1,332 research outputs found
Stability study and time resolution measurement of Straw Tube detectors
Straw tube detectors are single wire proportional counters that are widely
used as a tracking device. We have carried out RD with a straw tube
detector prototype. The motivation of this work is to study the stability of
the performance in terms of gain and energy resolution of the straw tube
detectors under high rate radiation. Two different methods are incorporated to
perform this study. The gain and energy resolution of the detector are studied
along with its variation with ambient temperature and pressure. X-ray from a
radioactive source is used to irradiate the detector and the same source is
also used to monitor the energy spectra simultaneously for calculation of gain.
Variation of the gain and energy resolution of the straw tube detector under
X-ray irradiation in Ar/CO gas mixture is discussed in this article. We
have also estimated the time resolution of the straw tube detectors that can be
best achieved with cosmic rays as trigger for the same gas mixture. The details
of the measurement process and the experimental results are presented in this
article
Measurement of the decay form factors in the OKA experiment
A precise measurement of the vector and axial-vector form factors difference
in the decay is presented.
About 95K events of are selected in
the OKA experiment. The result is .
Both errors are smaller than in the previous measurements.Comment: 9 pages, 8 figure
Search for Axionlike and Scalar Particles with the NA64 Experiment
We carried out a model-independent search for light scalar (s) and
pseudoscalar axionlike (a) particles that couple to two photons by using the
high-energy CERN SPS H4 electron beam. The new particles, if they exist, could
be produced through the Primakoff effect in interactions of hard bremsstrahlung
photons generated by 100 GeV electrons in the NA64 active dump with virtual
photons provided by the nuclei of the dump. The a(s) would penetrate the
downstream HCAL module, serving as shielding, and would be observed either
through their decay in the rest of the HCAL detector or
as events with large missing energy if the a(s) decays downstream of the HCAL.
This method allows for the probing the a(s) parameter space, including those
from generic axion models, inaccessible to previous experiments. No evidence of
such processes has been found from the analysis of the data corresponding to
electrons on target allowing to set new limits on the
-coupling strength for a(s) masses below 55 MeV.Comment: This publication is dedicated to the memory of our colleague Danila
Tlisov. 7 pages, 5 figures, revised version accepted for publication in Phys.
Rev. Let
Multi-layer scintillation detector for the MOON double beta decay experiment: Scintillation photon responses studied by a prototype detector MOON-1
An ensemble of multi-layer scintillators is discussed as an option of the
high-sensitivity detector Mo Observatory Of Neutrinos (MOON) for spectroscopic
measurements of neutrino-less double beta decays. A prototype detector MOON-1,
which consists of 6 layer plastic-scintillator plates, was built to study the
sensitivity of the MOON-type detector. The scintillation photon collection and
the energy resolution, which are key elements for the high-sensitivity
experiments, are found to be 1835+/-30 photo-electrons for 976 keV electrons
and sigma = 2.9+/-0.1% (dE/E = 6.8+/-0.3 % in FWHM) at the Qbb ~ 3 MeV region,
respectively. The multi-layer plastic-scintillator structure with good energy
resolution as well as good background suppression of beta-gamma rays is crucial
for the MOON-type detector to achieve the inverted hierarchy neutrino mass
sensitivity.Comment: 8 pages, 16 figures, submitted to Nucl.Instrum.Met
THE TOOLS AND MONTE CARLO WORKING GROUP Summary Report from the Les Houches 2009 Workshop on TeV Colliders
This is the summary and introduction to the proceedings contributions for the
Les Houches 2009 "Tools and Monte Carlo" working group.Comment: 144 Pages. Workshop site
http://wwwlapp.in2p3.fr/conferences/LesHouches/Houches2009/ . Conveners were
Butterworth, Maltoni, Moortgat, Richardson, Schumann and Skand
A precision measurement of direct CP violation in the decay of neutral kaons into two pions
The direct CP violation parameter Re(epsilon'/epsilon) has been measured from
the decay rates of neutral kaons into two pions using the NA48 detector at the
CERN SPS. The 2001 running period was devoted to collecting additional data
under varied conditions compared to earlier years (1997-99). The new data yield
the result: Re(epsilon'/epsilon) = (13.7 +/- 3.1) times 10^{-4}. Combining this
result with that published from the 1997, 98 and 99 data, an overall value of
Re(epsilon'/epsilon) = (14.7 +/- 2.2) times 10^{-4} is obtained from the NA48
experiment.Comment: 19 pages, 5 figures, to be published in Physics Letters
Measurement of the branching ratios of the decays Xi0 --> Sigma+ e- nubar and anti-Xi0 --> anti-Sigma+ e+ nu
From 56 days of data taking in 2002, the NA48/1 experiment observed 6316 Xi0
--> Sigma+ e- nubar candidates (with the subsequent Sigma+ --> p pi0 decay) and
555 anti-Xi0 --> anti-Sigma+ e+ nu candidates with background contamination of
215+-44 and 136+-8 events, respectively. From these samples, the branching
ratios BR(Xi0 --> Sigma+ e- nubar)= (2.51+-0.03stat+-0.09syst)E(-4) and
BR(anti-Xi0 --> anti-Sigma+ e+ nu)= (2.55+-0.14stat+-0.10syst)E(-4) were
measured allowing the determination of the CKM matrix element |Vus| =
0.209+0.023-0.028. Using the Particle Data Group average for |Vus| obtained in
semileptonic kaon decays, we measured the ratio g1/f1 = 1.20+-0.05 of the
axial-vector to vector form factors.Comment: 16 pages, 11 figures Submitted to Phys.Lett.
A new measurement of direct CP violation in two pion decays of the neutral kaon
The NA48 experiment at CERN has performed a new measurement of direct CP
violation, based on data taken in 1997 by simultaneously collecting K_L and K_S
decays into pi0pi0 and pi+pi-. The result for the CP violating parameter
Re(epsilon'/epsilon) is (18.5 +/- 4.5(stat)} +/- 5.8 (syst))x10^{-4}.Comment: 18 pages, 6 figure
- …