254 research outputs found

    Die Privat-Gesellschaft Ressource in MĂĽnchen von ihrem Entstehen bis jetzt

    Get PDF

    Analysis and simulation of photon scattering and neutron capture gamma spectra

    Get PDF
    Within this thesis two twin experiments consisting of neutron capture and photon scattering on the neighbour isotopes 77Se / 78Se and 195Pt / 196Pt have been analysed to gain qualitative and quantitative information about the photon strength function and level density in the respective compound nuclei. For the analysis and simulation of both experimental types a new Monte Carlo simulation using a fast and efficient, extreme statistical treatment of radiative nuclear deexcitations, was developed. Furthermore the influence of fluctuations of transition widths on photon scattering were investigated and quantified. It could be shown that those lead to an enhancement of elastic scattering processes. The data analysis of both twin experiments reveals non-Lorentzian extra E1 photon strength below the neutron separation energy

    Description of dipole strength in heavy nuclei in conformity with their quadrupole degrees of freedom

    Full text link
    In conformity to new findings about the widespread occurrence of triaxiality arguments are given in favor of a description of the giant dipole resonance in heavy nuclei by the sum of three Lorentzians. This TLO parameterization allows a strict use of resonance widths {\Gamma} in accordance to the theoretically founded power law relation to the resonance energy. No additional variation of {\Gamma} with the photon energy and no violation of the sum rule are necessary to obtain a good agreement to nuclear photo-effect, photon scattering and radiative capture data. Photon strength other than E1 has a small effect, but the influence of the level density on photon emission probabilities needs further investigation.Comment: Presented at the 3rd International Workshop on Compound Nuclear Reactions and Related Topics at Prague, 2011, to be published via the EPJ Web of Conference

    Blood Product Supply on Germany: The Impact of Apheresis and Pooled Platelet Concentrates

    Get PDF
    Background: In Germany, about 60% of all produced platelet concentrates (PCs) are apheresis PCs (APCs). Ongoing discussions on APC reimbursement and costs might lead to a potential shift in pooled PC (PPC)/APC production. Objective of this analysis was to build a comprehensive model from the societal perspective to evaluate consequences associated with shifts in platelet supply and demand. Methods: Literature search, desktop researches on platelet supply and demand. Model calculations, time horizon one year: model input from the Paul Ehrlich -Institute, data 2013. Base case: 19.2% of annual whole blood donations (WBDs) were used for production of 38.5% PPCs, decay of 46,218 PCs (8.0%). Scenarios calculated: variation in PPC proportion of 10-100%. Results: Base case: during PPC production 41,957-83,913 red blood cell concentrates (RBCCs) are estimated to be lost, which corresponds to 1-2% of annual RBCCs in Germany. Scenarios were calculated for a production of 60-100% PPCs: loss is estimated to be 1.5-5.0% of annual RBCCs (65,430-218,099), decay 54,189-69,022 PCs (9.4-12.0%). Conclusion: Production of different blood components is interlinked and sensitive to unidimensional decisions. Increasing PPC proportion has negative impact on the RBCC production and on the antigen-matched APC donor pool. Completion of the model calculations to predict the optimal PPC/APC proportion would require evidence on the number of refractory patients, donor pool sizes, and incidences of diseases requiring platelet transfusions. (C) 2016 S. Karger GmbH, Freibur

    Percutaneous aortic valve replacement: valvuloplasty studies in vitro

    Get PDF
    Objective: Valvuloplasty of the aortic valve is currently used in selected patients for severe calcified aortic valve disease, but clinical effectiveness is low and complication rate remains high. In this study, the total particle load after valvuloplasty and the embolization risk of calcific debris into the coronary arteries was analyzed in an in vitro model. Methods: Three highly calcified human aortic leaflets have been sutured into a porcine annulus (N=9). Both coronary arteries were separated and each was anastomized to a silicon line, which was drained off into a measuring beaker. Then valvuloplasty was performed (Thyshak II, 20mm, 1.5atm). After removal of the balloon, 100ml of sodium chloride solution irrigated the ascending aorta. After passing through the separated coronary arteries, the solution was filtered (filter size 0.45ÎĽm), dried, and the total amount of particles was analyzed microscopically. Results: Nine experiments were analyzed. After valvuloplasty, all hearts showed a median of 18 particles larger than 1mm in the coronary arteries (range 0-307). The amount of particles smaller than 1mm was 6574 (median, range 2207-14200). In five cases, coronary arteries were completely occluded by bulky particles. Conclusion: This study demonstrated a large amount of calcific particles after valvuloplasty with a consequently high risk for coronary embolic events in case of highly calcified aortic valves. In times of valvuloplasty rediscovering as part of transcatheter valve implantation, the risk of embolization should be taken into consideration and filtering techniques have to be develope

    Neutron total cross section measurements of gold and tantalum at the nELBE photoneutron source

    Full text link
    Neutron total cross sections of 197^{197}Au and nat^\text{nat}Ta have been measured at the nELBE photoneutron source in the energy range from 0.1 - 10 MeV with a statistical uncertainty of up to 2 % and a total systematic uncertainty of 1 %. This facility is optimized for the fast neutron energy range and combines an excellent time structure of the neutron pulses (electron bunch width 5 ps) with a short flight path of 7 m. Because of the low instantaneous neutron flux transmission measurements of neutron total cross sections are possible, that exhibit very different beam and background conditions than found at other neutron sources.Comment: article (18 pages, 10 figures, 2 tables) with attached data tables (13 pages

    Automation and data processing with the immucor Galileo (R) system in a university blood bank

    Get PDF
    Background: The implementation of automated techniques improves the workflow and quality of immuno-hematological results. The workflows of our university blood bank were reviewed during the implementation of an automated immunohematological testing system. Methods: Work impact of blood grouping and subgrouping, cross- matching and antibody search using the Immucor Galileo system was compared to the previous used standard manual and semi- automated methods. Results: The redesign of our workflow did not achieve a significant reduction of the specimen's working process time, the operator's time however was reduced by 23%. Corresponding results were achieved for blood grouping, Rhesus typing, antibody screen and for autocontrol when changing from two semi- automated to the Galileo system. Because of the higher sensitivity of the Immucor antibody detection system, the rate of the initial positive antibody screens rose from 4 to 6% Conclusion: The Immucor Galileo system automates routine blood bank testing with high reliability, specificity and higher sensitivity compared to our previous used standard manual and semi- automated methods
    • …
    corecore