25,183 research outputs found

    Instrumentation for measuring the dynamic pressure on rotating compressor blades

    Get PDF
    To establish the capability for measurement of oscillatory pressure on rotating blades, miniature fast response semiconductor strain gage pressure transducers (2mm x 0.33mm) were mounted in several configurations on thin titanium and steel compressor blades and subjected to pressure cycles from 1 to 310 kPa during static tests and spin tests. Static test conditions included 20 C to 150 C, 0 to 3000 tensile microstrain, -1000 to +1000 bending microstrain and + or - 650G vibration. The spin test conditions included 20 C to 82 C at 0 to 90,000G. Durability was excellent. Pressure transducer sensitivity changed by only a few percent over this range of environmental conditions. Noise signal due to oscillatory acceleration normal to the diaphragm was acceptable (0.33Pa/G). Noise signal due to oscillatory strain was acceptable (0.5 Pa/microstrain) when the transducer was mounted on a 0.05mm rubber pad, with a total buildup of 0.38mm on the measure surface. Back mounting or partial recessing to eliminate buildup, increased the strain effect to 1.2 Pa/microstrain. Flush mounting within the blade to eliminate buildup reduced the strain effect, but required development of a special transducer shape. This transducer was not available in time for spin tests. Unpredictable zero drift + or - 14 kPa ruled out the use of these mounting arrangements for accurate steady-state (D.C.) measurements on rotating blades. The two best configurations fully developed and spin tested were then successfully applied in the NAS3-20606 rotating fan flutter program for quantitative measurement of oscillatory pressure amplitudes

    Turbine Blade Temperature Measurements Using Thin Film Temperature Sensors

    Get PDF
    The development of thin film temperature sensors is discussed. The technology for sputtering 2 micron thin film platinum versus platinum 10 percent rhodium thermocouples on alumina forming coatings was improved and extended to applications on actual turbine blades. Good adherence was found to depend upon achieving a proper morphology of the alumina surface. Problems of adapting fabrication procedures to turbine blades were uncovered, and improvements were recommended. Testing at 1250 K at one atmosphere pressure was then extended to a higher Mach No. (0.5) in combustor flow for 60 hours and 71 thermal cycles. The mean time to failure was 47 hours accumulated during 1 hour exposures in the combustor. Calibration drift was about 0.1 percent per hour, attributable to oxidation of the rhodium in the thin films. An increase in film thickness and application of a protective overcoat are recommended to reduce drift in actual engine testing

    Eksistensi Tindak Pidana Pelanggaran Kesusilaan di Depan Umum (Pasal 281 Kitab Undang-undang Hukum Pidana)

    Get PDF
    Tujuan dilakukannya penelitian ini adalah untuk mengetahui bagaimana cakupan Pasal 281 KUHPidana dan bagaimana eksistensi Pasal 281 KUHPidana berhadapan dengan Pasal 10 Jo Pasal Pasal 36 UU No. 44 Tahun 2008 tentang Pornografi. Dengan menggunakan metode penelitian yuridis normatif, maka dapat disimpulkan: 1. Cakupan dari tindak pidana melanggar kesusilaan di depan orang lain dalam Pasal 281 ayat 1 dan ayat 2 KUHPidana adalah dilarangnya perbuatan melanggar kesusilaan di depan umum, yaitu di tempat umum atau di tempat yang bukan tempat umum tetapi dapat dilihat/didengar dari tempat umum, atau di depan orang lain bertentangan dengan kehendaknya. Pengertian melanggar kesusilaan merupakan pelanggaran sopan santun dalam bidang seksual, di mana perbuatan melanggar kesusilaan itu pada umumnya dapat menimbulkan perasaan malu, perasaan jijik atau terangsangnya nafsu birahi orang. 2. Eksistensi Pasal 281 KUHPidana masih tetap diperlukan karena unsur melanggar kesusilaan dari Pasal 281 KUHPidana memiliki cakupann yang lebih luas dari pada perbuatan-perbuatan yang telah dirumuskan secara spesifik dalam Pasal 10 jo Pasal 36 Undang-Undang Nomor 44 Tahun 2008

