183 research outputs found

    Processing Color in Astronomical Imagery

    Get PDF
    Every year, hundreds of images from telescopes on the ground and in space are released to the public, making their way into popular culture through everything from computer screens to postage stamps. These images span the entire electromagnetic spectrum from radio waves to infrared light to X-rays and gamma rays, a majority of which is undetectable to the human eye without technology. Once these data are collected, one or more specialists must process the data to create an image. Therefore, the creation of astronomical imagery involves a series of choices. How do these choices affect the comprehension of the science behind the images? What is the best way to represent data to a non-expert? Should these choices be based on aesthetics, scientific veracity, or is it possible to satisfy both? This paper reviews just one choice out of the many made by astronomical image processors: color. The choice of color is one of the most fundamental when creating an image taken with modern telescopes. We briefly explore the concept of the image as translation, particularly in the case of astronomical images from invisible portions of the electromagnetic spectrum. After placing modern astronomical imagery and photography in general in the context of its historical beginnings, we review the standards (or lack thereof) in making the basic choice of color. We discuss the possible implications for selecting one color palette over another in the context of the appropriateness of using these images as science communication products with a specific focus on how the non-expert perceives these images and how that affects their trust in science. Finally, we share new data sets that begin to look at these issues in scholarly research and discuss the need for a more robust examination of this and other related topics in the future to better understand the implications for science communications.Comment: 10 pages, 6 figures, published in Studies in Media and Communicatio

    A Universe of Sound: processing NASA data into sonifications to explore participant response

    Get PDF
    IntroductionHistorically, astronomy has prioritized visuals to present information, with scientists and communicators overlooking the critical need to communicate astrophysics with blind or low-vision audiences and provide novel channels for sighted audiences to process scientific information.MethodsThis study sonified NASA data of three astronomical objects presented as aural visualizations, then surveyed blind or low-vision and sighted individuals to elicit feedback on the experience of these pieces as it relates to enjoyment, education, and trust of the scientific data.ResultsData analyses from 3,184 sighted or blind or low-vision survey participants yielded significant self-reported learning gains and positive experiential responses.DiscussionResults showed that astrophysical data engaging multiple senses could establish additional avenues of trust, increase access, and promote awareness of accessibility in sighted and blind or low-vision communities

    Measuring femoral lesions despite CT metal artefacts: a cadaveric study

    Get PDF
    Objective Computed tomography is the modality of choice for measuring osteolysis but suffers from metal-induced artefacts obscuring periprosthetic tissues. Previous papers on metal artefact reduction (MAR) show qualitative improvements, but their algorithms have not found acceptance for clinical applications. We investigated to what extent metal artefacts interfere with the segmentation of lesions adjacent to a metal femoral implant and whether metal artefact reduction improves the manual segmentation of such lesions. Materials and methods We manually created 27 periprosthetic lesions in 10 human cadaver femora. We filled the lesions with a fibrotic interface tissue substitute. Each femur was fitted with a polished tapered cobalt-chrome prosthesis and imaged twice—once with the metal, and once with a substitute resin prosthesis inserted. Metalaffected CTs were processed using standard back-projection as well as projection interpolation (PI) MAR. Two experienced users segmented all lesions and compared segmentation accuracy. Results We achieved accurate delineation of periprosthetic lesions in the metal-free images. The presence of a metal implant led us to underestimate lesion volume and introduced geometrical errors in segmentation boundaries.MediamaticsElectrical Engineering, Mathematics and Computer Scienc

    Lipase-catalyzed Reactions at Interfaces of Two-phase Systems and Microemulsions

    Get PDF
    This work describes the influence of two polar lipids, Sn-1/3 and Sn-2 monopalmitin, on the activity of lipase in biphasic systems and in microemulsions. In previous communications, we have shown that Sn-2 monoglycerides can replace Sn-1,3 regiospecific lipases at the oil–water interface, causing a drastically reduced rate of lipolysis. We here demonstrate that even if the lipase is expelled from the interface, it can catalyze esterification of the Sn-2 monoglyceride with fatty acids in both macroscopic oil–water systems and in microemulsions, leading to formation of di- and triglycerides

