4,735 research outputs found
High supersonic stability and control characteristics of a 0.015-scale (remotely controlled elevon) model 49-0 of the space shuttle orbiter tested in the NASA/LaRC 4-foot UPWT (LEG 2) (LA63B)
The model tested was a Langley-built 0.015-scale SSV Orbiter model with remote independently operated left and right elevon surfaces. The objective of the test was to generate a detailed aerodynamic data base for the current Shuttle Orbiter Configuration. Special attention was directed to definition of nonlinear aerodynamic characteristics by taking data at small increments, angle of attack, angle of sideslip, and elevon position. Six-component aerodynamic force and moment and elevon position data were recorded over an angle-of-attack range from -4 deg to 45 deg, at angles of sideslip of 0 deg, + or - 2 deg, and + or - 4 deg. Additional tests were made over an angle of sideslip range from -6 deg to 8 deg at selected angles of attack. The test Mach numbers were 2.86, 3.90, and 4.60 with Reynolds number held at a constant two million per foot
Gamble mode: Resonance contact mode in atomic force microscopy
Active noise reduction has been accomplished in atomic force microscopy by applying a high frequency, low amplitude vibration to the cantilever while it is in contact with a surface. The applied excitation (>~ 200 kHz; ~ 1 nm) is acoustically coupled to the tip and dampens the resonance Q factors of the system. The applied frequency is well above the bandwidth of the acquisition system (50 kHz). We call this mode "gamble mode" or "resonance contact.
Noise reduction in atomic force microscopy: Resonance contact mode
Noise reduction has been accomplished in atomic force microscopy by applying a high frequency, low amplitude vibration to the cantilever while it is in contact with a surface. The applied excitation (>~200 kHz; ~1 nm) is acoustically coupled to the tip and dampens the resonance Q factors of the system. The applied frequency is well above the bandwidth of the acquisition system (50 kHz). We call this mode "resonance contact" mode. The nonlinear behavior of the tipāsample interaction allows the high frequency excitation to effectively broaden the frequency response of the system resonances
Calcium supplements with or without vitamin D and risk of cardiovascular events : reanalysis of the Women's Health Initiative limited access dataset and meta-analysis
Peer reviewedPublisher PD
Remotely controlled mirror of variable geometry for small angle x-ray diffraction with synchrotron radiation
A total-reflecting mirror of 120-cm length was designed and built to focus synchrotron radiation emanating from the electron-positron storage ring at the Stanford Linear Accelerator Center (SPEAR). The reflecting surface is of
unpolished float glass. The bending and tilt mechanism allows very fine control of the curvature and selectability of the critical angle for wavelengths ranging from 0.5 to 3.0 Ć
. Elliptical curvature is used to minimize aberrations. The mirror is placed asymmetrically onto the ellipse so as to achieve a tenfold demagnification of the source. The bending mechanism reduces nonelastic
deformation (flow) and minimizes strains and stresses in the glass despite its length. Special design features assure stability of the focused image. The mirror
reduces the intensity of shorter wavelength harmonics by a factor of approximately 100
A New Genus of Miniaturized and Pug-Nosed Gecko from South America (Sphaerodactylidae: Gekkota)
Sphaerodactyl geckos comprise five genera distributed across Central and South America and the Caribbean. We estimated phylogenetic relationships among sphaerodactyl genera using both separate and combined analyses of seven nuclear genes. Relationships among genera were incongruent at different loci and phylogenies were characterized by short, in some cases zero-length, internal branches and poor phylogenetic support at most nodes. We recovered a polyphyletic Coleodactylus, with Coleodactylus amazonicus being deeply divergent from the remaining Coleodactylus species sampled. The C. amazonicus lineage possessed unique codon deletions in the genes PTPN12 and RBMX while the remaining Coleodactylus species had unique codon deletions in RAG1. Topology tests could not reject a monophyletic Coleodactylus, but we show that short internal branch lengths decreased the accuracy of topology tests because there were not enough data along these short branches to support one phylogenetic hypothesis over another. Morphological data corroborated results of the molecular phylogeny, with Coleodactylus exhibiting substantial morphological heterogeneity. We identified a suite of unique craniofacial features that differentiate C. amazonicus not only from other Coleodactylus species, but also from all other geckos. We describe this novel sphaerodactyl lineage as a new genus, Chatogekko gen. nov. We present a detailed osteology of Chatogekko, characterizing osteological correlates of miniaturization that provide a framework for future studies in sphaerodactyl systematics and biology
The development and application of aerodynamic uncertainties: And flight test verification for the space shuttle orbiter
The approach used in establishing the predicted aerodynamic uncertainties and the process used in applying these uncertainties during the design of the Orbiter flight control system and the entry trajectories are presented. The flight test program that was designed to verify the stability and control derivatives with a minimum of test flights is presented and a comparison of preflight predictions with preliminary flight test results is made. It is concluded that the approach used for the Orbiter is applicable to future programs where testing is limited due to time constraints or funding
Magnetotelluric data processing: a case study
Magnetotelluric (MT) data collected simultaneously at one or more sites may be processed by a number of different methods. Such methods attempt to remove or suppress the effect of noise on the data channels. The desired results are accurate, unbiased and repeatable estimates of the impedance tensor as a function of frequency and location. In this study we perform an investigation of the analysis of an MT data set sampled at 5 s. Both single-site (SS) and remote-reference (RR) techniques are employed to estimate the impedance tensor
Z. Two biased SS estimates of Z are used to compare the performance of five coherenceĀ based acceptance criteria. It is demonstrated that the RR predicted coherence between local fields can be used for selecting data windows, and provides a necessary assessment of the reliability of a given RR estimate. It is demonstrated that the variance of an RR estimate depends strongly on the local signal-to-noise ratios (as monitored by the local predicted coherence) and depends weakly on the number of data windows, as long as coherences are above a moderate threshold. Although, for our data, an estimate of Z obtained using a remote electric field is grossly inaccurate, its associated predicted coherence is as efficient in selecting low-noise-level data windows as its counterpart obtained using a remote magnetic field. The relation between SS and RR predicted coherences, the latter estimated using both electric and magnetic fields, is investigated. A hybrid selection technique that uses a remote electric field is suggested
Making co-enrolment feasible for randomised controlled trials in paediatric intensive care.
Enrolling children into several trials could increase recruitment and lead to quicker delivery of optimal care in paediatric intensive care units (PICU). We evaluated decisions taken by clinicians and parents in PICU on co-enrolment for two large pragmatic trials: the CATCH trial (CATheters in CHildren) comparing impregnated with standard central venous catheters (CVCs) for reducing bloodstream infection in PICU and the CHIP trial comparing tight versus standard control of hyperglycaemia
- ā¦