    Collective Spin-Density-Wave Response Perpendicular to the Chains of the Quasi One-Dimensional Conductor (TMTSF)2PF6

    Full text link
    Microwave experiments along all three directions of the spin-density-wave model compound (TMTSF)2_2PF6_6 reveal that the pinned mode resonance is present along the aa and b′b^{\prime} axes. The collective transport is considered to be the fingerprint of the condensate. In contrast to common quasi one-dimensional models, the density wave also slides in the perpendicular b′b^{\prime} direction. The collective response is absent along the least conducting c∗c^* direction.Comment: 3 pages, 4 figure

    Measuring unsteady pressure on rotating compressor blades

    Get PDF
    Miniature semiconductor strain gage pressure transducers mounted in several arrangements were studied. Both surface mountings and recessed flush mountings were tested. Test parameters included mounting arrangement, blade material, temperature, local strain in the acceleration normal to the transducer diaphragm, centripetal acceleration, and pressure. Test results show no failures of transducers or mountings and indicate an uncertainty of unsteady pressure measurement of approximately + or - 6 percent + 0.1 kPa for a typical application. Two configurations were used on a rotating fan flutter program. Examples of transducer data and correction factors are presented

    Using ACIS on the Chandra X-ray Observatory as a particle radiation monitor II

    Full text link
    The Advanced CCD Imaging Spectrometer is an instrument on the Chandra X-ray Observatory. CCDs are vulnerable to radiation damage, particularly by soft protons in the radiation belts and solar storms. The Chandra team has implemented procedures to protect ACIS during high-radiation events including autonomous protection triggered by an on-board radiation monitor. Elevated temperatures have reduced the effectiveness of the on-board monitor. The ACIS team has developed an algorithm which uses data from the CCDs themselves to detect periods of high radiation and a flight software patch to apply this algorithm is currently active on-board the instrument. In this paper, we explore the ACIS response to particle radiation through comparisons to a number of external measures of the radiation environment. We hope to better understand the efficiency of the algorithm as a function of the flux and spectrum of the particles and the time-profile of the radiation event.Comment: 10 pages, 5 figures, to be published in Proc. SPIE 8443, "Space Telescopes and Instrumentation 2012: Ultraviolet to Gamma Ray

    Imaging X-ray spectrometer

    Get PDF
    An X-ray spectrometer for providing imaging and energy resolution of an X-ray source is described. This spectrometer is comprised of a thick silicon wafer having an embedded matrix or grid of aluminum completely through the wafer fabricated, for example, by thermal migration. The aluminum matrix defines the walls of a rectangular array of silicon X-ray detector cells or pixels. A thermally diffused aluminum electrode is also formed centrally through each of the silicon cells with biasing means being connected to the aluminum cell walls and causes lateral charge carrier depletion between the cell walls so that incident X-ray energy causes a photoelectric reaction within the silicon producing collectible charge carriers in the form of electrons which are collected and used for imaging

    Time dependent diffusion in a disordered medium with partially absorbing walls: A perturbative approach

    Full text link
    We present an analytical study of the time dependent diffusion coefficient in a dilute suspension of spheres with partially absorbing boundary condition. Following Kirkpatrick (J. Chem. Phys. 76, 4255) we obtain a perturbative expansion for the time dependent particle density using volume fraction ff of spheres as an expansion parameter. The exact single particle tt-operator for partially absorbing boundary condition is used to obtain a closed form time-dependent diffusion coefficient D(t)D(t) accurate to first order in the volume fraction ff. Short and long time limits of D(t)D(t) are checked against the known short-time results for partially or fully absorbing boundary conditions and long-time results for reflecting boundary conditions. For fully absorbing boundary condition the long time diffusion coefficient is found to be D(t)=5a2/(12fD0t)+O((D0t/a2)−2)D(t)=5 a^2/(12 f D_{0} t) +O((D_0t/a^2)^{-2}), to the first order of perturbation theory. Here ff is small but non-zero, D0D_0 the diffusion coefficient in the absence of spheres, and aa the radius of the spheres. The validity of this perturbative result is discussed
    • …
    corecore