487 research outputs found

    Characterisation and calibration of a scintillating fibre detector with > 4000 multi-anode photomultiplier channels

    Full text link
    In the Kaos spectrometer at the Mainz Microtron a high-resolution coordinate detector for high-energy particles is operated. It consists of scintillating fibres with diameters of 4000 multi-anode photomultiplier channels. It is one of the most modern focal-plane detectors for magnetic spectrometers world-wide. To correct variations in the detection efficiency, caused by the different gains and the different optical transmittances, a fully automated off-line calibration procedure has been developed. The process includes the positioning of a radioisotope source alongside the detector plane and the automated acquisition and analysis of the detector signals. It was possible to characterise and calibrate each individual fibre channel with a low degree of human interaction.Comment: Nucl. Instrum. Meth. A (2012

    El cotilo de impactación en las artroplastias de cadera

    Get PDF
    Entre los diferentes sistemas de fijación de la cúpula acetabular entre las artroplastias no cementadas, la impactación tiene múltiples ventajas. Permite un mejor contacto entre implante y hueso y no necesita destrucción de la superficie ósea receptora. Los nuevos diseños para impactación están fabricados en aleaciones de titanio y poseen una superficie rugosa recubierta a su vez con hidroxiapatita. Algunos modelos como la artroplatia Bihapro poseen aletas estabilizadoras en su reborde externo para evitar la movilización rotatoria inicial. El sistema de impactación está mostrando buenos resultados de la experiencia conocida y aunque los periodos de seguimiento son aún cortos, la integración ósea conseguida es satisfactoria. Se presentan los resultados de 1107 cúpulas Bihapro con una evolución entre uno y siete años, que han seguido un protocolo de seguimiento informatizado. En sólo un caso se presentó movilización del componente que precisó cirugía de revisión.The acetabular fixation by impaction has advantages on other systems of fixing in the cementless arthroplaties of the hip. Permit a better contact between implant and bone and it does not need destruction of the receiving bony surface. The new designs for fixation by impaction are manufactured in titanium alloys and possess a rugged surface cover at the same time with hyrdoxiapatite-coated. Some models as the arthroplasty Bihapro possess fins for primary stability in your external curbing to avoid the initial rotary mobilization. This system of fixation is showing good results in the known experience and though the periods of follow-up are yet short, the obtained bony integration is satisfactory. We presented the results of 117 Bihapro cups implanted with a follow-up from one to seven years, that they have followed a computed protocol. In only a case was presented loosening of the component that specified review surgery

    Osteonecrosis del platillo tibial interno: A propósito de dos casos

    Get PDF
    Presentamos dos casos de osteonecrosis idiomática del platillo tibial interno que aparecieron en mujeres. En ellas se dieron las características clínicas habituales de la enfermedad (inicio súbito de dolor intenso en rodilla sin traumatismo previo claramente diferenciado y marcada sensibilidad local en la zona interna de la rodilla) junto a radiografías iniciales normales ó con leves cambios degenerativos (gammagrafía ósea y/ó resonancia magnética nuclear.) En las dos pacientes el proceso evolucionó hacia una gonalgia intensa resistente a la medicación y con cambios degenerativos asociados y fue necesaria la implantación de sendas artroplastias totales de rodilla.We report two cases of osteonocrosis of the medial tibial plateau with typical symptoms (sudden onset of pain at the knee, and marked tenderness over the medial tibial plateau). Initial roentgenograms are within normal limits or showed mild degenerative joint changes, being necessary a magnetic resonance imaging to achieve a diagnosis. The two cases we report didn't follow the typical evolution of the process (which is self-limiting in a period of 6 to 12 months), being necessary in both of them, a total knee replacement

    Liberación de la patela en las artroplastias totales de rodilla: estudio gammagráfico

