1,353 research outputs found

    Processing and Transmission of Information

    Get PDF
    Contains reports on three research projects

    The Fringe Detection Laser Metrology for the GRAVITY Interferometer at the VLTI

    Full text link
    Interferometric measurements of optical path length differences of stars over large baselines can deliver extremely accurate astrometric data. The interferometer GRAVITY will simultaneously measure two objects in the field of view of the Very Large Telescope Interferometer (VLTI) of the European Southern Observatory (ESO) and determine their angular separation to a precision of 10 micro arcseconds in only 5 minutes. To perform the astrometric measurement with such a high accuracy, the differential path length through the VLTI and the instrument has to be measured (and tracked since Earth's rotation will permanently change it) by a laser metrology to an even higher level of accuracy (corresponding to 1 nm in 3 minutes). Usually, heterodyne differential path techniques are used for nanometer precision measurements, but with these methods it is difficult to track the full beam size and to follow the light path up to the primary mirror of the telescope. Here, we present the preliminary design of a differential path metrology system, developed within the GRAVITY project. It measures the instrumental differential path over the full pupil size and up to the entrance pupil location. The differential phase is measured by detecting the laser fringe pattern both on the telescopes' secondary mirrors as well as after reflection at the primary mirror. Based on our proposed design we evaluate the phase measurement accuracy based on a full budget of possible statistical and systematic errors. We show that this metrology design fulfills the high precision requirement of GRAVITY.Comment: Proc. SPIE in pres

    GRAVITY: the Calibration Unit

    Full text link
    We present in this paper the design and characterisation of a new sub-system of the VLTI 2nd generation instrument GRAVITY: the Calibration Unit. The Calibration Unit provides all functions to test and calibrate the beam combiner instrument: it creates two artificial stars on four beams, and dispose of four delay lines with an internal metrology. It also includes artificial stars for the tip-tilt and pupil guiding systems, as well as four metrology pick-up diodes, for tests and calibration of the corresponding sub-systems. The calibration unit also hosts the reference targets to align GRAVITY to the VLTI, and the safety shutters to avoid the metrology light to propagate in the VLTI-lab. We present the results of the characterisation and validtion of these differrent sub-units.Comment: 12 pages, 11 figures. Proceeding of SPIE 9146 "Optical and Infrared Interferometry IV

    The GRAVITY metrology system: modeling a metrology in optical fibers

    Full text link
    GRAVITY is the second generation VLT Interferometer (VLTI) instrument for high-precision narrow-angle astrometry and phase-referenced interferometric imaging. The laser metrology system of GRAVITY is at the heart of its astrometric mode, which must measure the distance of 2 stars with a precision of 10 micro-arcseconds. This means the metrology has to measure the optical path difference between the two beam combiners of GRAVITY to a level of 5 nm. The metrology design presents some non-common paths that have consequently to be stable at a level of 1 nm. Otherwise they would impact the performance of GRAVITY. The various tests we made in the past on the prototype give us hints on the components responsible for this error, and on their respective contribution to the total error. It is however difficult to assess their exact origin from only OPD measurements, and therefore, to propose a solution to this problem. In this paper, we present the results of a semi-empirical modeling of the fibered metrology system, relying on theoretical basis, as well as on characterisations of key components. The modeling of the metrology system regarding various effects, e.g., temperature, waveguide heating or mechanical stress, will help us to understand how the metrology behave. The goals of this modeling are to 1) model the test set-ups and reproduce the measurements (as a validation of the modeling), 2) determine the origin of the non-common path errors, and 3) propose modifications to the current metrology design to reach the required 1nm stability.Comment: 20 pages, 19 figures. Proceeding of SPIE 9146 "Optical and Infrared Interferometry IV

    Palaeohistology and palaeopathology of an Aeolosaurini (Sauropoda: Titanosauria) from Morro do Cambambe (Upper Cretaceous, Brazil)

