3,082 research outputs found

    A table-top, repetitive pulsed magnet for nonlinear and ultrafast spectroscopy in high magnetic fields up to 30 T

    Full text link
    We have developed a mini-coil pulsed magnet system with direct optical access, ideally suited for nonlinear and ultrafast spectroscopy studies of materials in high magnetic fields up to 30 T. The apparatus consists of a small coil in a liquid nitrogen cryostat coupled with a helium flow cryostat to provide sample temperatures down to below 10 K. Direct optical access to the sample is achieved with the use of easily interchangeable windows separated by a short distance of ~135 mm on either side of the coupled cryostats with numerical apertures of 0.20 and 0.03 for measurements employing the Faraday geometry. As a demonstration, we performed time-resolved and time-integrated photoluminescence measurements as well as transmission measurements on InGaAs quantum wells.Comment: 7 pages, 6 figure

    DataViewer3D: An Open-Source, Cross-Platform Multi-Modal Neuroimaging Data Visualization Tool

    Get PDF
    Integration and display of results from multiple neuroimaging modalities [e.g. magnetic resonance imaging (MRI), magnetoencephalography, EEG] relies on display of a diverse range of data within a common, defined coordinate frame. DataViewer3D (DV3D) is a multi-modal imaging data visualization tool offering a cross-platform, open-source solution to simultaneous data overlay visualization requirements of imaging studies. While DV3D is primarily a visualization tool, the package allows an analysis approach where results from one imaging modality can guide comparative analysis of another modality in a single coordinate space. DV3D is built on Python, a dynamic object-oriented programming language with support for integration of modular toolkits, and development of cross-platform software for neuroimaging. DV3D harnesses the power of the Visualization Toolkit (VTK) for two-dimensional (2D) and 3D rendering, calling VTK's low level C++ functions from Python. Users interact with data via an intuitive interface that uses Python to bind wxWidgets, which in turn calls the user's operating system dialogs and graphical user interface tools. DV3D currently supports NIfTI-1, ANALYZE™ and DICOM formats for MRI data display (including statistical data overlay). Formats for other data types are supported. The modularity of DV3D and ease of use of Python allows rapid integration of additional format support and user development. DV3D has been tested on Mac OSX, RedHat Linux and Microsoft Windows XP. DV3D is offered for free download with an extensive set of tutorial resources and example data

    P2Y receptors in the mammalian nervous system: pharmacology, ligands and therapeutic potential

    Get PDF
    P2Y receptors for extracellular nucleotides are coupled to activation of a variety of G proteins and stimulate diverse intracellular signaling pathways that regulate functions of cell types that comprise the central nervous system (CNS). There are 8 different subtypes of P2Y receptor expressed in cells of the CNS that are activated by a select group of nucleotide agonists. Here, the agonist selectivity of these 8 P2Y receptor subtypes is reviewed with an emphasis on synthetic agonists with high potency and resistance to degradation by extracellular nucleotidases that have potential applications as therapeutic agents. In addition, the recent identification of a wide variety of subtype-selective antagonists is discussed, since these compounds are critical for discerning cellular responses mediated by activation of individual P2Y receptor subtypes. The functional expression of P2Y receptor subtypes in cells that comprise the CNS is also reviewed and the role of each subtype in the regulation of physiological and pathophysiological responses is considered. Other topics include the role of P2Y receptors in the regulation of blood-brain barrier integrity and potential interactions between different P2Y receptor subtypes that likely impact tissue responses to extracellular nucleotides in the CNS. Overall, current research suggests that P2Y receptors in the CNS regulate repair mechanisms that are triggered by tissue damage, inflammation and disease and thus P2Y receptors represent promising targets for the treatment of neurodegenerative diseases

    Vacuum ultraviolet instrumentation for solar irradiance and thermospheric airglow

    Get PDF
    A NASA sounding rocket experiment was developed to study the solar extreme ultraviolet (EUV) spectral irradiance and its effect on the upper atmosphere. Both the solar flux and the terrestrial molecular nitrogen via the Lyman-Birge-Hopfield bands in the far ultraviolet (FUV) were measured remotely from a sounding rocket on October 27, 1992. The rocket experiment also includes EUV instruments from Boston University (Supriya Chakrabarti), but only the National Center for Atmospheric Research (NCAR)/University of Colorado (CU) four solar instruments and one airglow instrument are discussed here. The primary solar EUV instrument is a 1/4 meter Rowland circle EUV spectrograph which has flown on three rockets since 1988 measuring the solar spectral irradiance from 30 to 110 nm with 0.2 nm resolution. Another solar irradiance instrument is an array of six silicon XUV photodiodes, each having different metallic filters coated directly on the photodiodes. This photodiode system provides a spectral coverage from 0.1 to 80 nm with about 15 nm resolution. The other solar irradiance instrument is a silicon avalanche photodiode coupled with pulse height analyzer electronics. This avalanche photodiode package measures the XUV photon energy providing a solar spectrum from 50 to 12,400 eV (25 to 0.1 nm) with an energy resolution of about 50 eV. The fourth solar instrument is an XUV imager that images the sun at 17.5 nm with a spatial resolution of 20 arc-seconds. The airglow spectrograph measures the terrestrial FUV airglow emissions along the horizon from 125 to 160 nm with 0.2 nm spectral resolution. The photon-counting CODACON detectors are used for three of these instruments and consist of coded arrays of anodes behind microchannel plates. The one-dimensional and two-dimensional CODACON detectors were developed at CU by Dr. George Lawrence. The pre-flight and post-flight photometric calibrations were performed at our calibration laboratory and at the Synchrotron Ultraviolet Radiation Facility (SURF) at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland

