369 research outputs found

    Structural studies and influence of the structure on the electrical and optical properties of microcrystalline silicon thin films produced by RF sputtering

    Get PDF
    Microcrystalline silicon thin films were produced by reactive magnetron sputtering on glass substrates under several different conditions (RF power and gas mixture composition). The film structure was studied by X-ray diffractometry (XRD), transmission electron microscopy (TEM) and Raman spectroscopy, allowing the determination of crystal sizes, crystallinity and mechanical strain. These parameters were evaluated by fitting a pseudo-Voigt function to the X-ray data, and by the application of the strong phonon confinement model to the Raman spectra. The degree of crystallinity and the presence of single crystals or crystal agglomerates, which was confirmed by TEM, depends on the preparation conditions, and strongly affects the optical spectra and the electrical transport properties.Fundação para a Ciência e a Tecnologia (FCT) - PRAXIS XX

    Charge Transport Properties of a Metal-free Phthalocyanine Discotic Liquid Crystal

    Full text link
    Discotic liquid crystals can self-align to form one-dimensional semiconducting wires, many tens of microns long. In this letter, we describe the preparation of semiconducting films where the stacking direction of the disc-like molecules is perpendicular to the substrate surface. We present measurements of the charge carrier mobility, applying temperature-dependent time-of-flight transient photoconductivity, space-charge limited current measurements, and field-effect mobility measurements. We provide experimental verification of the highly anisotropic nature of semiconducting films of discotic liquid crystals, with charge carrier mobilities of up to 2.8x10−3^{-3}cm2^2/Vs. These properties make discotics an interesting choice for applications such as organic photovoltaics.Comment: 5 pages, 5 figure

    Optical modulation spectroscopy of hydrogenated microcrystalline silicon

    Get PDF
    The properties of microcrystalline silicon thin films prepared by RF sputtering were investigated by optical modulation spectroscopy at room temperature and the results were correlated with Raman and conductivity measurements. For comparative purposes, a number of good quality PECVD microc-Si:H samples were also investigated. For PECVD samples the OMS signal is very weak, and only measurable for probe beam energies comparable to the gap of amorphous silicon. This indicates the absence of gap states and therefore a very high crystalline fraction, as confirmed by Raman and TEM measurements. In what concerns RF-sputtered samples, different behaviors can be distinguished: Some samples show a low OMS signal which can be attributed either to a high crystallinity (low density of gap states) or to high recombination rates. These two cases can be distinguished by electrical conductivity values and analysis of the Raman spectra. Other samples exhibit a OMS signal similar to a-Si:H and have low conductivity values, consistent with a Raman spectrum typical of a-Si:H.FCT-grant from PRAXIS XX

    Influence of copper on the electronic properties of amorphous chalcogenides

    Full text link
    We have studied the influence of alloying copper with amorphous arsenic sulfide on the electronic properties of this material. In our computer-generated models, copper is found in two-fold near-linear and four-fold square-planar configurations, which apparently correspond to Cu(I) and Cu(II) oxidation states. The number of overcoordinated atoms, both arsenic and sulfur, grows with increasing concentration of copper. Overcoordinated sulfur is found in trigonal planar configuration, and overcoordinated (four-fold) arsenic is in tetrahedral configuration. Addition of copper suppresses the localization of lone-pair electrons on chalcogen atoms, and localized states at the top of the valence band are due to Cu 3d orbitals. Evidently, these additional Cu states, which are positioned at the same energies as the states due to ([As4]-)-([S_3]+) pairs, are responsible for masking photodarkening in Cu chalcogenides

    Skin mucormycosis presenting as an erythema-nodosum-like rash in a renal transplant recipient: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Cutaneous mucormycosis is a rare entity related to kidney transplantation. It usually presents with ecthyma-like lesions and black necrotic cellulitis. We report an unusual case of primary cutaneous mucormycosis presenting as erythema-nodosum-like lesions in a woman who had received a renal transplant.</p> <p>Case presentation</p> <p>A 49-year-old woman with diabetes received a living-unrelated kidney transplant. Her clinical course was uneventful for the first six months after transplantation. She then developed multiple, painful, erythema-nodosum-like lesions on her right leg and thigh following an episode of minor trauma. Mucormycosis was diagnosed by skin biopsy. Microscopic examination also showed panniculitis. The patient was treated successfully with amphotericin B and surgical resection. To our knowledge, this is the first description of primary cutaneous mucormycosis with erythema-nodosum-like lesions and panniculitis after renal transplantation.</p> <p>Conclusion</p> <p>Cutaneous mucormycosis should be considered in the differential diagnosis when a kidney transplant recipient develops erythema-nodosum-like lesions with panniculitis.</p

    Impact of ultra-thin struts on restenosis after chronic total occlusion recanalization: Insights from the randomized PRISON IV trial

    Get PDF
    The PRISON-IV trial showed inferior outcome in patients with chronic total occlusions (CTOs) treated with the ultrathin-struts (60\u2009\u3bcm for stent diameter 643\u2009mm, 81\u3bcm &gt;3\u2009mm) hybrid-sirolimus eluting stents (SES) compared with everolimus eluting stents (EES, 81\u2009\u3bcm). The aim of this study is to investigate if the use of smaller stents ( 643\u2009mm) was responsible for the inferior outcome reported in the trial

