78 research outputs found
Ferromagnetic Semiconductors: Moving Beyond (Ga,Mn)As
The recent development of MBE techniques for growth of III-V ferromagnetic
semiconductors has created materials with exceptional promise in spintronics,
i.e. electronics that exploit carrier spin polarization. Among the most
carefully studied of these materials is (Ga,Mn)As, in which meticulous
optimization of growth techniques has led to reproducible materials properties
and ferromagnetic transition temperatures well above 150 K. We review progress
in the understanding of this particular material and efforts to address
ferromagnetic semiconductors as a class. We then discuss proposals for how
these materials might find applications in spintronics. Finally, we propose
criteria that can be used to judge the potential utility of newly discovered
ferromagnetic semiconductors, and we suggest guidelines that may be helpful in
shaping the search for the ideal material.Comment: 37 pages, 4 figure
Quantization of Midisuperspace Models
We give a comprehensive review of the quantization of midisuperspace models.
Though the main focus of the paper is on quantum aspects, we also provide an
introduction to several classical points related to the definition of these
models. We cover some important issues, in particular, the use of the principle
of symmetric criticality as a very useful tool to obtain the required
Hamiltonian formulations. Two main types of reductions are discussed: those
involving metrics with two Killing vector fields and spherically symmetric
models. We also review the more general models obtained by coupling matter
fields to these systems. Throughout the paper we give separate discussions for
standard quantizations using geometrodynamical variables and those relying on
loop quantum gravity inspired methods.Comment: To appear in Living Review in Relativit
Prevention of catheter lumen occlusion with rT-PA versus heparin (Pre-CLOT): study protocol of a randomized trial [ISRCTN35253449]
BACKGROUND: Many patients with end-stage renal disease use a central venous catheter for hemodialysis access. A large majority of these catheters malfunction within one year of insertion, with up to two-thirds due to thrombosis. The optimal solution for locking the catheter between hemodialysis sessions, to decrease the risk of thrombosis and catheter malfunction, is unknown. The Prevention of Catheter Lumen Occlusion with rt-PA versus Heparin (PreCLOT) study will determine if use of weekly rt-PA, compared to regular heparin, as a catheter locking solution, will decrease the risk of catheter malfunction. METHODS/DESIGN: The study population will consist of patients requiring chronic hemodialysis thrice weekly who are dialyzed with a newly inserted permanent dual-lumen central venous catheter. Patients randomized to the treatment arm will receive rt-PA 1 mg per lumen once per week, with heparin 5,000 units per ml as a catheter locking solution for the remaining two sessions. Patients randomized to the control arm will receive heparin 5,000 units per ml as a catheter locking solution after each dialysis session. The study treatment period will be six months, with 340 patients to be recruited from 14 sites across Canada. The primary outcome will be catheter malfunction, based on mean blood flow parameters while on hemodialysis, with a secondary outcome of catheter-related bacteremia. A cost-effectiveness analysis will be undertaken to assess the cost of maintaining a catheter using rt-PA as a locking solution, compared to the use of heparin. DISCUSSION: Results from this study will determine if use of weekly rt-PA, compared to heparin, will decrease catheter malfunction, as well as assess the cost-effectiveness of these locking solutions
SnugDock: Paratope Structural Optimization during Antibody-Antigen Docking Compensates for Errors in Antibody Homology Models
High resolution structures of antibody-antigen complexes are useful for analyzing the binding interface and to make rational choices for antibody engineering. When a crystallographic structure of a complex is unavailable, the structure must be predicted using computational tools. In this work, we illustrate a novel approach, named SnugDock, to predict high-resolution antibody-antigen complex structures by simultaneously structurally optimizing the antibody-antigen rigid-body positions, the relative orientation of the antibody light and heavy chains, and the conformations of the six complementarity determining region loops. This approach is especially useful when the crystal structure of the antibody is not available, requiring allowances for inaccuracies in an antibody homology model which would otherwise frustrate rigid-backbone docking predictions. Local docking using SnugDock with the lowest-energy RosettaAntibody homology model produced more accurate predictions than standard rigid-body docking. SnugDock can be combined with ensemble docking to mimic conformer selection and induced fit resulting in increased sampling of diverse antibody conformations. The combined algorithm produced four medium (Critical Assessment of PRediction of Interactions-CAPRI rating) and seven acceptable lowest-interface-energy predictions in a test set of fifteen complexes. Structural analysis shows that diverse paratope conformations are sampled, but docked paratope backbones are not necessarily closer to the crystal structure conformations than the starting homology models. The accuracy of SnugDock predictions suggests a new genre of general docking algorithms with flexible binding interfaces targeted towards making homology models useful for further high-resolution predictions
Trace elements in hemodialysis patients: a systematic review and meta-analysis
<p>Abstract</p> <p>Background</p> <p>Hemodialysis patients are at risk for deficiency of essential trace elements and excess of toxic trace elements, both of which can affect health. We conducted a systematic review to summarize existing literature on trace element status in hemodialysis patients.</p> <p>Methods</p> <p>All studies which reported relevant data for chronic hemodialysis patients and a healthy control population were eligible, regardless of language or publication status. We included studies which measured at least one of the following elements in whole blood, serum, or plasma: antimony, arsenic, boron, cadmium, chromium, cobalt, copper, fluorine, iodine, lead, manganese, mercury, molybdenum, nickel, selenium, tellurium, thallium, vanadium, and zinc. We calculated differences between hemodialysis patients and controls using the differences in mean trace element level, divided by the pooled standard deviation.</p> <p>Results</p> <p>We identified 128 eligible studies. Available data suggested that levels of cadmium, chromium, copper, lead, and vanadium were higher and that levels of selenium, zinc and manganese were lower in hemodialysis patients, compared with controls. Pooled standard mean differences exceeded 0.8 standard deviation units (a large difference) higher than controls for cadmium, chromium, vanadium, and lower than controls for selenium, zinc, and manganese. No studies reported data on antimony, iodine, tellurium, and thallium concentrations.</p> <p>Conclusion</p> <p>Average blood levels of biologically important trace elements were substantially different in hemodialysis patients, compared with healthy controls. Since both deficiency and excess of trace elements are potentially harmful yet amenable to therapy, the hypothesis that trace element status influences the risk of adverse clinical outcomes is worthy of investigation.</p
Genetic markers associated with resistance to beta-lactam and quinolone antimicrobials in non-typhoidal Salmonella isolates from humans and animals in central Ethiopia
Abstract
Background
Beta-lactam and quinolone antimicrobials are commonly used for treatment of infections caused by non-typhoidal Salmonella (NTS) and other pathogens. Resistance to these classes of antimicrobials has increased significantly in the recent years. However, little is known on the genetic basis of resistance to these drugs in Salmonella isolates from Ethiopia.
