23 research outputs found

    Physicochemical and biological properties of novel chlorhexidine‐loaded nanotube‐modified dentin adhesive

    Get PDF
    A commercially available three‐step (etch‐and‐rinse) adhesive was modified by adding chlorhexidine (CHX)‐loaded nanotubes (HalloysiteÂź, HNT) at two concentrations (CHX10% and CHX20%). The experimental groups were: SBMP (unmodified adhesive, control), HNT (SBMP modified with HNT), CHX10 (SBMP modified with HNT loaded with CHX10%), and CHX20 (SBMP modified with HNT loaded with CHX20%). Changes in the degree of conversion (DC%), Knoop hardness (KHN), water sorption (WS), solubility (SL), antimicrobial activity, cytotoxicity, and anti‐matrix metalloproteinase [MMP‐1] activity (collagenase‐I) were evaluated. In regards to DC%, two‐way ANOVA followed by Tukey’s post‐hoc test revealed that only the factor “adhesive” was statistically significant (p 0.05). For Knoop microhardness, one‐way ANOVA followed by the Tukey’s test showed statistically significant differences when comparing HNT (20.82 ± 1.65) and CHX20% (21.71 ± 2.83) with the SBMP and CHX10% groups. All adhesives presented similar WS and cytocompatibility. The CHX‐loaded nanotube‐modified adhesive released enough CHX to inhibit the growth of S. mutans and L. casei. Adhesive eluates were not able to effectively inhibit MMP‐1 activity. The evaluation of higher CHX concentrations might be necessary to provide an effective and predictable MMP inhibition. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res B Part B, 2018. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 868–875, 2019.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/148225/1/jbmb34183_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/148225/2/jbmb34183.pd

    Doxycycline-loaded nanotube-modified adhesives inhibit MMP in a dose-dependent fashion

    Get PDF
    OBJECTIVES: This article evaluated the drug loading, release kinetics, and matrix metalloproteinase (MMP) inhibition of doxycycline (DOX) released from DOX-loaded nanotube-modified adhesives. DOX was chosen as the model drug, since it is the only MMP inhibitor approved by the U.S. Food and Drug Administration. MATERIALS AND METHODS: Drug loading into the nanotubes was accomplished using DOX solution at distinct concentrations. Increased concentrations of DOX significantly improved the amount of loaded DOX. The modified adhesives were fabricated by incorporating DOX-loaded nanotubes into the adhesive resin of a commercial product. The degree of conversion (DC), Knoop microhardness, DOX release kinetics, antimicrobial, cytocompatibility, and anti-MMP activity of the modified adhesives were investigated. RESULTS: Incorporation of DOX-loaded nanotubes did not compromise DC, Knoop microhardness, or cell compatibility. Higher concentrations of DOX led to an increase in DOX release in a concentration-dependent manner from the modified adhesives. DOX released from the modified adhesives did not inhibit the growth of caries-related bacteria, but more importantly, it did inhibit MMP-1 activity. CONCLUSIONS: The loading of DOX into the nanotube-modified adhesives did not compromise the physicochemical properties of the adhesives and the released levels of DOX were able to inhibit MMP activity without cytotoxicity. CLINICAL SIGNIFICANCE: Doxycycline released from the nanotube-modified adhesives inhibited MMP activity in a concentration-dependent fashion. Therefore, the proposed nanotube-modified adhesive may hold clinical potential as a strategy to preserve resin/dentin bond stability

    Influence of Pre-Heating Regular Resin Composites and Flowable Composites on Luting Ceramic Veneers with Different Thicknesses

    Get PDF
    The aim of this study was to evaluate of pre-heating, filler contents and ceramic thickness on film thickness, microshear bond strength, degree of conversion and color change on ceramic veneers. Two experimental composites were prepared (Bis-GMA/UDMA/BisEMA/ TEGDMA), with different amounts of filler (65% or 50%wt) simulating a conventional and a flowable composite. The flowable (F) was used at room temperature and, the conventional either at room temperature (C) or pre-heated (CPH). Disk-shaped ceramics with different thickness (0.4 mm, 0.8 mm, 1.5 mm) were prepared. The film thickness was evaluated according to the ISO 4049 (n=10). The microshear bond strength (n=10) was evaluated in enamel using tubing specimens light-cured through the ceramic veneer. The degree of conversion was evaluated using Raman spectroscopy. The color change of the ceramic restorations (n=10) was evaluated by spectrophotometry. The results were submitted to 2-way ANOVA and Tukeyñ€ℱs post hoc test (a=5%). For the film thickness 1-way ANOVA was used (a=5%). The C presented the thicker film thickness; the CPH produced a similar film thickness in comparison to the F. All composites showed similar microshear bond strength. The degree of conversion of the F was higher than the C and CPH. The degree of conversion of the composites photo-activated through a 0.4 mm was higher than the composites photo-activated through thicker ceramics. The C showed the highest color change, while the CPH showed similar color change to the F. In conclusion, pre-heated conventional composites seem to be a potential alternative to lute ceramic veneers such as the flowable composites

    Chlorhexidine-modified nanotubes and their effects on the polymerization and bonding performance of a dental adhesive

