44 research outputs found

    Slewing Mirror Telescope and the Data-Acquisition System for the UFFO-Pathfinder

    Get PDF
    The Ultra-Fast Flash Observatory (UFFO) aims to detect the earliest moment of Gamma-Ray Bursts (GRBs) which is not well known, resulting into the enhancement of GRB mechanism understanding. The pathfinder mission was proposed to be a scaled-down version of UFFO, and only contains the UFFO Burst Alert & Trigger Telescope (UBAT) measuring the X-ray/gamma-ray with the wide-field of view and the Slewing Mirror Telescope (SMT) with a rapid-response for the UV/optical photons. Once the UBAT detects a GRB candidate with the position accuracy of 10 arcmin, the SMT steers the UV/optical photons from the candidate to the telescope by the fast rotatable mirror and provides the early UV/optical photons measurements with 4 arcsec accuracy. The SMT has a modified Ritchey-Chrètien telescope with the aperture size of 10 cm diameter including the rotatable mirror and the image readout by the intensified charge-coupled device. There is a key board called the UFFO Data Acquisition system (UDAQ) that manages the communication of each telescope and also of the satellite and the UFFO overall operation. This pathfinder is designed and built within the limited size and weight of  ~20 kg and the low power consumption up to  ~30 W. We will discuss the design and performance of the UFFO-pathfinder, and its integration to the Lomonosov satellite

    Slewing Mirror Telescope optics for the early observation of UV/optical photons from Gamma-Ray Bursts

    Get PDF
    We report on design, manufacture, and testing of a Slewing Mirror Telescope (SMT), the first of its kind and a part of Ultra-Fast Flash Observatory-pathfinder (UFFO-p) for space-based prompt measurement of early UV/optical light curves from Gamma-Ray Bursts (GRBs). Using a fast slewing mirror of 150 mm diameter mounted on a 2 axis gimbal stage, SMT can deliver the images of GRB optical counterparts to the intensified CCD detector within 1.5∼1.8 s over ± 35 degrees in the slewing field of view. Its Ritchey-Chrétien telescope of 100 mm diameter provides a 17 × 17 arcmin2 instantaneous field of view. Technical details of design, construction, the laboratory performance tests in space environments for this unique SMT are described in conjunction with the plan for in-orbit operation onboard the Lomonosov satellite in 2013. © 2013 Optical Society of America.This research was supported by the Korean Creative Research Initiatives (RCMST) of MEST/NRF, the Basic Science Research program of MEST/NRF (2010-0025056), the World Class University program of MEST/NRF (R32-2009-000-10130-0), the Spanish MINECO project AYA-2009-14027-C05-01, AYA-2011-29936-C05-01, AYA-2012-39727-C03-01, and AYA 2009-14000-C03-01/ESP, Taiwan's National Science Council Vanguard Program (100-2119-M-002-025) LeCosPA of National Taiwan University, Program of development of Lomonosov Moscow State University and Korean programs NRF 2012-0006632, 20100029390 and Yonsei-KASI joint research for the Frontiers of Astronomy and Space Science Program 2012Peer Reviewe

    Differential effects of Atomoxetine on executive functioning and lexical decision in Attention-Deficit/Hyperactivity Disorder and Reading Disorder

    Get PDF
    Objective: The effects of a promising pharmacological treatment for attention-deficit/hyperactivity disorder (ADHD), atomoxetine, were studied on executive functions in both ADHD and reading disorder (RD) because earlier research demonstrated an overlap in executive functioning deficits in both disorders. In addition, the effects of atomoxetine were explored on lexical decision. Methods: Sixteen children with ADHD, 20 children with ADHD + RD, 21 children with RD, and 26 normal controls were enrolled in a randomized placebo-controlled crossover study. Children were measured on visuospatial working memory, inhibition, and lexical decision on the day of randomization and following two 28-day medication periods. Results: Children with ADHD + RD showed improved visuospatial working memory performance and, to a lesser extent, improved inhibition following atomoxetine treatment compared to placebo. No differential effects of atomoxetine were found for lexical decision in comparison to placebo. In addition, no effects of atomoxetine were demonstrated in the ADHD and RD groups. Conclusion: Atomoxetine improved visuospatial working memory and to a lesser degree inhibition in children with ADHD + RD, which suggests differential developmental pathways for co-morbid ADHD + RD as compared to ADHD and RD alone

    Design and implementation of electronics and data acquisition system for Ultra-Fast Flash Observatory