    Get PDF
    Altres ajuts: CAISEP (Comisión de Ayudas a la Investigación de la Sociedad Española de Paleontología) project #2018-07153A recent publication of fossil bones of titanosaurs assigned to Aeolosaurini from the Morro do Cambambe site (Mato Grosso state, Brazil, Upper Cretaceous) reported anomalous growth in some of them. Here, we present osteohistological sections of elements to understand not only the microstructure and growth of such bones, but also the nature of those anomalies. The primary bone of all specimens consisted of a variation of the fibrolamellar complex, with the inner cortex being rich in woven bone with dispersed longitudinal canals, while the outer cortex was parallel-fibred with rows of longitudinal canals, interlayered by Lines of Arrested Growth (LAGs). We identified a maximum of two LAGs in the cervical rib and haemal arch, and four in the dorsal rib. The haemal arch shows an External Fundamental System (EFS) in most sections. The advanced remodelling and variation of the fibrolamellar bone in the cortex suggests that all the specimens represent individuals that reached sexual maturity. However, the haemal arch was distinct due to the wide distribution of EFS. The dorsal rib exhibited periosteal and endosteal outgrowth. Such microstructure was assigned to a reactive bone due to an intra-thoracic infection (a pneumonia, probably related to a tuberculosis), which is the first report in a non-avian dinosaur. The microstructure resembles the medullary bone recovered in dinosaurs, which suggests that further studies of medullary bone in thoracic bones should also regard the pathological cases.En una reciente publicación de los huesos fósiles de titanosaurios asignados al clado Aeolosaurini provenientes del yacimiento de Morro do Cambambe (estado de Mato Grosso, Brasil, Cretácico Superior), se reconocieron anormalidades en el crecimiento de algunos de ellos. En el presente trabajo presentamos cortes osteohistológicos de elementos para entender no sólo la microestructura y crecimiento de los mismos, sino también la naturaleza de aquellas anomalías. Entre ellos, seleccionamos una costilla cervical y una costilla dorsal media posterior, así como un arco hemal. El hueso primario de todos los especímenes comprendía una variación del complejo fibrolamelar, siendo la corteza interna rica en tejido reticular óseo con canales longitudinales dispersos, mientras que la corteza externa tenía fibras paralelas con hileras de canales longitudinales, intercaladas por líneas de crecimiento detenido. Identificamos un máximo de dos líneas de crecimiento detenido tanto en la costilla cervical como en el arco hemal, y cuatro en la costilla dorsal. El arco hemal muestra un Sistema Externo Fundamental en la mayoría de las secciones. La remodelación avanzada y la variación del hueso fibrolamelar en la corteza, se sugiere que todas los especímenes alcanzaron la madurez sexual. Sin embargo, el arco hemal fue distinto debido a la amplia distribución de Sistema Externo Fundamental. Con base en la microestructura, identificamos un semaforonte subadulto, y probablemente a un adulto. La costilla dorsal mostró una excrecencia perióstica y endosteal. Dicha microestructura se ha identificado con un hueso reactivo a una infección intratorácica (una neumonía, probablemente relacionada con una tuberculosis), que es el primer informe de un dinosaurio no aviano. La microestructura se asemeja al hueso medular recuperado en los dinosaurios, lo que sugiere que los estudios posteriores del hueso medular en los huesos torácicos también deberían considerar los casos patológicos

    Public crises, public futures

    Get PDF
    This article begins to map out a novel approach to analyzing contemporary contexts of public crisis, relationships between them and possibilities that these scenes hold out for politics. The article illustrates and analyses a small selection of examples of these kinds of contemporary scenes and calls for greater attention to be given to the conditions and consequences of different forms and practices of public and political mediation. In offering a three-fold typology to delineate differences between ‘abject’, ‘audience’ and ‘agentic’ publics the article begins to draw out how political and public futures may be seen as being bound up with how the potentialities, capacities and qualities that publics are imagined to have and resourced to perform. Public action and future publics are therefore analysed here in relation to different versions of contemporary crisis and the political concerns and publics these crises work to articulate, foreground and imaginatively and practically support
    • …
    corecore