    Ferrichrome: Surprising stability of a cyclic peptide-FeIII complex revealed by mass spectrometry

    Get PDF
    Ferrichrome, a fungal siderophore that is also utilized by some bacterial species, was studied with liquid secondary ion mass spectrometry (LSIMS) and matrix-assisted laser desorption ionixation (MALDI) mass spectrometry. A strong ionic signal corresponding to a FeIII complex was observed with LSIMS in the positive ion mode. Switching the polarity of the mass spectrometer did not necessarily result in reduction of ferric ion, although certain conditions led to appearance of a FeII complex signal as well. The results of the structural studies of the metal ion-cyclic peptide complex with collisionally induced dissociation allowed unambiguous identification of the chelation sites. The action of the siderophore on FeIII was studied by in vitro chelation of ferric ion (from ferric citrate) by the iron-free ferrichrome. Effective chelation of ferric ion was compared to actions of the iron-free ferrichrome on other metal ions. Unlike LSIMS, desorption with MALDI did not form selectively molecular ions of intact ferrichrome: the spectra contained abundant peaks corresponding to the cyclic peptide itself and its nonspecific association with alkali metal ions

    Stimulus Variability Affects the Amplitude of the Auditory Steady-State Response

    Get PDF
    In this study we investigate whether stimulus variability affects the auditory steady-state response (ASSR). We present cosinusoidal AM pulses as stimuli where we are able to manipulate waveform shape independently of the fixed repetition rate of 4 Hz. We either present sounds in which the waveform shape, the pulse-width, is fixed throughout the presentation or where it varies pseudo-randomly. Importantly, the average spectra of all the fixed-width AM stimuli are equal to the spectra of the mixed-width AM. Our null hypothesis is that the average ASSR to the fixed-width AM will not be significantly different from the ASSR to the mixed-width AM. In a region of interest beamformer analysis of MEG data, we compare the 4 Hz component of the ASSR to the mixed-width AM with the 4 Hz component of the ASSR to the pooled fixed-width AM. We find that at the group level, there is a significantly greater response to the variable mixed-width AM at the medial boundary of the Middle and Superior Temporal Gyri. Hence, we find that adding variability into AM stimuli increases the amplitude of the ASSR. This observation is important, as it provides evidence that analysis of the modulation waveform shape is an integral part of AM processing. Therefore, standard steady-state studies in audition, using sinusoidal AM, may not be sensitive to a key feature of acoustic processing

    Predicting Extrapunitive And Intropunitive Hostility In A Juvenile Correction Population

    Get PDF
    This study examined the thesis that extrapunitive and intropunitive hostility can be predicted in a juvenile corrections subject population using a projective technique

    Magnetic and electronic properties of Eu\u3csub\u3e4\u3c/sub\u3eSr\u3csub\u3e4\u3c/sub\u3eGa\u3csub\u3e16\u3c/sub\u3eGe\u3csub\u3e30\u3c/sub\u3e

    Get PDF
    Magnetization, static and ac magnetic susceptibility, nuclear forward scattering, and electrical resistivity measurements have been performed on polycrystalline Eu4Sr4Ga16Ge30, a type I clathrate that has divalent strontium and europium ions encapsulated within a Ga-Ge framework. These data are compared with those of type I clathrates Eu8Ga16Ge30 and Eu6Sr2Ga16Ge30. The ferromagnetic ordering of these Eu-containing clathrates is substantially altered by the incorporation of strontium, as compared to Eu8Ga16Ge30. Ferromagnetism, accompanied by a relatively large negative magnetoresistance, is observed below 15 and 20 K in Eu4Sr4Ga16Ge30 and Eu6Sr2Ga16Ge30, respectively. An effective magnetic moment of 7.83 μB per Eu ion is observed above 30 K for Eu4Sr4Ga16Ge30, a moment which is close to the free-ion moment of 7.94 μB per europium(II) ion
    corecore