86 research outputs found

    Cardiac Pacemaker Battery Discharge After External Electrical Cardioversion for Broad QRS Complex Tachycardia

    Get PDF
    External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or cardioversion must be attempted in a patient with a PM or ICD, some precautions should be taken, particularly in PM dependent patients, in order to prevent damage to the device. We report the case of a 76-year-old woman with a dual chamber PM implanted in the right subclavicular region, who received two consecutive transthoracic DC shocks to treat haemodynamically unstable broad QRS complex tachycardia after cardiac surgery performed with a standard sternotomic approach. Because of the sternal wound and thoracic drainage tubes together with the severe clinical compromise, the anterior paddle was positioned near the pulse generator. At the following PM test, a complete battery discharge was detected

    Cardiac pacemaker battery discharge after external electrical cardioversion for broad QRS Complex Tachycardia

    Get PDF
    External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or cardioversion must be attempted in a patient with a PM or ICD, some precautions should be taken, particularly in PM dependent patients, in order to prevent damage to the device. We report the case of a 76-year-old woman with a dual chamber PM implanted in the right subclavicular region, who received two consecutive transthoracic DC shocks to treat haemodynamically unstable broad QRS complex tachycardia after cardiac surgery performed with a standard sternotomic approach. Because of the sternal wound and thoracic drainage tubes together with the severe clinical compromise, the anterior paddle was positioned near the pulse generator. At the following PM test, a complete battery discharge was detected

    Automated conduction velocity estimation based on isochronal activation of heart chambers

    Get PDF
    Background Spatial differences in conduction velocity (CV) are critical for cardiac arrhythmias induction. We propose a method for an automated CV calculation to identify areas of slower conduction during cardiac arrhythmias and sinus rhythm.Methods Color-coded representations of the isochronal activation map using data coming from the RHYTHMIA (TM) Mapping System were reproduced by applying a temporal isochronal window at 20 ms. Geodesic distances of the 3D mesh were calculated using an algorithm selecting the minimum distance pathway (MDP). The CV estimation was performed considering points on the boundary of two spatially and temporally adjacent isochrones. For each of the boundary points of a given isochrone, the nearest boundary point of the consecutive isochrone was chosen, the MDP was evaluated, and a map of CV was created. The proposed method has been applied to a population of 29 patients.Results In all cases of perimitral atrial flutter (16 pts out of 29 (55%)), areas with significantly low CV (< 30 cm/s) were found. Half of the cases present regions with low CV located in the anterior wall. No case with low CV at the so-called LA isthmus was observed. Right atrial maps during common atrial flutters showed low CV areas mainly located in the inferior inter-atrial septum. No areas of low CV were observed in subjects without a history of atrial arrhythmia while pts affected by paroxysmal AF showed areas with a limited extension of low CV.Conclusions The proposed software for automated CV estimation allows the identification of low CV areas, potentially helping electrophysiologists to plan the ablation strategy

    Coexistence of Vagus Nerve Stimulation and Epicardial Implantable Cardioverter-Defibrillator System, Possible Interference: A Case Report and Systematic Review of the Literature

    Get PDF
    Vagus nerve stimulation (VNS) is an effective treatment for drug-resistant epilepsies in adults [1] and children [2]. Although VNS is generally well tolerated, rare cases of severe bradycardia..

    Successful ventricular tachycardia radioablation in a patient with previous chemical pleurodesis: A case report

    Get PDF
    IntroductionStereotactic arrhythmia radioablation (STAR) is a novel technique for the ablation of ventricular tachycardia in patients with contraindications to standard procedures, i.e., radiofrequency ablation.Case presentationWe report the case of a 73-year-old man with non-ischemic dilated cardiomyopathy and recurrent VT episodes. Electroanatomic mapping showed VT prevalently of epicardial origin, but direct epicardial access through subxyphoid puncture could not be performed due to pleuropericardial adhesions from a past history of chemical pleurodesis. STAR was performed, with no VT recurrence at 6 months follow-up.ConclusionsPrevious experiences with STAR have demonstrated its importance in the management of patients with refractory VT in whom other ablation strategies were not successful. Our case report highlights the use of STAR as a second choice in a patient with an unfavorable VT anatomical location and technical limitations to an optimal radiofrequency ablation. Moreover, it confirms STAR's effectiveness in the ablation of complex transmural lesions, which are more often associated with non-ischemic structural heart disease

    Endo-Epicardial Homogenization of the Scar Versus Limited Substrate Ablation for the Treatment of Electrical Storms in Patients With Ischemic Cardiomyopathy

    Get PDF
    ObjectivesThis study investigated the impact on recurrences of 2 different substrate approaches for the treatment of these arrhythmias.BackgroundCatheter ablation of electrical storms (ES) for ventricular arrhythmias (VAs) has shown moderate long-term efficacy in patients with ischemic cardiomyopathy.MethodsNinety-two consecutive patients (81% male, age 62 ± 13 years) with ischemic cardiomyopathy and ES underwent catheter ablation. Patients were treated either by confining the radiofrequency lesions to the endocardial surface with limited substrate ablation (Group 1, n = 49) or underwent endocardial and epicardial ablation of abnormal potentials within the scar (homogenization of the scar, Group 2, n = 43). Epicardial access was obtained in all Group 2 patients, whereas epicardial ablation was performed in 33% (14) of these patients.ResultsMean ejection fraction was 27 ± 5. During a mean follow-up of 25 ± 10 months, the VAs recurrence rate of any ventricular tachycardia (VTs) was 47% (23 of 49 patients) in Group 1 and 19% (8 of 43 patients) in Group 2 (log-rank p = 0.006). One patient in Group 1 and 1 patient in Group 2 died at follow-up for noncardiac reasons.ConclusionsOur study demonstrates that ablation using endo-epicardial homogenization of the scar significantly increases freedom from VAs in ischemic cardiomyopathy patients

    High-dose daptomycin for cardiac implantable electronic device-related infective endocarditis caused by staphylococcal small-colony variants

    No full text
    High-dose daptomycin for cardiac implantable electronic device-related infective endocarditis caused by staphylococcal small-colony variant

    Mid-Term Outcome of Ventricular Arrhythmias Catheter Ablation in Patients with Chronic Coronary Total Occlusion Compared to Ischemic and Non-Ischemic Patients

    No full text
    Chronic coronary total occlusions (CTO) are considered an emerging predictor of ventricular arrhythmias (VAs), but currently there are few data on arrhythmic outcomes in patients affected by CTO undergoing radiofrequency catheter ablation of VAs. This study sought to evaluate the impact of unrevascularized CTO on the recurrence of VAs after catheter ablation. This was a single-center retrospective study enrolling 120 patients between 2015 and 2020. All patients were admitted for ventricular tachycardia (VT) or high premature ventricular contractions burden (>25% detected by Holter ECG), without evidence of acute coronary syndrome; they underwent coronary angiography, electrophysiology (EP) study, and three-dimensional electroanatomic mapping (3D-EAM) followed by VAs ablation. Twenty-eight patients (23%) of 120 patients showed CTO at coronary angiography. At baseline, the CTO group presented with higher prevalence of hypertension, chronic renal disease, systolic ventricular dysfunction, secondary prevention ICD implantation, and higher rate of LAVA by 3D-EAM compared with the non-CTO group. At a median follow-up of 15 months (range 1–96 months) after catheter ablation, the only independent predictor of VAs recurrence was the presence of moderate to severe left ventricular (LV) dysfunction. Therefore, the presence of CTO does not predict VAs recurrence after catheter ablation, which is instead predicted by LV dysfunction
    corecore