    Get PDF
    Se han realizado estudios gammagráficos en 20 pacientes intervenidos de artroplastia total cementada de rodilla. En 10 casos fue necesaria la liberación del alerón rotuliano externo y en otros 10 no se había indicado dicho gesto quirúrgico. En ningún paciente existía alteración evolutiva del aparato extensor. Los estudios gammagráficos se practicaron a los 12 meses del implante con el objeto de valorar la situación vascular de la rótula en ese momento. Se comparó, en la proyección lateral, la captación de la rótula en relación a la metáfisis distal del fémur homolateral. No hemos encontrado diferencias entre ambos grupos por lo que consideramos que la liberación patelar no produce un déficit vascular rotuliano a los 12 meses de la cirugía.Scintigraphic studies were performed in 20 patients with cemented total prosthesis of the knee. The patellar release was necessary in 10 cases. None of the patients developed knee extension deficits. Scintigraphic studies were performed 12 months after surgery in order to know the patellar blood supply at that moment. Patellar isotopic uptake was compared with the uptake at the distal metaphysis of the homolateral femur, at lateral projection. We haven't found any differences between both groups, so we consider that the patellar release doesn't make a less blood supply twelve months after surgery

    High-precision determination of the electric and magnetic form factors of the proton

    Get PDF
    New precise results of a measurement of the elastic electron-proton scattering cross section performed at the Mainz Microtron MAMI are presented. About 1400 cross sections were measured with negative four-momentum transfers squared up to Q^2=1 (GeV/c)^2 with statistical errors below 0.2%. The electric and magnetic form factors of the proton were extracted by fits of a large variety of form factor models directly to the cross sections. The form factors show some features at the scale of the pion cloud. The charge and magnetic radii are determined to be r_E=0.879(5)(stat.)(4)(syst.)(2)(model)(4)(group) fm and r_M=0.777(13)(stat.)(9)(syst.)(5)(model)(2)(group) fm.Comment: 5 pages, 2 figures, published in Phys. Rev. Lett. v3: added references, updated text, color figure

    Reply to Comment on "High-Precision Determination of the Electric and Magnetic Form Factors of the Proton"

    Get PDF
    In arXiv:1108.3058v1 [nucl-ex], Arrington criticizes the Coulomb corrections we applied in the analysis of high precision form factor data (see Phys.Rev.Lett.105:242001, 2010, arXiv:1007.5076v3 [nucl-ex]). We show, by comparing different calculations cited in the Comment, that the criticism of the Comment neglects the large uncertainty of "more modern" TPE corrections. This uncertainty has also been seen in recent polarized measurements. We rerun our analysis using one of these calculations. The results show that the Comment exaggerates the quantitative effect at small Q^2.Comment: 1 page, 2 figure, To appear as a Reply Comment in Physical Review Letter

    The electric and magnetic form factors of the proton

    Get PDF
    The paper describes a precise measurement of electron scattering off the proton at momentum transfers of 0.003Q210.003 \lesssim Q^2 \lesssim 1\ GeV2^2. The average point-to-point error of the cross sections in this experiment is \sim 0.37%. These data are used for a coherent new analysis together with all world data of unpolarized and polarized electron scattering from the very smallest to the highest momentum transfers so far measured. The extracted electric and magnetic form factors provide new insight into their exact shape, deviating from the classical dipole form, and of structure on top of this gross shape. The data reaching very low Q2Q^2 values are used for a new determination of the electric and magnetic radii. An empirical determination of the Two-Photon-Exchange (TPE) correction is presented. The implications of this correction on the radii and the question of a directly visible signal of the pion cloud are addressed.Comment: 38 pages, 20 figures. Updated data files. PRC versio

    Recoil polarization and beam-recoil double polarization measurement of \eta electroproduction on the proton in the region of the S_{11}(1535) resonance

    Get PDF
    The beam-recoil double polarization P_{x'}^h and P_{z'}^h and the recoil polarization P_{y'} were measured for the first time for the p(\vec{e},e'\vec{p})\eta reaction at a four-momentum transfer of Q^2=0.1 GeV^2/c^2 and a center of mass production angle of \theta = 120^\circ at MAMI C. With a center of mass energy range of 1500 MeV < W < 1550 MeV the region of the S_{11}(1535) and D_{13}(1520) resonance was covered. The results are discussed in the framework of a phenomenological isobar model (Eta-MAID). While P_{x'}^h and P_{z'}^h are in good agreement with the model, P_{y'} shows a significant deviation, consistent with existing photoproduction data on the polarized-target asymmetry.Comment: 4 pages, 1 figur
    corecore