71 research outputs found

    COVID-19 Outcomes in Kidney Transplant Recipients in a German Transplant Center

    Get PDF
    Kidney transplant recipients (KTRs) show higher morbidity and mortality from COVID-19 than the general population and have an impaired response to vaccination. We analyzed COVID-19 incidence and clinical outcomes in a single-center cohort of approximately 2500 KTRs. Between 1 February 2020 and 1 July 2022, 578 KTRs were infected with SARS-CoV-2, with 25 (4%) recurrent infections. In total, 208 KTRs (36%) were hospitalized, and 39 (7%) died. Among vaccinated patients, infection with the Omicron variant had a mortality of 2%. Unvaccinated patients infected with the Omicron variant showed mortality (9% vs. 11%) and morbidity (hospitalization 52% vs. 54%, ICU admission 12% vs. 18%) comparable to the pre-Omicron era. Multivariable analysis revealed that being unvaccinated (OR = 2.15, 95% CI [1.38, 3.35]), infection in the pre-Omicron era (OR = 3.06, 95% CI [1.92, 4.87]), and higher patient age (OR = 1.04, 95% CI [1.03, 1.06]) are independent risk factors for COVID-19 hospitalization, whereas a steroid-free immunosuppressive regimen was found to reduce the risk of COVID-19 hospitalization (OR = 0.51, 95% CI [0.33, 0.79]). This suggests that both virological changes in the Omicron variant and vaccination reduce the risk for morbidity and mortality from COVID-19 in KTRs. Our data extend the knowledge from the general population to KTRs and provide important insights into outcomes during the Omicron era

    Self-reported risk of obstructive sleep apnea syndrome, and awareness about it in the community of 4 insular complexes comprising 41 Greek Islands

    Get PDF
    Obstructive Sleep Apnea Syndrome (OSAS) is a chronic disease that significantly increases morbidity and mortality of the affected population. There is lack of data concerning the OSAS prevalence in the insular part of Greece. The purpose of this study was to investigate the self-reported prevalence of OSAS in 4 Greek insular complexes comprising 41 islands, and to assess the awareness of the population regarding OSAS and its diagnosis. Our study comprised 700 participants from 41 islands of the Ionian, Cyclades, Dodecanese and Northeast Aegean island complexes that were studied by means of questionnaires via a telephone randomized survey (responsiveness rate of 25.74%). Participants were assessed by the Berlin Questionnaire (BQ) for evaluation of OSA risk, by the Epworth Sleepiness Scale (ESS) for evaluation of excessive daytime sleepiness, and by 3 questions regarding the knowledge and diagnosis of OSAS. The percentage of participants at high risk according to BQ was 27.29% and the percentage of people who were at high risk according to ESS was 15.43%. A percentage of 6.29% of the population was at high risk for OSAS (high risk both in BQ and ESS). A high percentage of 73.43%, were aware of OSAS as a syndrome however a significantly less percentage (28.00%) was aware of how a diagnosis of OSAS is established. The community prevalence of OSAS in Greek islands in combination with the low-level awareness of the OSAS diagnostic methods highlights the need for development of health promotion programs aiming at increasing the detection of patients at risk while increasing the awareness of OSAS

    Inter-annual trends of ultrafine particles in urban Europe

    Get PDF
    Ultrafine particles (UFP, those with diameters ≤ 100 nm), have been reported to potentially penetrate deeply into the respiratory system, translocate through the alveoli, and affect various organs, potentially correlating with increased mortality. The aim of this study is to assess long-term trends (5–11 years) in mostly urban UFP concentrations based on measurements of particle number size distributions (PNSD). Additionally, concentrations of other pollutants and meteorological variables were evaluated to support the interpretations. PNSD datasets from 12 urban background (UB), 5 traffic (TR), 3 suburban background (SUB) and 1 regional background (RB) sites in 15 European cities and 1 in the USA were evaluated. The non-parametric Theil-Sen's method was used to detect monotonic trends. Meta-analyses were carried out to assess the overall trends and those for different environments. The results showed significant decreases in NO, NO2, BC, CO, and particle concentrations in the Aitken (25–100 nm) and the Accumulation (100–800 nm) modes, suggesting a positive impact of the implementation of EURO 5/V and 6/VI vehicle standards on European air quality. The growing use of Diesel Particle Filters (DPFs) might also have clearly reduced exhaust emissions of BC, PM, and the Aitken and Accumulation mode particles. However, as reported by prior studies, there remains an issue of poor control of Nucleation mode particles (smaller than 25 nm), which are not fully reduced with current DPFs, without emission controls for semi-volatile organic compounds, and might have different origins than road traffic. Thus, contrasting trends for Nucleation mode particles were obtained across the cities studied. This mode also affected the UFP and total PNC trends because of the high proportion of Nucleation mode particles in both concentration ranges. It was also found that the urban temperature increasing trends might have also influenced those of PNC, Nucleation and Aitken modes.</p

    Results of the first European Source Apportionment intercomparison for Receptor and Chemical Transport Models

    Get PDF
    In this study, the performance of the source apportionment model applications were evaluated by comparing the model results provided by 44 participants adopting a methodology based on performance indicators: z-scores and RMSEu, with pre-established acceptability criteria. Involving models based on completely different and independent input data, such as receptor models (RMs) and chemical transport models (CTMs), provided a unique opportunity to cross-validate them. In addition, comparing the modelled source chemical profiles, with those measured directly at the source contributed to corroborate the chemical profile of the tested model results. The most used RM was EPA- PMF5. RMs showed very good performance for the overall dataset (91% of z-scores accepted) and more difficulties are observed with SCE time series (72% of RMSEu accepted). Industry resulted the most problematic source for RMs due to the high variability among participants. Also the results obtained with CTMs were quite comparable to their ensemble reference using all models for the overall average (>92% of successful z-scores) while the comparability of the time series is more problematic (between 58% and 77% of the candidates’ RMSEu are accepted). In the CTM models a gap was observed between the sum of source contributions and the gravimetric PM10 mass likely due to PM underestimation in the base case. Interestingly, when only the tagged species CTM results were used in the reference, the differences between the two CTM approaches (brute force and tagged species) were evident. In this case the percentage of candidates passing the z-score and RMSEu tests were only 50% and 86%, respectively. CTMs showed good comparability with RMs for the overall dataset (83% of the z-scores accepted), more differences were observed when dealing with the time series of the single source categories. In this case the share of successful RMSEu was in the range 25% - 34%.JRC.C.5-Air and Climat

    The Impact of Insulation and HVAC Degradation on Overall Building Energy Performance: A Case Study

    No full text
    Through monitoring of buildings, it can be proven that the performance of envelope elements and energy supply systems deteriorates with time. The results of this degradation are higher energy consumption and life cycle costs than projected in the building design phase. This paper considers the impacts of this deterioration on the whole building energy performance with the goal of improving the accuracy of long term performance calculations. To achieve that, simplified degradation equations found in literature are applied on selected envelope elements and heating system components of a single-family house in Germany. The energy performance of the building over 20 years is determined through simulations by EnergyPlus and MATLAB. The simulation results show that, depending on maintenance and primary heating system, the building can consume between 18.4% and 47.1% more primary energy over 20 years compared to a scenario in which no degradation were to occur. Thus, it can be concluded that considering performance drop with time is key in order to improve the decision-making process when designing future-proof buildings
    • …
    corecore