9 research outputs found

    Comparación de tensiones y desplazamientos entre mini-implantes de acero y titanio insertados con diferentes angulaciones: análisis de elementos finitos

    Get PDF
    Objective: The objective of this study was to quantify the tensions and displacements of steel and titanium mini-implants inserted at different angles and under a retraction force. Materials and Methods: A CAD model of the TD Orthodontics mini-implant was created. The material properties (steel or titanium alloy) were then assigned. SolidWorks software was used to mesh the mini-implant and bone models and perform the finite element analysis on the mini-implants inserted at angles of 30°, 60°, and 90° with a simulated orthodontic retraction force of 2 N applied to each of these finite element models. Results: With regards to the maximum von Mises stress, there appears to be no significant difference between the steel and titanium mini-implants at the evaluated angles. In terms of displacement, the titanium mini-implants generally experienced greater displacement at the three evaluated angles compared to the stainless steel mini-implants.Objectivo: El objetivo de este estudio fue evaluar cuantitativamente las tensiones y desplazamientos de los mini-implantes de acero y titanio insertados bajo diferentes ángulos y aplicando una fuerza de retractación. Materiales y métodos: Se creó un modelo CAD del mini-implante de la marca TD Orthodontics. Posteriormente, se asignaron las características de los materiales a evaluar (acero o aleación de titanio). Se utilizó el software SolidWorks para hacer la malla de los modelos de mini-implante y hueso, y así realizar el análisis de elementos finitos en los mini-implantes con ángulos de inserción de 30°, 60°, 90° y se aplicó una fuerza de retracción ortodóncica simulada de 2 N en cada uno de estos modelos de elementos finitos. Resultados: En cuanto al estrés máximo de von Mises, observamos que parece no haber una diferencia significativa entre los mini-implantes de acero y de titanio en las angulaciones evaluadas. En cuanto al desplazamiento, los mini-implantes de titanio en general sufrieron mayor desplazamiento en las tres angulaciones evaluadas en comparación con los mini implantes de acero inoxidable.&nbsp

    Fibonacci quasiregular graphene-based superlattices: Quasiperiodicity and its effects on the transmission, transport and electronic structure properties

    No full text
    We study the transmission, transport and electronic structure properties of aperiodic Fibonacci monolayer graphene-based structures (AFGBSs). The transfer matrix method has been implemented to obtain the transmittance, linear-regime conductance and electronic structure. In particular, we have studied two types of aperiodic graphene-based structures: (1) electrostatic AFGBSs (EAFGBSs), structures formed with electrostatic potentials, and (2) substrate AFGBSs (SAFGBSs), obtained alternating substrates that can open and non-open, such as SiC and SiO2, an energy bandgap on graphene. We have found that the transmission properties can be modulated readily by changing the main parameters of the systems: well and barrier widths, energy and angle of incident electrons and the degree of aperiodicity. In the case of the linear-regime conductance turns out that it diminishes various orders of magnitude increasing the barrier width for SAFGBSs. On the contrary, Klein tunneling sustains the conductance in EAFGBSs. Calculating the electronic structure or miniband-structure formation and its fragmentation we establish a direct connection between the conductance peaks and the opening, closure and degeneration of energy minibands for both EAFGSLs and SAFGSLs

    Artificial Enzyme-Powered Microfish for Water-Quality Testing

    No full text
    We present a novel micromotor-based strategy for water-quality testing based on changes in the propulsion behavior of artificial biocatalytic microswimmers in the presence of aquatic pollutants. The new micromotor toxicity testing concept mimics live-fish water testing and relies on the toxin-induced inhibition of the enzyme catalase, responsible for the biocatalytic bubble propulsion of tubular microengines. The locomotion and survival of the artificial microfish are thus impaired by exposure to a broad range of contaminants, that lead to distinct time-dependent irreversible losses in the catalase activity, and hence of the propulsion behavior. Such use of enzyme-powered biocompatible polymeric (PEDOT)/Au-catalase tubular microengine offers highly sensitive direct optical visualization of changes in the swimming behavior in the presence of common contaminants and hence to a direct real-time assessment of the water quality. Quantitative data on the adverse effects of the various toxins upon the swimming behavior of the enzyme-powered artificial swimmer are obtained by estimating common ecotoxicological parameters, including the EC<sub>50</sub> (exposure concentration causing 50% attenuation of the microfish locomotion) and the swimmer survival time (lifetime expectancy). Such novel use of artificial microfish addresses major standardization and reproducibility problems as well as ethical concerns associated with live-fish toxicity assays and hence offers an attractive alternative to the common use of aquatic organisms for water-quality testing