Methods
Salmonella isolates with reduced susceptibility to beta-lactams ( n \u2009=\u200943) were tested for genes encoding for beta-lactamase enzymes, and those resistant to quinolones ( n \u2009=\u200929) for mutations in the quinolone resistance determining region (QRDR) as well as plasmid mediated quinolone resistance (PMQR) genes using PCR and sequencing.
Results
Beta-lactamase genes ( bla ) were detected in 34 (79.1%) of the isolates. The dominant bla gene was bla TEM, recovered from 33 (76.7%) of the isolates, majority being TEM-1 (24, 72.7%) followed by TEM-57, (10, 30.3%). The bla OXA-10 and bla CTX-M-15 were detected only in a single S. Concord human isolate. Double substitutions in gyr A (Ser83-Phe\u2009+\u2009Asp87-Gly) as well as par C (Thr57-Ser\u2009+\u2009Ser80-Ile) subunits of the quinolone resistance determining region (QRDR) were detected in all S. Kentucky isolates with high level resistance to both nalidixic acid and ciprofloxacin. Single amino acid substitutions, Ser83-Phe ( n \u2009=\u20094) and Ser83-Tyr ( n \u2009=\u20091) were also detected in\ua0the gyr A gene. An isolate of S . Miami susceptible to nalidixic acid but intermediately resistant to ciprofloxacin had Thr57-Ser and an additional novel mutation (Tyr83-Phe) in the par C gene. Plasmid mediated quinolone resistance (PMQR) genes investigated were not detected in any of the isolates. In some isolates with decreased susceptibility to ciprofloxacin and/or nalidixic acid, no mutations in QRDR or PMQR genes were detected. Over half of the quinolone resistant isolates in the current study 17 (58.6%) were also resistant to at least one of the beta-lactam antimicrobials.
Conclusion
Acquisition of bla TEM was the principal beta-lactamase resistance mechanism and mutations within QRDR of gyr A and par C were the primary mechanism for resistance to quinolones. Further study on extended ..
Variation in neurosurgical management of traumatic brain injury: A survey in 68 centers participating in the CENTER-TBI study
Background Neurosurgical management of traumatic brain injury (TBI) is challenging, with only low-quality evidence. We aimed to explore differences in neurosurgical strategies for TBI across Europe. Methods A survey was sent to 68 centers participating in the Collaborative European Neurotrauma Effectiveness Research in Traumatic Brain Injury (CENTER-TBI) study. The questionnaire contained 21 questions, including the decision when to operate (or not) on traumatic acute subdural hematoma (ASDH) and intracerebral hematoma (ICH), and when to perform a decompressive craniectomy (DC) in raised intracranial pressure (ICP). Results The survey was completed by 68 centers (100%). On average, 10 neurosurgeons work in each trauma center. In all centers, a neurosurgeon was available within 30 min. Forty percent of responders reported a thickness or volume threshold for evacuation of an ASDH. Most responders (78%) decide on a primary DC in evacuating an ASDH during the operation, when swelling is present. For ICH, 3% would perform an evacuation directly to prevent secondary deterioration and 66% only in case of clinical deterioration. Most respondents (91%) reported to consider a DC for refractory high ICP. The reported cut-off ICP for DC in refractory high ICP, however, differed: 60% uses 25 mmHg, 18% 30 mmHg, and 17% 20 mmHg. Treatment strategies varied substantially between regions, specifically for the threshold for ASDH surgery and DC for refractory raised ICP. Also within center variation was present: 31% reported variation within the hospital for inserting an ICP monitor and 43% for evacuating mass lesions. Conclusion Despite a homogeneous organization, considerable practice variation exists of neurosurgical strategies for TBI in Europe. These results provide an incentive for comparative effectiveness research to determine elements of effective neurosurgical care
- …