24 research outputs found

    A Lateral Flow Protein Microarray for Rapid and Sensitive Antibody Assays

    Get PDF
    Protein microarrays are useful tools for highly multiplexed determination of presence or levels of clinically relevant biomarkers in human tissues and biofluids. However, such tools have thus far been restricted to laboratory environments. Here, we present a novel 384-plexed easy to use lateral flow protein microarray device capable of sensitive (<30 ng/mL) determination of antigen-specific antibodies in ten minutes of total assay time. Results were developed with gold nanobeads and could be recorded by a cell-phone camera or table top scanner. Excellent accuracy with an area under curve (AUC of 98% was achieved in comparison with an established glass microarray assay for 26 antigen-specific antibodies. We propose that the presented framework could find use in convenient and cost-efficient quality control of antibody production, as well as in providing a platform for multiplexed affinity-based assays in low-resource or mobile settings

    Etiology of Clinical Community-Acquired Pneumonia in Swedish Children Aged 1-59 Months with High Pneumococcal Vaccine Coverage-The TREND Study

    Get PDF
    (1) Immunization with pneumococcal conjugate vaccines has decreased the burden of community-acquired pneumonia (CAP) in children and likely led to a shift in CAP etiology. (2) The Trial of Respiratory infections in children for ENhanced Diagnostics (TREND) enrolled children 1-59 months with clinical CAP according to the World Health Organization (WHO) criteria at Sachs' Children and Youth Hospital, Stockholm, Sweden. Children with rhonchi and indrawing underwent "bronchodilator challenge". C-reactive protein and nasopharyngeal PCR detecting 20 respiratory pathogens, were collected from all children. Etiology was defined according to an a priori defined algorithm based on microbiological, biochemical, and radiological findings. (3) Of 327 enrolled children, 107 (32%) required hospitalization; 91 (28%) received antibiotic treatment; 77 (24%) had a chest X-ray performed; and 60 (18%) responded to bronchodilator challenge. 243 (74%) episodes were classified as viral, 11 (3%) as mixed viral-bacterial, five (2%) as bacterial, two (0.6%) as atypical bacterial and 66 (20%) as undetermined etiology. After exclusion of children responding to bronchodilator challenge, the proportion of bacterial and mixed viral-bacterial etiology was 1% and 4%, respectively. (4) The novel TREND etiology algorithm classified the majority of clinical CAP episodes as of viral etiology, whereas bacterial etiology was uncommon. Defining CAP in children <5 years is challenging, and the WHO definition of clinical CAP is not suitable for use in children immunized with pneumococcal conjugate vaccines

    Novel diagnostic microarray assay formats towards comprehensive on-site analysis

    No full text
    Advances in molecular methods for analyzing DNA, RNA and proteins in humans as well as in other animals, plants, fungi, bacteria or viruses have greatly increased the resolution with which we can study life’s complexity and dynamics on earth. While genomic, transcriptomic and proteomic laboratory tools for molecular diagnosis of disease are rapidly becoming more comprehensive, the access to such advanced yet often expensive and centralized procedures is limited. There is a great need for rapid and comprehensive diagnostic methods in low-resource settings or contexts where a person can not or will not go to a hospital or medical laboratory, yet where a clinical analysis is urgent. In this thesis, results from development and characterization of novel technologies for DNA and protein microarray analysis are presented. Emphasis is on methods that could provide rapid, cost-effective and portable analysis with convenient readout and retained diagnostic accuracy. The first study presents a magnetic bead-based approach for DNA microarray analysis for a rapid visual detection of single nucleotide polymorphisms. In the second work, magnetic beads were used as detection reagents for rapid differential detection of presence of pestiviral family members using a DNA oligonucleotide microarray with read-out by means of a tabletop scanner or a digital camera. In paper three, autoimmune responses from human sera were detected on a protein autoantigen microarray, again by means of magnetic bead analysis. Here, special emphasis was made in comprehensively comparing the performance of the magnetic bead detection to common fluorescence-based detection. In the fourth study, an immunochromatographic lateral flow protein microarray assay is presented for application in the classification of contagious pleuropneumonia from bovine serum samples. The analysis could be performed within 10 minutes using a table top scanner, and the performance of the assay was shown to be comparable to that of a cocktail ELISA. In the fifth paper, the lateral flow microarray framework is investigated in further detail by means of experiments and numerical simulation. It was found that downstream effects play an important role, and the results further suggest that the downstream binding profiles may find use in simple affinity evaluation.QC 2010071

    A lateral flow paper microarray for rapid allergy point of care diagnostics

    Get PDF
    There is a growing need for multiplexed specific IgE tests that can accurately evaluate patient sensitization profiles. However, currently available commercial tests are either single/low-plexed or require sophisticated instrumentation at considerable cost per assay. Here, we present a novel convenient lateral flow microarray-based device that employs a novel dual labelled gold nanoparticle-strategy for rapid and sensitive detection of a panel of 15 specific IgE responses in 35 clinical serum samples. Each gold nanoparticle was conjugated to an optimized ratio of HRP and anti-IgE, allowing significant enzymatic amplification to improve the sensitivity of the assay as compared to commercially available detection reagents. The mean inter-assay variability of the developed LFM assay was 12% CV, and analysis of a cohort of clinical samples (n = 35) revealed good general agreement with ImmunoCAP, yet with a varying performance among allergens (AUC = [0.54-0.88], threshold 1 kU). Due to the rapid and simple procedure, inexpensive materials and read-out by means of a consumer flatbed scanner, the presented assay may provide an interesting low-cost alternative to existing multiplexed methods when thresholds > 1 kU are acceptable