    Get PDF
    Objectives: The purpose of this study was to synthesize chlorhexidine (CHX)-encapsulated aluminosilicate clay nanotubes (HalloysiteŸ, HNTs) and to incorporate them into the primer/adhesive components of an etch-and-rinse adhesive system (SBMP; Scotchbond Multipurpose, 3M ESPE) and to test their effects on degree of conversion, viscosity, immediate and long-term bonding to dentin. Methods: CHX-modified HNTs were synthesized using 10% or 20% CHX solutions. The primer and the adhesive components of SBMP were incorporated with 15wt.% of the CHX-encapsulated HNTs. Degree of conversion (DC) and viscosity analyses were performed to characterize the modified primers/adhesives. For bond strength testing, acid-etched dentin was treated with one of the following: SBMP (control); 0.2%CHX solution before SBMP; CHX-modified primers+SBMP adhesive; SBMP primer+CHX-modified adhesives; and SBMP primer+CHX-free HNT-modified adhesive. The microtensile bond strength test was performed after immediate (24h) and long-term (6 months) of water storage. Data were analyzed using ANOVA and Tukey (α=5%) and the Weibull analysis. Results: DC was greater for the CHX-free HNT-modified adhesive, whereas the other experimental adhesives showed similar DC as compared with the control. Primers were less viscous than the adhesives, without significant differences within the respective materials. At 24h, all groups showed similar bonding performance and structural reliability; whereas at the 6-month period, groups treated with the 0.2%CHX solution prior bonding or with the CHX-modified primers resulted in greater bond strength than the control and superior reliability. Significance: The modification of a primer or adhesive with CHX-encapsulated HNTs was an advantageous approach that did not impair the polymerization, viscosity and bonding performance of the materials, showing a promising long-term effect on resin-dentin bonds

    Incorporation of Arginine to Commercial Orthodontic Light-Cured Resin Cementsñ€”Physical, Adhesive, and Antibacterial Properties

    Get PDF
    (1) Background: The amino acid arginine is now receiving great attention due to its potential anti-caries benefits. The purpose of this in vitro study was to evaluate the shear bond strength (SBS), ultimate tensile strength (UTS), and antimicrobial potential (CFU) of two arginine-containing orthodontic resin cements. (2) Methods: Forty bovine incisors were separated into four groups (n = 10): Orthocem, Orthocem + arginine (2.5 wt%), Transbond XT, and Transbond XT + arginine (2.5 wt%). The brackets were fixed to the flat surface of the enamel, and after 24 h the SBS was evaluated using the universal testing machine (Instron). For the UTS test, hourglass samples (n = 10) were made and tested in a mini-testing machine (OM-100, Odeme). For the antibacterial test (colony forming unit-CFU), six cement discs from each group were made and exposed to Streptococcus mutans UA159 biofilm for 7 days. The microbiological experiment was performed by serial and triplicate dilutions. The data from each test were statistically analyzed using a two-way ANOVA, followed by Tukey’s test (α = 0.05). (3) Results: The enamel SBS mean values of Transbond XT were statistically higher than those of Orthocem, both with and without arginine (p = 0.02033). There was no significant difference in the SBS mean values between the orthodontic resin cements, either with or without arginine (p = 0.29869). The UTS of the Transbond XT was statistically higher than the Orthocem, but the addition of arginine at 2.5 wt% did not influence the UTS for either resin cement. The Orthocem + arginine orthodontic resin cement was able to significantly reduce S. mutans growth, but no difference was observed for the Transbond XT (p = 0.03439). (4) Conclusion: The incorporation of arginine to commercial orthodontic resin cements may be an efficient preventive strategy to reduce bacterial growth without compromising their adhesive and mechanical properties

    Relation between handling characteristics and application time of four photo-polymerized resin composites

    Full text link
    OBJECTIVE: To investigate the relation between handling characteristics and application time of four composite materials with subjectively different viscosities. METHODS: Eight experienced faculty members placed one Class II and one Class IV restoration in a random sequence into pre-prepared plastic teeth mounted on a typodont model, each using 4 types of composites (Herculite PrĂ©cis (M1), Kerr; Tertic N-Ceram (M2), Ivoclar Vivadent; Filtek Z350 (M3), 3M-ESPE; Charisma Opal (M4), HareausKulzer), resulting in a total of 64 restorations. The application process was filmed with a high definition video camera. Two evaluators watched the recordings in a random sequence as well, timed the composite application and wrote down their observations, which were dichotimised into positive and negative ones. Application times were analysed with a two-way Kruskal Wallis test (time x dentist) and the observation data were analysed with a chi-square test (P < 0.05). RESULTS: Materials did not differ in their application time (P > 0.05). The mean application time was 12 ÂŒ minutes for the Class II and 9 Ÿ minutes for Class IV restorations. However, there were statistically significant differences between the dentists in terms of application time. The observation data showed no significant difference between Class II and Class IV restorations but there were significant material differences (P < 0.05). M2 yielded 6% negative observations, while the other materials were between 35% and 38%. CONCLUSION: There was no association between the handling characteristics of the tested composite resins and the speed of application. However, one of the tested materials (M2) showed significantly less problems in the application process
    corecore