115 research outputs found

    Microscopic analysis of spin-momentum locking on a geometric phase metasurface

    Get PDF
    We revisit spin-orbit coupling in a plasmonic Berry metasurface composed of rotated nanoapertures, which is known to imprint a robust far-field polarization response. We present a scattering formalism that shows how that spin-momentum locking emerges from the geometry of the unit cell without requiring global rotation symmetries. We find and confirm with Mueller polarimetry measurements that spin-momentum locking is an approximate symmetry. The symmetry breakdown is ascribed to the elliptical projection of circularly polarized light into the planar surface. This breakdown is maximal when surface waves are excited, and a new set of spin-momentum locking rules is presented for this case

    MEG Upgrade Proposal

    Full text link
    We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) \mu \to e \gamma, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the 6×10146 \times 10^{-14} level. The key features of this new MEG upgrade are an increased rate capability of all detectors to enable running at the intensity frontier and improved energy, angular and timing resolutions, for both the positron and photon arms of the detector. On the positron-side a new low-mass, single volume, high granularity tracker is envisaged, in combination with a new highly segmented, fast timing counter array, to track positron from a thinner stopping target. The photon-arm, with the largest liquid xenon (LXe) detector in the world, totalling 900 l, will also be improved by increasing the granularity at the incident face, by replacing the current photomultiplier tubes (PMTs) with a larger number of smaller photosensors and optimizing the photosensor layout also on the lateral faces. A new DAQ scheme involving the implementation of a new combined readout board capable of integrating the diverse functions of digitization, trigger capability and splitter functionality into one condensed unit, is also under development. We describe here the status of the MEG experiment, the scientific merits of the upgrade and the experimental methods we plan to use.Comment: A. M. Baldini and T. Mori Spokespersons. Research proposal submitted to the Paul Scherrer Institute Research Committee for Particle Physics at the Ring Cyclotron. 131 Page

    Large Area ?-thermal Phonon TES Detector Mediated by the quasi-particle Diffusion Signal for Space Application

    Get PDF
    Low temperature detectors operated at about 0.1K have achieved excellent spectral performances in the soft X-rays, becoming appealing for new challenging measurements with space missions in Astrophysics. In order to exploit their full sensitivity, it is necessary to minimize the background signals generated by the cosmic rays, i.e., high energy protons and light nuclei, that leave sizable amounts of energy in the same spectral window of the astrophysics signals. Detectors for GeV protons and nuclei operating few millimeters from the X-ray detector at 0.1K can act as anti-coincidence to disentangle the fake signal of cosmics. Fast and large detectors are designed and fabricated. These operate by mixing the fast a-thermal phonon signal with the slow diffusive thermal ones. A greater uniformity in the response should be obtained using large shaped superconducting aluminium films that acts as phonon collectors: the quasi-particles created by high energy phonons diffuse along the film toward a small Ir TES sensor giving out to a fast rise time. Here we present the measurement of an operating prototype of a superconducting anticoincidence detector for the proposed space mission ATHENA+

    Search for anomalies in the neutrino sector with muon spectrometers and large LArTPC imaging detectors at CERN

    Full text link
    A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed in order to definitely clarify the possible existence of additional neutrino states, as pointed out by neutrino calibration source experiments, reactor and accelerator experiments and measure the corresponding oscillation parameters. The experiment is based on two identical LAr-TPCs complemented by magnetized spectrometers detecting electron and muon neutrino events at Far and Near positions, 1600 m and 300 m from the proton target, respectively. The ICARUS T600 detector, the largest LAr-TPC ever built with a size of about 600 ton of imaging mass, now running in the LNGS underground laboratory, will be moved at the CERN Far position. An additional 1/4 of the T600 detector (T150) will be constructed and located in the Near position. Two large area spectrometers will be placed downstream of the two LAr-TPC detectors to perform charge identification and muon momentum measurements from sub-GeV to several GeV energy range, greatly complementing the physics capabilities. This experiment will offer remarkable discovery potentialities, collecting a very large number of unbiased events both in the neutrino and antineutrino channels, largely adequate to definitely settle the origin of the observed neutrino-related anomalies.Comment: Contribution to the European Strategy for Particle Physics - Open Symposium Preparatory Group, Kracow 10-12 September 201

    large area superconducting tes spiderweb bolometer for multi mode cavity microwave detect

    Get PDF
    For the cosmic microwave background, the increase of the sensitivity of present superconducting TES Spiderweb Bolometers can be done coupling them to a large set of modes of the EM radiation inside the cavity. This will require a proper shaping of the horn-cavity assembly for the focal plane of the microwave telescope and the use of large area bolometers. Large area spiderweb bolometers of 8 mm diameter and a mesh size of 250 μm are fabricated in order to couple with approximately the first 20 modes of the cavity at about 140 GHz. These bolometers are fabricated with micro machining techniques from silicon wafer covered with SiO2 – Si3N4 CVD thick films, 0.3 μm and 1 μm respectively. The sensor is a Ti/Au/Ti 3 layer TES sensor with Tc tuned in the 330-380 mK and 2 mK transition width. The TES is electronically coupled to the EM gold absorber that is grown on to the spiderweb mesh in order to sense the temperature of the electron gas heated by the EM radiation. The gold absorber mesh has 5 um beam size over a Si3N4 10 μm beam size supporting mesh. The Si3N4 mesh is then fully suspended by means of DRIE back etching of the Si substrate. Here we present the first results of these large area bolometers

    Search for "anomalies" from neutrino and anti-neutrino oscillations at Delta_m^2 ~ 1eV^2 with muon spectrometers and large LAr-TPC imaging detectors

    Full text link
    This proposal describes an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam. The experiment is based on two identical LAr-TPC's followed by magnetized spectrometers, observing the electron and muon neutrino events at 1600 and 300 m from the proton target. This project will exploit the ICARUS T600, moved from LNGS to the CERN "Far" position. An additional 1/4 of the T600 detector will be constructed and located in the "Near" position. Two spectrometers will be placed downstream of the two LAr-TPC detectors to greatly complement the physics capabilities. Spectrometers will exploit a classical dipole magnetic field with iron slabs, and a new concept air-magnet, to perform charge identification and muon momentum measurements in a wide energy range over a large transverse area. In the two positions, the radial and energy spectra of the nu_e beam are practically identical. Comparing the two detectors, in absence of oscillations, all cross sections and experimental biases cancel out, and the two experimentally observed event distributions must be identical. Any difference of the event distributions at the locations of the two detectors might be attributed to the possible existence of {\nu}-oscillations, presumably due to additional neutrinos with a mixing angle sin^2(2theta_new) and a larger mass difference Delta_m^2_new. The superior quality of the LAr imaging TPC, in particular its unique electron-pi_zero discrimination allows full rejection of backgrounds and offers a lossless nu_e detection capability. The determination of the muon charge with the spectrometers allows the full separation of nu_mu from anti-nu_mu and therefore controlling systematics from muon mis-identification largely at high momenta.Comment: Experiment proposa
    corecore