    Point-of-care vertical flow allergen microarray assay: proof of concept

    Get PDF
    BACKGROUND:\ud Sophisticated equipment, lengthy protocols, and skilled operators are required to perform protein microarray-based affinity assays. Consequently, novel tools are needed to bring biomarkers and biomarker panels into clinical use in different settings. Here, we describe a novel paper-based vertical flow microarray (VFM) system with a multiplexing capacity of at least 1480 microspot binding sites, colorimetric readout, high sensitivity, and assay time of <10 min before imaging and data analysis. \ud \ud METHOD:\ud Affinity binders were deposited on nitrocellulose membranes by conventional microarray printing. Buffers and reagents were applied vertically by use of a flow controlled syringe pump. As a clinical model system, we analyzed 31 precharacterized human serum samples using the array system with 10 allergen components to detect specific IgE reactivities. We detected bound analytes using gold nanoparticle conjugates with assay time of ≤10 min. Microarray images were captured by a consumer-grade flatbed scanner. \ud \ud RESULTS:\ud A sensitivity of 1 ng/mL was demonstrated with the VFM assay with colorimetric readout. The reproducibility (CV) of the system was <14%. The observed concordance with a clinical assay, ImmunoCAP, was R2 = 0.89 (n = 31). \ud \ud CONCLUSIONS:\ud In this proof-of-concept study, we demonstrated that the VFM assay, which combines features from protein microarrays and paper-based colorimetric systems, could offer an interesting alternative for future highly multiplexed affinity point-of-care testing

    Towards paper-based point of care affinity proteomics

    No full text
    Affinity-based methods such as protein microarrays have come to complement conventional mass/charge-based techniques for proteomic characterization of biological samples. Simultaneous measurement of hundreds or even thousands of serum biomarkers such as antibodies, antigens and other proteins may greatly improve the diagnostic accuracy in a variety of conditions such as autoimmune disorders, infections and several cancers. However, today's technologies for affinity proteomics are cumbersome, require expensive equipment and skilled operators. Here, we present two novel paper-based techniques developed in our lab that aim to bridge the gap between highly multiplexed affinity proteomics and point of care testing

    A 61% lighter cell culture dish to reduce plastic waste.

    No full text
    Cell culture is a ubiquitous and flexible research method. However, it heavily relies on plastic consumables generating millions of tonnes of plastic waste yearly. Plastic waste is a major and growing global concern. Here we describe a new cell culture dish that offers a culture area equivalent to three petri dishes but that is on average 61% lighter and occupies 67% less volume. Our dish is composed of a lid and three thin containers surrounded by a light outer shell. Cell culture can be performed in each of the containers sequentially. The outer shell provides the appropriate structure for the manipulation of the dish as a whole. The prototype was tested by sequentially growing cells in each of its containers. As a control, sequential cultures in groups of 3 petri dishes were performed. No statistical differences were found between the prototype and the control in terms of cell number, cell viability or cell distribution

    A vertical flow paper-microarray assay with isothermal DNA amplification for detection of Neisseria meningitidis

    No full text
    Paper-based biosensors offer a promising technology to be used at the point of care, enabled by good performance, convenience and low-cost. In this article, we describe a colorimetric vertical-flow DNA microarray (DNAVFM) that takes advantage of the screening capability of DNA microarrays in a paper format together with isothermal amplification by means of Recombinase Polymerase Amplification (RPA). Different assay parameters such as hybridization buffer, flow rate, printing buffer and capture probe concentration were optimized. A limit of detection (LOD) of 4.4 nM was achieved as determined by tabletop scanning. The DNA-VFM was applied as a proof of concept for detection of Neisseria meningitidis, a primary cause of bacterial meningitis. The LOD was determined to be between 38 and 2.1 x 10(6) copies/VFMassay, depending on the choice of DNA capture probes. The presented approach provides multiplex capabilities of DNA microarrays in a paper-based format for future point-of-care applications

    Point-of-care testing in a high-income country paediatric emergency department : a qualitative study in Sweden

    No full text
    Objectives: In many resource-limited health systems, point-of-care tests (POCTs) are the only means for clinical patient sample analyses. However, the speed and simplicity of POCTs also makes their use appealing to clinicians in high-income countries (HICs), despite greater laboratory accessibility. Although also part of the clinical routine in HICs, clinician perceptions of the utility of POCTs are relatively unknown in such settings as compared with others. In a Swedish paediatric emergency department (PED) where POCT use is routine, we aimed to characterise healthcare providers' perspectives on the clinical utility of POCTs and explore their implementation in the local setting; to discuss and compare such perspectives, to those reported in other settings; and finally, to gather requests for ideal novel POCTs. Design: Qualitative focus group discussions study. A data-driven content analysis approach was used for analysis. Setting: The PED of a secondary paediatric hospital in Stockholm, Sweden. Participants: Twenty-four healthcare providers clinically active at the PED were enrolled in six focus groups. Results: A range of POCTs was routinely used. The emerging theme Utility of our POCT use is double-edged illustrated the perceived utility of POCTs. While POCT services were considered to have clinical and social value, the local routine for their use was named to distract clinicians from the care for patients. Requests were made for ideal POCTs and their implementation. Conclusion: Despite their clinical integration, deficient implementation routines limit the benefits of POCT services to this well-resourced paediatric clinic. As such deficiencies are shared with other settings, it is suggested that some characteristics of POCTs and of their utility are less related to resource level and more to policy deficiency. To address this, we propose the appointment of skilled laboratory personnel as ambassadors to hospital clinics offering POCT services, to ensure higher utility of such services
    corecore