1,295 research outputs found

    Information integrity and privacy for computerized medical patient records

    Get PDF
    Sandia National Laboratories and Oceania, Inc. entered into a Cooperative Research and Development Agreement (CRADA) in November 1993 to provide ``Information Integrity and Privacy for Computerized Medical Patient Records`` (CRADA No. SC93/01183). The main objective of the project was to develop information protection methods that are appropriate for databases of patient records in health information systems. This document describes the findings and alternative solutions that resulted from this CRADA

    P-P Total Cross Sections at VHE from Accelerator Data

    Full text link
    Comparison of P-P total cross-sections estimations at very high energies - from accelerators and cosmic rays - shows a disagreement amounting to more than 10 %, a discrepancy which is beyond statistical errors. Here we use a phenomenological model based on the Multiple-Diffraction approach to successfully describe data at accelerator energies. The predictions of the model are compared with data On the basis of regression analysis we determine confident error bands, analyzing the sensitivity of our predictions to the employed data for extrapolation. : using data at 546 and 1.8 TeV, our extrapolations for p-p total cross-sections are only compatible with the Akeno cosmic ray data, predicting a slower rise with energy than other cosmic ray results and other extrapolation methods. We discuss our results within the context of constraints in the light of future accelerator and cosmic ray experimental results.Comment: 26 pages aqnd 11 figure

    Soft X-ray harmonic comb from relativistic electron spikes

    Get PDF
    We demonstrate a new high-order harmonic generation mechanism reaching the `water window' spectral region in experiments with multi-terawatt femtosecond lasers irradiating gas jets. A few hundred harmonic orders are resolved, giving uJ/sr pulses. Harmonics are collectively emitted by an oscillating electron spike formed at the joint of the boundaries of a cavity and bow wave created by a relativistically self-focusing laser in underdense plasma. The spike sharpness and stability are explained by catastrophe theory. The mechanism is corroborated by particle-in-cell simulations

    X-ray harmonic comb from relativistic electron spikes

    Get PDF
    X-ray devices are far superior to optical ones for providing nanometre spatial and attosecond temporal resolutions. Such resolution is indispensable in biology, medicine, physics, material sciences, and their applications. A bright ultrafast coherent X-ray source is highly desirable, for example, for the diffractive imaging of individual large molecules, viruses, or cells. Here we demonstrate experimentally a new compact X-ray source involving high-order harmonics produced by a relativistic-irradiance femtosecond laser in a gas target. In our first implementation using a 9 Terawatt laser, coherent soft X-rays are emitted with a comb-like spectrum reaching the 'water window' range. The generation mechanism is robust being based on phenomena inherent in relativistic laser plasmas: self-focusing, nonlinear wave generation accompanied by electron density singularities, and collective radiation by a compact electric charge. The formation of singularities (electron density spikes) is described by the elegant mathematical catastrophe theory, which explains sudden changes in various complex systems, from physics to social sciences. The new X-ray source has advantageous scalings, as the maximum harmonic order is proportional to the cube of the laser amplitude enhanced by relativistic self-focusing in plasma. This allows straightforward extension of the coherent X-ray generation to the keV and tens of keV spectral regions. The implemented X-ray source is remarkably easily accessible: the requirements for the laser can be met in a university-scale laboratory, the gas jet is a replenishable debris-free target, and the harmonics emanate directly from the gas jet without additional devices. Our results open the way to a compact coherent ultrashort brilliant X-ray source with single shot and high-repetition rate capabilities, suitable for numerous applications and diagnostics in many research fields

    HYDRODYNAMICS AND BIO-OPTICAL ASSESSMENT OF TWO PRISTINE SUBTROPICAL ESTUARIES IN SOUTHERN BRAZIL

    Get PDF
    Measuring small-scale physical processes and how they affect the spatial patterns of sea water's optical constituents plays a key role in understanding the functioning of complex coastal ecosystems such as estuaries. The spatial variations of physical and bio-optical water properties were investigated during one spring tidal cycle in austral summer, on two transects across the channel of the Medeiros and Itaqui sub-estuaries. These sub-estuaries are a biosphere reserve, and part of the ParanaguĂĄ Estuarine System, located on the Southern Brazilian coast. Both sub-estuaries were classified as Type 1a, wellmixed with low stratification. The salinity variations are in phase with the water level, and the tidal propagation is well represented by a standing wave. The vertical velocity profiles showed little vertical shear, and the intensity of the u-component of the velocity varied semi-diurnally. The upper estuary salt transport was dominated by tidal diffusion in an unstable water column. The optical environment presented a mixed dominance of optically active substances, as indicated by the absorption coefficients of dissolved and particulate matter. The colored dissolved organic matter (CDOM) showed overall conservative behavior and was dominant in light absorption below 550 nm in the Medeiros, while nonalgal particles play the most important role in light absorption in the Itaqui in the blue absorption band. The phytoplanktonic contribution is prominent in the red domain and increases as a function of saline intrusion. However, due to the influence of freshwater discharge and the re-suspension of bottom sediments induced by physical processes, the concentrations of the optical components in the water column do not generally have any simple relationships between them

    A strategy to characterize the LISA-Pathfinder cold gas thruster system

    Get PDF
    The cold gas micro-propulsion system that will be used during the LISA-Pathfinder mission will be one of the most important component used to ensure the "free-fall" of the enclosed test masses. In this paper we present a possible strategy to characterize the effective direction and amplitude gain of each of the 6 thrusters of this system

    In-flight thermal experiments for LISA pathfinder: simulating temperature noise at the inertial sensors

    Get PDF
    Thermal Diagnostics experiments to be carried out on board LISA Pathfinder (LPF) will yield a detailed characterisation of how temperature fluctuations affect the LTP (LISA Technology Package) instrument performance, a crucial information for future space based gravitational wave detectors as the proposed eLISA. Amongst them, the study of temperature gradient fluctuations around the test masses of the Inertial Sensors will provide as well information regarding the contribution of the Brownian noise, which is expected to limit the LTP sensitivity at frequencies close to 1 mHz during some LTP experiments. In this paper we report on how these kind of Thermal Diagnostics experiments were simulated in the last LPF Simulation Campaign (November, 2013) involving all the LPF Data Analysis team and using an end-to-end simulator of the whole spacecraft. Such simulation campaign was conducted under the framework of the preparation for LPF operations

    Free-flight experiments in LISA Pathfinder

    Get PDF
    The LISA Pathfinder mission will demonstrate the technology of drag-free test masses for use as inertial references in future space-based gravitational wave detectors. To accomplish this, the Pathfinder spacecraft will perform drag-free flight about a test mass while measuring the acceleration of this primary test mass relative to a second reference test mass. Because the reference test mass is contained within the same spacecraft, it is necessary to apply forces on it to maintain its position and attitude relative to the spacecraft. These forces are a potential source of acceleration noise in the LISA Pathfinder system that are not present in the full LISA configuration. While LISA Pathfinder has been designed to meet it's primary mission requirements in the presence of this noise, recent estimates suggest that the on-orbit performance may be limited by this `suspension noise'. The drift-mode or free-flight experiments provide an opportunity to mitigate this noise source and further characterize the underlying disturbances that are of interest to the designers of LISA-like instruments. This article provides a high-level overview of these experiments and the methods under development to analyze the resulting data.Comment: 13 pages, 5 figures. Accepted to Journal Of Physics, Conference Series. Presented at 10th International LISA Symposium, May 2014, Gainesville, FL, US
    • 

    corecore