1,458 research outputs found

    Innovation in Concentrating Solar Power Technologies: A Study Drawing on Patent Data

    Get PDF
    Better understanding the innovative process of renewable energy technologies is important for tackling climate change. Though concentrating solar power is receiving growing interest, innovation studies so far have explored innovative activity in solar technologies in general, ignoring the major differences between solar photovoltaic and solar thermal technologies. This study relies on patent data to examine international innovative activity in concentrating solar power technologies. Our unique contribution, based on engineering expertise and detailed datawork, is a classification system matching solar thermal technologies to the International Patent Classification (IPC) system. To this end we suggest a narrowly defined set of IPC classes and a broader one of technologies relevant to CSP, but not exclusively so. We moreover exploit information from three international patent offices, the European, the United States and the Japanese patent office. Innovative activity in narrowly defined CSP technologies has experienced an early boom before 1980 and only recently showed some signs of more activity - a pattern closely resembling the R&D support path. R&D and innovation are concentrated in few high-tech countries - such as the U.S. or Germany. Large CSP potential is not a sufficient condition for innovation, only developed countries such as Australia with both CSP potential and adequate economic and scientific capabilities are found to be among the group of relevant innovators.Innovation, patent data, solar technologies, climate change

    Physiotherapy students\u27 perceptions and experiences of clinical prediction rules

    Get PDF
    Objectives: Clinical reasoning can be difficult to teach to pre-professional physiotherapy students due to their lack of clinical experience. It may be that tools such as clinical prediction rules (CPRs) could aid the process, but there has been little investigation into their use in physiotherapy clinical education. This study aimed to determine the perceptions and experiences of physiotherapy students regarding CPRs, and whether they are learning about CPRs on clinical placement. Design: Cross-sectional survey using a paper-based questionnaire. Participants: Final year pre-professional physiotherapy students (n=371, response rate 77%) from five universities across five states of Australia. Results: Sixty percent of respondents had not heard of CPRs, and a further 19% had not clinically used CPRs. Only 21% reported using CPRs, and of these nearly three-quarters were rarely, if ever, learning about CPRs in the clinical setting. However most of those who used CPRs (78%) believed CPRs assisted in the development of clinical reasoning skills and none (0%) was opposed to the teaching of CPRs to students. The CPRs most commonly recognised and used by students were those for determining the need for an X-ray following injuries to the ankle and foot (67%), and for identifying deep venous thrombosis (63%). Conclusions: The large majority of students in this sample knew little, if anything, about CPRs and few had learned about, experienced or practiced them on clinical placement. However, students who were aware of CPRs found them helpful for their clinical reasoning and were in favour of learning more about them

    The curvHDR Method for Gating Flow Cytometry Samples

    Get PDF
    Motivation: High-throughput flow cytometry experiments produce hundreds of large multivariate samples of cellular characteristics. These samples require specialized processing to obtain clinically meaningful measurements. A major component of this processing is a form of cell subsetting known as gating. Manual gating is time-consuming and subjective. Good automatic and semi-automatic gating algorithms are very beneficial to high-throughput flow cytometry. Results: We develop a statistical procedure, named curvHDR, for automatic and semi-automatic gating. The method combines the notions of significant high negative curvature regions and highest density regions and has the ability to adapt well to human-perceived gates. The underlying principles apply to dimension of arbitrary size, although we focus on dimensions up to three. Accompanying software, compatible with contemporary flow cytometry informatics, is developed. Availability: Software for Bioconductor within R is available

    Subtraction of test mass angular noise in the LISA Technology Package interferometer

    Full text link
    We present recent sensitivity measurements of the LISA Technology Package interferometer with articulated mirrors as test masses, actuated by piezo-electric transducers. The required longitudinal displacement resolution of 9 pm/sqrt[Hz] above 3 mHz has been demonstrated with an angular noise that corresponds to the expected in on-orbit operation. The excess noise contribution of this test mass jitter onto the sensitive displacement readout was completely subtracted by fitting the angular interferometric data streams to the longitudinal displacement measurement. Thus, this cross-coupling constitutes no limitation to the required performance of the LISA Technology Package interferometry.Comment: Applied Physics B - Lasers and Optics (2008

    Sequential Data-Adaptive Bandwidth Selection by Cross-Validation for Nonparametric Prediction