    Intercomparison Exercise for Heavy Metals in PM10

    Get PDF
    The Joint Research Centre (JRC) has carried out an Intercomparison Exercise (IE) for the determination of heavy metals in particulate matter (PM10). The IE focussed on Lead (Pb), Arsenic (As), Nickel (Ni) and Cadmium (Cd), the heavy metals regulated by the 1st and 4th Daughter Directives for Air Pollution. Copper (Cu), Chromium (Cr) and Zinc (Zn), the elements included in the EMEP programme together with Aluminium (Al), Cobalt (Co), Iron (Fe), Manganese (Mn) and Vanadium (V) were also tested. Fourteen Laboratories, generally members of the Network of Air Quality Reference Laboratories (AQUILA), participated in the IE. The participants mainly used microwave digestion with nitric acid and hydrogen peroxide and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) or Graphite Furnace Atomic Absorption Spectrometry (GF-AAS) for analysis as recommended in the reference method (EN 14902). However, a few participants used other methods: Energy Dispersive X-ray Fluorescence (EDXRF), Atomic Emission Spectrometry (ICP-AES) and Voltammetry for analysis and vaporisation on hot plate before microwave digestion, Soxhlet extraction, high pressure or cold Hydrogen Fluoride methods for digestion. Each participant received 5 samples to be analysed: a liquid sample prepared by dilution of a Certified Reference Material (CRM), a solution of a dust CRM sample digested by the JRC13F, a sub-sample of a dust CRM that each participating laboratory had to digest and analyse, a solution prepared by JRC after digestion of an exposed filter and a pair of filters (one blank filter and one exposed filter) to be digested and analysed by each participant. For 89 % of all types of samples, the DQOs of the 1st and 4th European Directives (uncertainty of 25 % for Pb and 40 % for As, Cd and Ni) were met. All together, this is a very good score. The best results were obtained for the liquid CRM, dust CRM digested by JRC, dust CRM and filter digested by JRC with 92, 90, 96 and 93 % of DQOs being met, respectively. It was found that the DQOs were not met if the difference of acidity between test samples and participant calibration standards was high. Conversely, only 76 % of DQOs were met for the filter to be digested by each participant with (about 85 % for Cd and Ni, 73/64 % for Pb and As, the most difficult element to determine). The worst results were associated with special events: explosion in microwave oven during digestion for two participants, a wrong dilution factor used by one participant and a huge contamination in the blank filter for another participant. Among the two explosions, one of them was probably the effect of a lack of temperature control in the digestion vessel. For the other explosion, the microwave digestion and the digestion program advised by EN 14902 is to be questioned. Moreover, satisfactory results were obtained using Soxhlet extraction, high pressure method and cold Hydrogen Fluoride digestion methods which are not presented in EN 14902. The DQOs of As and Cd could not be met with EDXRF whose limit of detection was too high for these two elements and for Cd using Voltammetry which suffered a strong interference for this element. Regarding the methods of analysis, apart the points mentioned just before about EDXRF and Voltammetry, good results were observed using ICP-OES for Cd, Ni and Pb. A few discrepancies were also registered for GF-AAS and ICP-MS but they were created by the special events or acidity problem mentioned before. This shows that even though GF-AAS and ICP-MS are found suitable, the implementation by each participant may be responsible for important mistakes.JRC.H.4-Transport and air qualit

    Antibiotic consumption and antimicrobial resistance in Poland; findings and implications

    Get PDF
    Background: The problem of inappropriate use of antibiotics and the resulting growth in antimicrobial resistance (AMR) has implications for Poland and the world. The objective of this paper was to compare and contrast antibiotic resistance and antibiotic utilisation in Poland in recent years versus other European countries, including agreed quality indicators, alongside current AMR patterns and ongoing policies and initiatives in Poland to influence and improve antibiotic prescribing. Methods: A quantitative ten-year analysis (2007-2016) of the use of antibiotics based on European Centre for Disease Prevention and Control (ECDC) data combined with a literature review on AMR rates and antimicrobial stewardship initiatives. Results: The system of monitoring AMR and appropriate strategies to address AMR rates remain underdeveloped in Poland. The role of microbiological diagnostics and efforts to prevent infections is currently underestimated by physicians. Overall, Poland had one of the highest rates of total consumption of antibiotics in the analysed European countries. Total consumption of antibacterials for systemic use and relative consumption of beta-lactamase sensitive penicillins were characterized by small but statistically significant average annual increases between 2007 and 2016 (from 22.2DIDs to 23.9 DIDs and from 0.8% to 1.3%, respectively). Conclusions: The integrated activities around appropriate antibiotic prescribing in the pre- and post-graduate training of physicians and dentists seem to be particularly important, as well as changes in policies on prescribing antibiotics within ambulatory care. AMR and appropriate prescribing of antibiotics should be the focus of health policy actions in Poland
    • …
    corecore