    Three lateral osteotomy designs for bilateral sagittal split osteotomy: biomechanical evaluation with three-dimensional finite element analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The location of the lateral osteotomy cut during bilateral sagittal split osteotomy (BSSO) varies according to the surgeon's preference, and no consensus has been reached regarding the ideal location from the perspective of biomechanics. The purpose of this study was to evaluate the mechanical behavior of the mandible and screw-miniplate system among three lateral osteotomy designs for BSSO by using three-dimensional (3-D) finite element analysis (FEA).</p> <p>Methods</p> <p>The Trauner-Obwegeser (TO), Obwegeser (Ob), and Obwegeser-Dal Pont (OD) methods were used for BSSO. In all the FEA simulations, the distal segments were advanced by 5 mm. Each model was fixed by using miniplates. These were applied at four different locations, including along Champy's lines, to give 12 different FEA miniplate fixation methods. We examined these models under two different loads.</p> <p>Results</p> <p>The magnitudes of tooth displacement, the maximum bone stress in the vicinity of the screws, and the maximum stress on the screw-miniplate system were less in the OD method than in the Ob and TO methods at all the miniplate locations. In addition, Champy's lines models were less than those at the other miniplate locations.</p> <p>Conclusions</p> <p>The OD method allows greater mechanical stability of the mandible than the other two techniques. Further, miniplates placed along Champy's lines provide greater mechanical advantage than those placed at other locations.</p

    Planning and problem-solving training for patients with schizophrenia: a randomized controlled trial

    Get PDF
    BACKGROUND: The purpose of this study was to assess whether planning and problem-solving training is more effective in improving functional capacity in patients with schizophrenia than a training program addressing basic cognitive functions. METHODS: Eighty-nine patients with schizophrenia were randomly assigned either to a computer assisted training of planning and problem-solving or a training of basic cognition. Outcome variables included planning and problem-solving ability as well as functional capacity, which represents a proxy measure for functional outcome. RESULTS: Planning and problem-solving training improved one measure of planning and problem-solving more strongly than basic cognition training, while two other measures of planning did not show a differential effect. Participants in both groups improved over time in functional capacity. There was no differential effect of the interventions on functional capacity. CONCLUSION: A differential effect of targeting specific cognitive functions on functional capacity could not be established. Small differences on cognitive outcome variables indicate a potential for differential effects. This will have to be addressed in further research including longer treatment programs and other settings

    Backpack-mounted satellite transmitters do not affect reproductive performance in a migratory bustard

    Get PDF
    Backpack-mounted satellite transmitters (PTTs) are used extensively in the study of avian habitat use and of the movements and demography of medium- to large-bodied species, but can affect individuals’ performance and fitness. Transparent assessment of potential transmitter effects is important for both ethical accountability and confidence in, or adjustment to, life history parameter estimates. We assessed the influence of transmitters on seven reproductive parameters in Asian houbara Chlamydotis macqueenii, comparing 114 nests of 38 females carrying PTTs to 184 nests of untagged birds (non-PTT) over seven breeding seasons (2012‒2018) in Uzbekistan. There was no evidence of any influence of PTTs on: lay date (non-PTT x̅ = 91.7 Julian day ± 12.3 SD; PTT x̅ = 95.1 Julian day ± 15.7 SD); clutch size (non-PTT x̅ = 3.30 ± 0.68 SD; PTT x̅ = 3.25 ± 0.65 SD); mean egg weight at laying (non-PTT x̅ = 66.1g ± 5.4 SD; PTT x̅ = 66.4g ± 5.4 SD); nest success (non-PTT x̅ = 57.08% ± 4.3 SE; PTT x̅ = 58.24% ± 4.5 SE for nests started 2 April); egg hatchability (non-PTT x̅ = 88.3% ± 2.2 SE; PTT x̅ = 88.3% ± 2.6 SE); or chick survival to fledging from broods that had at least one surviving chick (non-PTT x̅ = 63.4% ± 4.2 SE; PTT x̅= 64.4% ± 4.7 SE). High nesting propensity (97.3% year-1 ± 1.9% SE) of tagged birds indicated minimal PTT effect on breeding probability. These findings show harness-mounted transmitters can give unbiased measures of demographic parameters of this species, and are relevant to other large-bodied, cursorial, ground-nesting birds of open habitats, particularly other bustards
    corecore