mouth Rehabilitation; Gingival Hyperplasia

    Avaliação das fontes de luz em uso nas clínicas odontológicas da FO/UFG: acompanhamento de 1 ano

    Get PDF
    Objetivo: Avaliar o estado de conservação e a densidade de potência das fontes de luz disponíveis para o atendimento clínico na Faculdade de Odontologia da Universidade Federal de Goiás (FO/UFG), em 2011-2012. Métodos: As seguintes informações e especificações técnicas das referidas fontes de luz foram coletadas: ambulatório (clínica odontológica) onde está alocada, tipo de fonte [aparelho de luz halógena e Diodo Emissores de Luz (LEDs)], marca, teste de paralelismo (exclusivamente para as fontes de luz halógena), estado de conservação da ponteira transmissora de luz, densidade de potência em mW/cm2 e data da aquisição. Os dados obtidos foram submetidos à análise estatística descritiva, teste t de Student, ANOVA a um critério e teste de Tukey para comparações múltiplas (P<0,05). Resultados: No período de 2011-2012, a FO/UFG dispunha respectivamente de 20 e 22 fontes de luz para atendimento clínico. Quanto ao seu estado de conservação observou-se que em 2011, 90% das fontes de luz encontravam-se em inadequado estado de conservação, enquanto em 2012 este número foi de 54%. Em termos de densidade de potência 55% das fontes de luz apresentavam densidade menor que 300 mW/cm2 em 2011, enquanto em 2012 este resultado foi de 54,54%. Não foi observada diferença estatística significante quanto à densidade de potência das fontes de luz halógena (P=0,81) e LED (P=0,41) testadas no período avaliado. Conclusões: As fontes de luz no período de acompanhamento de um ano apresentaram uma melhoria no seu estado de conservação, enquanto a densidade de potência permaneceu similar

    Fuentes de luz de uso clínico en el pre grado: 7 años de seguimento

    Get PDF
    Objetive: To monitor the light curing units available at undergraduate dental clinics of a Brazilian Public Higher Education Institution for seven uninterrupted years. Materials and methods: In the period between 2011-2017, the quality control of light curing units at the Faculty of Dentistry, Federal University of Goiás, was evaluated by analyzing their state of conservation and power density (mW/cm2). Data obtained were subjected to descriptive statistical analysis and Levene, Shapiro-Wilk, Kruskal-Wallis, Dunn and Chi-square tests (P <0.05). Results: Regarding the conservation status of the light curing units, comparatively, there was no statistically significant difference between the years 2012, 2016 and 2017 (p> 0.05). Statistically significant differences were found for power density values between years (p <0.0001). In pairwise comparisons, the power density values for the years 2011 (p <0.01) and 2012 (p <0.05) were statistically different from the years 2015, 2016 and 2017. Conclusions: A significant improvement in the state of conservation of light curing units was observed in the initial four years of evaluations, with a decline in the fifth year and stabilization in the last two years. Regarding the power density of the light curing units, a gradual increase was observed in the seven years of study, with stabilization of the results after the fifth year of quality control.Objetivo: Realizar, durante siete años ininterrumpidos, un control y seguimiento de las fuentes de luz disponibles en las clínicas odontológicas de pre graado de una Institución de Enseñanza Superior Pública Brasileña. Material y métodos: Durante el período comprendido entre 2011-2017 se evaluó el control de calidad de las fuentes de luz de la Facultad de Odontología de la Universidad Federal de Goiás a través del análisis de su estado de conservación y de su densidad de potencia (mW/cm2). Los datos obtenidos se sometieron a un análisis estadístico descritpivo y a las pruebas de Levene, Shapiro-Wilk, Kruskal-Wallis, Dunn y Chi-cuadrado (P<0,05). Resultados: No se observaron diferencias estadísticas significativas del estado de conservación de las fuentes de luz entre los años 2012, 2016 y 2017 (p>0,05). Sí se observaron diferencias estadísticas significativas entre los valores de densidad de potência entre dichos años (p<0,0001). En las comparaciones por pares, los valores de densidad de potencia para los años 2011 (p<0,01) y 2012 (p<0,05) fueron estadísticamente diferentes de los años 2015, 2016 y 2017. Conclusiones: Comparativamente se observó una mejora sustancial del estado de conservación de las fuentes de luz en los cuatro años iniciales de evaluaciones, con una disminución en el quinto año y una estabilización en los dos últimos años. Durante los siete años de estudio de la densidad de potencia de las fuentes de luz se observó en un aumento gradual de la misma con una estabilización de los resultados a partir del quinto año de control de calidad

    Resistencia a tração de agentes cimentantes usados na fixação de ligas de paladio-prata e niquel-cromo a dentina

