4 research outputs found

    Clinical and phantom validation of a deep learning based denoising algorithm for F-18-FDG PET images from lower detection counting in comparison with the standard acquisition

    No full text
    International audienceAbstract Background PET/CT image quality is directly influenced by the F-18-FDG injected activity. The higher the injected activity, the less noise in the reconstructed images but the more radioactive staff exposition. A new FDA cleared software has been introduced to obtain clinical PET images, acquired at 25% of the count statistics considering US practices. Our aim is to determine the limits of a deep learning based denoising algorithm (SubtlePET) applied to statistically reduced PET raw data from 3 different last generation PET scanners in comparison to the regular acquisition in phantom and patients, considering the European guidelines for radiotracer injection activities. Images of low and high contrasted (SBR = 2 and 5) spheres of the IEC phantom and high contrast (SBR = 5) of micro-spheres of Jaszczak phantom were acquired on 3 different PET devices. 110 patients with different pathologies were included. The data was acquired in list-mode and retrospectively reconstructed with the regular acquisition count statistic (PET100), 50% reduction in counts (PET50) and 66% reduction in counts (PET33). These count reduced images were post-processed with SubtlePET to obtain PET50 + SP and PET33 + SP images. Patient image quality was scored by 2 senior nuclear physicians. Peak-signal-to-Noise and Structural similarity metrics were computed to compare the low count images to regular acquisition (PET100). Results SubtlePET reliably denoised the images and maintained the SUV max values in PET50 + SP. SubtlePET enhanced images (PET33 + SP) had slightly increased noise compared to PET100 and could lead to a potential loss of information in terms of lesion detectability. Regarding the patient datasets, the PET100 and PET50 + SP were qualitatively comparable. The SubtlePET algorithm was able to correctly recover the SUV max values of the lesions and maintain a noise level equivalent to full-time images. Conclusion Based on our results, SubtlePET is adapted in clinical practice for half-time or half-dose acquisitions based on European recommended injected dose of 3 MBq/kg without diagnostic confidence loss

    Total Metabolic Tumor Volume on 18F-FDG PET/CT Is a Useful Prognostic Biomarker for Patients with Extensive Small-Cell Lung Cancer Undergoing First-Line Chemo-Immunotherapy

    No full text
    Background: We aimed to evaluate the prognostic value of imaging biomarkers on 18F-FDG PET/CT in extensive-stage small-cell lung cancer (ES-SCLC) patients undergoing first-line chemo-immunotherapy. Methods: In this multicenter and retrospective study, we considered two cohorts, depending on the type of first-line therapy: chemo-immunotherapy (CIT) versus chemotherapy alone (CT). All patients underwent baseline 18-FDG PET/CT before therapy between June 2016 and September 2021. We evaluated clinical, biological, and PET parameters, and used cutoffs from previously published studies or predictiveness curves to assess the association with progression-free survival (PFS) or overall survival (OS) with Cox prediction models. Results: Sixty-eight patients were included (CIT: CT) (36: 32 patients). The median PFS was 5.9:6.5 months, while the median OS was 12.1:9.8 months. dNLR (the derived neutrophils/(leucocytes-neutrophils) ratio) was an independent predictor of short PFS and OS in the two cohorts (p high if > 241 cm3) correlated with outcomes, but only in the CIT cohort (PFS for TMTVhigh in multivariable analysis: HR 2.5; 95%CI 1.1–5.9). Conclusion: Baseline 18F-FDG PET/CT using TMTV could help to predict worse outcomes for ES-SCLC patients undergoing first-line CIT. This suggests that baseline TMTV may be used to identify patients that are unlikely to benefit from CIT
    corecore