    Artificial Enzyme-Powered Microfish for Water-Quality Testing

    No full text
    We present a novel micromotor-based strategy for water-quality testing based on changes in the propulsion behavior of artificial biocatalytic microswimmers in the presence of aquatic pollutants. The new micromotor toxicity testing concept mimics live-fish water testing and relies on the toxin-induced inhibition of the enzyme catalase, responsible for the biocatalytic bubble propulsion of tubular microengines. The locomotion and survival of the artificial microfish are thus impaired by exposure to a broad range of contaminants, that lead to distinct time-dependent irreversible losses in the catalase activity, and hence of the propulsion behavior. Such use of enzyme-powered biocompatible polymeric (PEDOT)/Au-catalase tubular microengine offers highly sensitive direct optical visualization of changes in the swimming behavior in the presence of common contaminants and hence to a direct real-time assessment of the water quality. Quantitative data on the adverse effects of the various toxins upon the swimming behavior of the enzyme-powered artificial swimmer are obtained by estimating common ecotoxicological parameters, including the EC<sub>50</sub> (exposure concentration causing 50% attenuation of the microfish locomotion) and the swimmer survival time (lifetime expectancy). Such novel use of artificial microfish addresses major standardization and reproducibility problems as well as ethical concerns associated with live-fish toxicity assays and hence offers an attractive alternative to the common use of aquatic organisms for water-quality testing

    Artificial Enzyme-Powered Microfish for Water-Quality Testing

    No full text
    We present a novel micromotor-based strategy for water-quality testing based on changes in the propulsion behavior of artificial biocatalytic microswimmers in the presence of aquatic pollutants. The new micromotor toxicity testing concept mimics live-fish water testing and relies on the toxin-induced inhibition of the enzyme catalase, responsible for the biocatalytic bubble propulsion of tubular microengines. The locomotion and survival of the artificial microfish are thus impaired by exposure to a broad range of contaminants, that lead to distinct time-dependent irreversible losses in the catalase activity, and hence of the propulsion behavior. Such use of enzyme-powered biocompatible polymeric (PEDOT)/Au-catalase tubular microengine offers highly sensitive direct optical visualization of changes in the swimming behavior in the presence of common contaminants and hence to a direct real-time assessment of the water quality. Quantitative data on the adverse effects of the various toxins upon the swimming behavior of the enzyme-powered artificial swimmer are obtained by estimating common ecotoxicological parameters, including the EC<sub>50</sub> (exposure concentration causing 50% attenuation of the microfish locomotion) and the swimmer survival time (lifetime expectancy). Such novel use of artificial microfish addresses major standardization and reproducibility problems as well as ethical concerns associated with live-fish toxicity assays and hence offers an attractive alternative to the common use of aquatic organisms for water-quality testing

    Artificial Enzyme-Powered Microfish for Water-Quality Testing

    No full text
    We present a novel micromotor-based strategy for water-quality testing based on changes in the propulsion behavior of artificial biocatalytic microswimmers in the presence of aquatic pollutants. The new micromotor toxicity testing concept mimics live-fish water testing and relies on the toxin-induced inhibition of the enzyme catalase, responsible for the biocatalytic bubble propulsion of tubular microengines. The locomotion and survival of the artificial microfish are thus impaired by exposure to a broad range of contaminants, that lead to distinct time-dependent irreversible losses in the catalase activity, and hence of the propulsion behavior. Such use of enzyme-powered biocompatible polymeric (PEDOT)/Au-catalase tubular microengine offers highly sensitive direct optical visualization of changes in the swimming behavior in the presence of common contaminants and hence to a direct real-time assessment of the water quality. Quantitative data on the adverse effects of the various toxins upon the swimming behavior of the enzyme-powered artificial swimmer are obtained by estimating common ecotoxicological parameters, including the EC<sub>50</sub> (exposure concentration causing 50% attenuation of the microfish locomotion) and the swimmer survival time (lifetime expectancy). Such novel use of artificial microfish addresses major standardization and reproducibility problems as well as ethical concerns associated with live-fish toxicity assays and hence offers an attractive alternative to the common use of aquatic organisms for water-quality testing