    Full text link
    We consider the problem of bandwidth selection by cross-validation from a sequential point of view in a nonparametric regression model. Having in mind that in applications one often aims at estimation, prediction and change detection simultaneously, we investigate that approach for sequential kernel smoothers in order to base these tasks on a single statistic. We provide uniform weak laws of large numbers and weak consistency results for the cross-validated bandwidth. Extensions to weakly dependent error terms are discussed as well. The errors may be {\alpha}-mixing or L2-near epoch dependent, which guarantees that the uniform convergence of the cross validation sum and the consistency of the cross-validated bandwidth hold true for a large class of time series. The method is illustrated by analyzing photovoltaic data.Comment: 26 page

    Rethinking clinical trials of transcranial direct current stimulation: Participant and assessor blinding is inadequate at intensities of 2mA

    Get PDF
    Copyright @ 2012 The Authors. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and 85 reproduction in any medium, provided the original author and source are credited. The article was made available through the Brunel University Open Access Publishing Fund.Background: Many double-blind clinical trials of transcranial direct current stimulation (tDCS) use stimulus intensities of 2 mA despite the fact that blinding has not been formally validated under these conditions. The aim of this study was to test the assumption that sham 2 mA tDCS achieves effective blinding. Methods: A randomised double blind crossover trial. 100 tDCS-naïve healthy volunteers were incorrectly advised that they there were taking part in a trial of tDCS on word memory. Participants attended for two separate sessions. In each session, they completed a word memory task, then received active or sham tDCS (order randomised) at 2 mA stimulation intensity for 20 minutes and then repeated the word memory task. They then judged whether they believed they had received active stimulation and rated their confidence in that judgement. The blinded assessor noted when red marks were observed at the electrode sites post-stimulation. Results: tDCS at 2 mA was not effectively blinded. That is, participants correctly judged the stimulation condition greater than would be expected to by chance at both the first session (kappa level of agreement (κ) 0.28, 95% confidence interval (CI) 0.09 to 0.47 p = 0.005) and the second session (κ = 0.77, 95%CI 0.64 to 0.90), p = <0.001) indicating inadequate participant blinding. Redness at the reference electrode site was noticeable following active stimulation more than sham stimulation (session one, κ = 0.512, 95%CI 0.363 to 0.66, p<0.001; session two, κ = 0.677, 95%CI 0.534 to 0.82) indicating inadequate assessor blinding. Conclusions: Our results suggest that blinding in studies using tDCS at intensities of 2 mA is inadequate. Positive results from such studies should be interpreted with caution.GLM is supported by the National Health & Medical Research Council of Australia ID 571090

    The translation, validity and reliability of the German version of the Fremantle Back Awareness Questionnaire

    Get PDF
    Background: The Fremantle Back Awareness Questionnaire (FreBAQ) claims to assess disrupted self-perception of the back. The aim of this study was to develop a German version of the Fre-BAQ (FreBAQ-G) and assess its test-retest reliability, its known-groups validity and its convergent validity with another purported measure of back perception. Methods: The FreBaQ-G was translated following international guidelines for the transcultural adaptation of questionnaires. Thirty-five patients with non-specific CLBP and 48 healthy participants were recruited. Assessor one administered the FreBAQ-G to each patient with CLBP on two separate days to quantify intra-observer reliability. Assessor two administered the FreBaQ-G to each patient on day 1. The scores were compared to those obtained by assessor one on day 1 to assess inter-observer reliability. Known-groups validity was quantified by comparing the FreBAQ-G score between patients and healthy controls. To assess convergent validity, patient\u27s FreBAQ-G scores were correlated to their two-point discrimination (TPD) scores. Results: Intra- and Inter-observer reliability were both moderate with ICC3.1 = 0.88 (95%CI: 0.77 to 0.94) and 0.89 (95%CI: 0.79 to 0.94), respectively. Intra- and inter-observer limits of agreement (LoA) were 6.2 (95%CI: 5.0±8.1) and 6.0 (4.8±7.8), respectively. The adjusted mean difference between patients and controls was 5.4 (95%CI: 3.0 to 7.8, p\u3c0.01). Patient\u27s FreBAQ-G scores were not associated with TPD thresholds (Pearson\u27s r = -0.05, p = 0.79). Conclusions: The FreBAQ-G demonstrated a degree of reliability and known-groups validity. Interpretation of patient level data should be performed with caution because the LoA were substantial. It did not demonstrate convergent validity against TPD. Floor effects of some items of the FreBAQ-G may have influenced the validity and reliability results. The clinimetric properties of the FreBAQ-G require further investigation as a simple measure of disrupted self-perception of the back before firm recommendations on its use can be made
    corecore