    No full text
    Orientador: Lourenço Correr SobrinhoTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de PiracicabaResumo: o propósito deste estudo foi avaliar a resistência à tração da união de dois tipos de ligas metálicas (Litecast B e Pors-on 4) fixadas em dentina humana tratada sob três condições (condicionada por 1O segundos com ácido fosfórico 35%, ácido poliacrílico 25% e não condicionada). Os cimentos foram 1- de fosfato de zinco, 2- ionômero d vidro e, 3- cimento resinoso. Noventa molares humanos foram inseridos em resina acrílica e desgastados com lixas d'água de granulação nOs 120, 320 e 600 até aproximadamente 2 mm além da junção amelo-dentinária. Noventa corpos-de-prova com 6,0 mm de diâmetro por 7 mm de altura foram confeccionados, sendo quarenta e cinco com liga de níquel-cromo (Litecast B) e quarenta e cinco com liga paládio-prata (Pors-on 4). Quinze corpos-de-prova de cada liga foram fixadas com os cimentos de fosfato de zinco (55 White), ionômero de vidro (Vitremer - 3M) e cimento resinoso (3M). Antes da fixação, a dentina de cinco corpos-de-prova foi condicionada com ácido fosfórico 35%, cinco com ácido poliacrílico 25%, ambas por 1O segundos e cinco não condicionadas. Todos os corpos-de-prova foram armazenados a 37°C por 24 horas antes do ensaio. Em seguida, os corpos-de-prova foram submetidos ao ensaio de tração em uma máquina Instron a velocidade de 0,5 mm/min. até a separação entre liga metálica e dente. Os resultados foram submetidos a análise de variância e ao teste de Tukey (p<0,05). Os dados indicaram que: Para a liga Pors-on 4 o cimento de resina apresentou valores de resistência à remoção, por tração, estatisticamente superiores ao cimento de ionômero de vidro e de fosfato de zinco para as três condições de tratamento da dentina. O cimento de ionômero de vidro apresentou valores estatisticamente superior ao de fosfato de zinco, para a dentina condicionada com ácido fosfório 35% e ácido poliacrílico 25%. Nenhuma diferença estatística foi encontrada entre o cimento de ionômero de vidro e fosfato de zinco para a superfície não condicionada; Para a liga Litecast B, o cimento de resina apresentou valores de remoção, por tração, estatisticamente superiores aos cimentos de fosfato de zinco e de ionômero de vidro para a dentina condicionada com ácido fosfórico 35% e poliacrílico 25%. O cimento de fosfato de zinco foi superior ao de resina para a dentina não condicionada. Nenhuma diferença foi observada entre o cimento de fosfato de zinco e de ionômero de vidro para as três condições da dentina e entre o cimento de ionômero de vidro e de resina para a dentina não condicionada. Para as duas ligas, o cimento de resina mostrou valores de remoção, por tração, superiores aos do fosfato de zinco e ionômero de vidro. De uma maneira geral, a liga liga Pors-on 4 apresentou valores de resistência a remoção por tração estatisticamente superiores a liga Litecast B, para todos os cimentos e tratamentos da dentinaAbstract: The aim of this study was to evaluate the tensile bond strength of two alloy systems (Litecast B and Pors-on 4) luted with three cements to dentin in three conditions (etched with 35% phosphoric acid, 25% polyacrylic acid for 10 seconds and no etching). Ninety extracted human molars were embedded in resin with 10 mm in diameter of exposed dentin which had been grounded with 120, 320 and 600 grit SiC paper. Forty-tive specimens with 6.0 mm in diameter and 7.0 mm long, were fabricated with nickel chromium-beryllium (Litecast B) and palladium-silver (Pors-on 4) alloys. Fifteen specimens of each alloy systems were luted with zinc phosphate cement (SS White), glass ionomer cement (3M) and resin cement (3M). Prior to cementation, the dentin of five specimens were etched with 35% phosphoric acid, tive with 25% polyacrylic acid for 10 seconds and tive no etching. Ali samples were stored in distilled water at 37° C for 24 hours prior to testing. After the specimens were submitted to the tensile bond strength in an Instron at a crosshead speed of 0.5 mm/min until failure. The results were submitted to variance analysis and Tukey's test (p<0.05). The data indicated that for Pors-on 4: the resin cement showed tension bond strength values stronger than glass ionomer cement and zinc phosphate cement in three dentin conditions (p<0. 05). Glass ionomer cement showed values stronger than zinc phosphate for dentin etched with phosphoric acid and polyacrilic acid. For no etching no difference was found between glass ionomer cement and zinc phosphate cement; for Litecast B: the resin cement was signiticantly stronger than zinc phosphate and glass ionomer cement for dentin etched with two acid. Zinc phosphate was stronger than resin cement for dentin no etching. No difference was found between zinc phosphate and glass ionômero cement in three dentin conditions and between glass ionomer cement and resin cement to the dentin no etching. For the two alloy systems the resin cement showed tensile bond strength better than glass ionomer and zinc phosphate cement for three dentin conditions. In general, Pors-on 4 alloy showed tension strength values stronger than Litecast B alloy, in three dentin conditions and cementsDoutoradoDoutor em Materiais Dentário

    Removable Partial Prosthesis Whit Macro-Rests For Restauration Of The Vertical Dimension In The Patients With Wornteeth - A Clinic Report

    No full text
    AbstractRemovable partial dentures are an option as a form of treatment that can be given in cases where there is tooth wear come from parafunctional habits coupled with loss of teeth, especially the later ones, it can be characterized as pathological and often is related to the age of patients needing restorative treatment. In these cases a simple, economical and reduced time way is the use of removable partial denture with macro-rest, to be considered a conservative treatment with aspects of reversibility and well affordable. This study aims to report a case which consisted of functional oral rehabilitation and aesthetic, using a removable partial denture with macro-rest to restore the functions of the stomatognathic system.Keywords: Oral rehabilitation; Removable partial denture prosthesis; Vertical dimension;  ResumoAs próteses parciais removíveis constituem uma opção como modalidade de tratamento que podem ser indicadas nos casos em que há desgaste dentário oriundo de hábitos parafuncionais aliados a perda de dentes, especialmente os posteriores, pode ser caracterizado como patológico e que muitas vezes está relacionado à idade do paciente necessitando de tratamento restaurador. Nestes casos uma maneira simples, econômica e em tempo reduzido é a utilização de prótese parcial removível com macro-apoios, por ser considerado um tratamento conservador com aspectos de reversibilidade e custo bem acessível. O presente trabalho tem por objetivo relatar um caso clínico que consistiu na reabilitação bucal funcional e estética, empregando uma prótese parcial removível com macro-apoios para restabelecer as funções do sistema estomatognático.Palavras-chave: Reabilitação bucal; Prótese parcial removível; Dimensão vertica