    Get PDF
    The Ultra-Fast Flash Observatory (UFFO) Pathfinder for Gamma-Ray Bursts (GRBs) consists of two telescopes. The UFFO Burst Alert & Trigger Telescope (UBAT) handles the detection and localization of GRBs, and the Slewing Mirror Telescope (SMT) conducts the measurement of the UV/optical afterglow. UBAT is equipped with an X-ray detector, analog and digital signal readout electronics that detects X-rays from GRBs and determines the location. SMT is equipped with a stepping motor and the associated electronics to rotate the slewing mirror targeting the GRBs identified by UBAT. First the slewing mirror points to a GRB, then SMT obtains the optical image of the GRB using the intensified CCD and its readout electronics. The UFFO Data Acquisition system (UDAQ) is responsible for the overall function and operation of the observatory and the communication with the satellite main processor. In this paper we present the design and implementation of the electronics of UBAT and SMT as well as the architecture and implementation of UDAQ

    Development of Motorized Slewing Mirror Stage for the UFFO Project

    Get PDF
    The Ultra-Fast Flash Observatory (UFFO) is a space observatory for optical follow-ups of gamma ray bursts (GRBs), aiming to explore the first 60 seconds of GRBs optical emission. UFFO is utilized to catch early optical emissions from GRBs within few sec after trigger using a Gimbal mirror which redirects the optical path rather than slewing entire spacecraft. We have developed a 15 cm two-axis Gimbal mirror stage for the UFFO-Pathfinder which is going to be on board the Lomonosov satellite which is to be launched in 2013. The stage is designed for fast and accurate motion with given budgets of 3 kg of mass and 3 Watt of power. By employing stepping motors, the slewing mirror can rotate faster than 15 deg/sec so that objects in the UFFO coverage (60 deg × 60 deg) can be targeted in ~1 sec. The obtained targeting resolution is better 2 arcmin using a close-loop control with high precision rotary encoder. In this presentation, we will discuss details of design, manufacturing, space qualification tests, as well as performance tests

    Ultra-Fast Flash Observatory: Fast Response Space Missions for Early Time Phase of Gamma Ray Bursts

    Get PDF
    One of the unexplored domains in the study of gamma-ray bursts (GRBs) is the early time phase of the optical light curve. We have proposed Ultra-Fast Flash Observatory (UFFO) to address this question through extraordinary opportunities presented by a series of small space missions. The UFFO is equipped with a fast-response Slewing Mirror Telescope that uses a rapidly moving mirror or mirror array to redirect the optical beam rather than slewing the entire spacecraft or telescope to aim the optical instrument at the GRB position. The UFFO will probe the early optical rise of GRBs with sub-second response, for the first time, opening a completely new frontier in GRB and transient studies. Its fast response measurements of the optical emission of dozens of GRB each year will provide unique probes of the burst mechanism and test the prospect of GRB as a new standard candle, potentially opening up the z > 10 universe. We describe the current limit in early photon measurements, the aspects of early photon physics, our soon-to-be-launched UFFO-pathfinder mission, and our next planned mission, the UFFO-100

    Integrated analysis of environmental and genetic influences on cord blood DNA methylation in new-borns

    Get PDF
    Epigenetic processes, including DNA methylation (DNAm), are among the mechanisms allowing integration of genetic and environmental factors to shape cellular function. While many studies have investigated either environmental or genetic contributions to DNAm, few have assessed their integrated effects. Here we examine the relative contributions of prenatal environmental factors and genotype on DNA methylation in neonatal blood at variably methylated regions (VMRs) in 4 independent cohorts (overall n = 2365). We use Akaike’s information criterion to test which factors best explain variability of methylation in the cohort-specific VMRs: several prenatal environmental factors (E), genotypes in cis (G), or their additive (G + E) or interaction (GxE) effects. Genetic and environmental factors in combination best explain DNAm at the majority of VMRs. The CpGs best explained by either G, G + E or GxE are functionally distinct. The enrichment of genetic variants from GxE models in GWAS for complex disorders supports their importance for disease risk

    Multiplex and Quantitative Pathogen Detection with High-Resolution Capillary Electrophoresis-Based Single-Strand Conformation Polymorphism

    No full text
    Among the molecular diagnostic methods for bacteria-induced diseases, capillary electrophoresis-based single-strand conformation polymorphism (CE-SSCP) combined with 16S rRNA gene-specific PCR has enormous potential because it can separate sequence variants using a simple procedure. However, conventional CE-SSCP systems have limited resolution and cannot separate most 16S rRNA gene-specific markers into separate peaks. A high-resolution CE-SSCP system that uses a poly(ethyleneoxide)-poly(propyleneoxide)- poly(ethyleneoxide) triblock copolymer matrix was recently developed and shown to effectively separate highly similar PCR products. In this report, a protocol for the detection of 12 pathogenic bacteria is provided. Pathogen markers were amplified by PCR using universal primers and separated by CE-SSCP; each marker peak was well separated at baseline and showed a characteristic mobility, allowing the easy identification of the pathogens.11Nscopu
    corecore