    Superhydrophobic Alkanethiol-Coated Microsubmarines for Effective Removal of Oil

    No full text
    We demonstrate the use of artificial nanomachines for effective interaction, capture, transport, and removal of oil droplets. The simple nanomachine-enabled oil collection method is based on modifying microtube engines with a superhydrophobic layer able to adsorb oil by means of its strong adhesion to a long chain of self-assembled monolayers (SAMs) of alkanethiols created on the rough gold outer surface of the device. The resultant SAM-coated Au/Ni/PEDOT/Pt microsubmarine displays continuous interaction with large oil droplets and is capable of loading and transporting multiple small oil droplets. The influence of the alkanethiol chain length, polarity, and head functional group and hence of the surface hydrophobicity upon the oil–nanomotor interaction and the propulsion is examined. No such oil–motor interactions were observed in control experiments involving both unmodified microengines and microengines coated with SAM layers containing a polar terminal group. These results demonstrate that such SAM-Au/Ni/PEDOT/Pt micromachines can be useful for a facile, rapid, and efficient collection of oils in water samples, which can be potentially exploited for other water–oil separation systems. The integration of oil-sorption properties into self-propelled microengines holds great promise for the remediation of oil-contaminated water samples and for the isolation of other hydrophobic targets, such as drugs

    Correction: Evolving Trends in the Management of Acute Appendicitis During COVID-19 Waves: The ACIE Appy II Study

    No full text
    Background: In 2020, ACIE Appy study showed that COVID-19 pandemic heavily affected the management of patients with acute appendicitis (AA) worldwide, with an increased rate of non-operative management (NOM) strategies and a trend toward open surgery due to concern of virus transmission by laparoscopy and controversial recommendations on this issue. The aim of this study was to survey again the same group of surgeons to assess if any difference in management attitudes of AA had occurred in the later stages of the outbreak. Methods: From August 15 to September 30, 2021, an online questionnaire was sent to all 709 participants of the ACIE Appy study. The questionnaire included questions on personal protective equipment (PPE), local policies and screening for SARS-CoV-2 infection, NOM, surgical approach and disease presentations in 2021. The results were compared with the results from the previous study. Results: A total of 476 answers were collected (response rate 67.1%). Screening policies were significatively improved with most patients screened regardless of symptoms (89.5% vs. 37.4%) with PCR and antigenic test as the preferred test (74.1% vs. 26.3%). More patients tested positive before surgery and commercial systems were the preferred ones to filter smoke plumes during laparoscopy. Laparoscopic appendicectomy was the first option in the treatment of AA, with a declined use of NOM. Conclusion: Management of AA has improved in the last waves of pandemic. Increased evidence regarding SARS-COV-2 infection along with a timely healthcare systems response has been translated into tailored attitudes and a better care for patients with AA worldwide

    Safety of hospital discharge before return of bowel function after elective colorectal surgery

    No full text
    Background Ileus is common after colorectal surgery and is associated with an increased risk of postoperative complications. Identifying features of normal bowel recovery and the appropriateness for hospital discharge is challenging. This study explored the safety of hospital discharge before the return of bowel function. Methods A prospective, multicentre cohort study was undertaken across an international collaborative network. Adult patients undergoing elective colorectal resection between January and April 2018 were included. The main outcome of interest was readmission to hospital within 30 days of surgery. The impact of discharge timing according to the return of bowel function was explored using multivariable regression analysis. Other outcomes were postoperative complications within 30 days of surgery, measured using the Clavien-Dindo classification system. Results A total of 3288 patients were included in the analysis, of whom 301 (9 center dot 2 per cent) were discharged before the return of bowel function. The median duration of hospital stay for patients discharged before and after return of bowel function was 5 (i.q.r. 4-7) and 7 (6-8) days respectively (P &lt; 0 center dot 001). There were no significant differences in rates of readmission between these groups (6 center dot 6 versus 8 center dot 0 per cent; P = 0 center dot 499), and this remained the case after multivariable adjustment for baseline differences (odds ratio 0 center dot 90, 95 per cent c.i. 0 center dot 55 to 1 center dot 46; P = 0 center dot 659). Rates of postoperative complications were also similar in those discharged before versus after return of bowel function (minor: 34 center dot 7 versus 39 center dot 5 per cent; major 3 center dot 3 versus 3 center dot 4 per cent; P = 0 center dot 110). Conclusion Discharge before return of bowel function after elective colorectal surgery appears to be safe in appropriately selected patients
    corecore