79 research outputs found

    Analysis of Indoor Radon Distribution Within a Room By Means of Computational Fluid Dynamics (CFD) Simulation

    Get PDF
    Radon gas is recognized by international organizations such as the United States Environmental Protection Agency (US-EPA) as the main contributor of radiation environmental to which human beings are exposed. Therefore, the evaluation of indoor radon concentration is a matter of public interest. The emanation and the income of the gas inside a room will generate a negative impact on the quality of the air when the place is not properly ventilated. Understanding how this gas will be distributed inside the room will allow to predict the spatial and temporal variations of radon levels and identify these parameters will provide important information that researchers can be used for calculate radiation dose exposure. Consequently, this studies can prevent a health risk for the people that live or work within the room. Currently, several researchers use the technique called Computational Fluid Dynamics (CFD) to simulate the distribution of gas radon, making use of the various commercial programs that exist in the market. In this work, three simulations were developed in rooms that have a similar geometry but different dimensions, in order to observe how the gas is distributed inside a closed space and to analyze how this distribution varies when the volume of the place is increased. The results show that as the volume of the site increases the radon is mitigated more rapidly and therefore has lower levels of concentration of this gas, as long as the level of radon emanation is kept constant

    Analysis and characterization of neutron scattering of a Linear Accelerator (LINAC) on medical applications.

    Get PDF
    In several theoretical and experimental studies, the topic of the undesirable generation of photoneutrons in rooms where a linear accelerator (LINAC) operates has been discussed. When energies above 10 MeV are used to produce X-rays and give radiotherapy treatment to patients resulting in additional radiation to patients. Accordingly, an analysis and characterization of the neutron scattering distribution on different zones in a treatment room contributes to evaluate the radiological health risk to patients, technical and other workers involved in treatment. For the evaluation, a device developed at the PAD-IFUNAM formed by a CR-39 detector enclosed by two 3mm thick acrylic plates was employed. To avoid environmental contamination, the CR-39 and the acrylics plates are enclosed in a round plastic box. Sixteen of these devices were settled in different places inside the treatment room, where a linear accelerator is used. The results show a significant concentration of neutron scattering in areas near the head of irradiation. The recommendation will be to evaluate the neutron scattering concentration in all rooms that’s operates a LINAC in order to verify the radiological health risk and to mitigate the neutron scattering when concentration levels are to high like those in our case, in order to avoid unnecessary exposition to patients and personnel in general

    The Indoor Radon Concentration within the Tunnels of the Cholula Pyramid Through a Nuclear Tracks Methodology

    Get PDF
    Global organizations, including the World Health Organization (WHO), the Environmental Protection Agency of the United States (US-EPA) and the European Atomic Energy Community (EURATOM) recognize that radon gas as one of the main contributors to environmental radiation exposure for humans. Accordingly, a study and analysis of the indoors radon concentrate in the Cholula Pyramid contributes to understand the Radon dynamic inside of the Pyramid tunnels and to evaluate the radiological health risk to visitors, archaeologists, anthropologists and persons who spend extended periods inside the Pyramid. In this paper, the radon measurements along the Pyramid tunnels are presented. The Nuclear Track Methodology (NTM) was chosen for the measurements, using a close end-cup device developed at the Dosimetry Application Project (DAP) of the Physics Institute UNAM, following very well established protocols for the chemical etching and reading with the Counting Analysis Digital Imaging System (CADIS). The Cholula Pyramid consists of eight stages of constructions, each built in different periods of time. Cholula Pyramid is recognized as the pyramid with the largest base in the World, with 400 meters per side and 65 meters high. The tunnels of the pyramid were built in 1931 by architect Ignacio Marquina, with the aim of exploring and studying the structure. The results show an important indoor radon concentration in the measured tunnels, several times higher than levels recommended by United States Environmental Protection Agency (US-EPA). The recommendation will be to mitigate the radon concentration levels, in order to avoid unnecessary exposition to the people

    Optimization of the Position of the CR-39 Polycarbonate Sheet Inside the Solid State Track Detector “Measuring Device” Through Computational Fluid Dynamics Technique

    Get PDF
    The “measuring device” is one of the most reliable, efficient and economic indoor radon dosimeters that exist. This device was developed by the Proyecto de Aplicaciones de la Dosimetría (PAD) at the Physics Institute of UNAM (IF-UNAM) and consists of a transparent rigid plastic cup, a CR-39 polycarbonate sheet and a standard size metal clip that is used to hold the polycarbonate in the center of the cup. The cup is wrapped and covered with a low-density polyurethane protector in order to prevent the detector from being irradiated by ionizing particles found in the environment. In this work, an analysis was carried out that allowed to understand how the radon concentration on the polycarbonate sheet varies when its height is changed with respect to the base of the plastic cup, in order to understand what position increase the probability of interaction between radon and the surface of the detector. For the development of this work, four computational simulations were performed with the technique called Computational Fluid Dynamics (CFD). The results shows that as the CR-39 is positioned more closed to the base of the cup, the probability of interaction of the radon and the detector increase. Based on these results it is concluded that, when there is a limit in the time in which a measuring device can be placed in the zone where it is desired to quantify indoor radon, it is recommended to collocated the CR-39 at 1 cm with respect to the base of the cup

    Analysis of the Energy Deposit in the Air by Radiation of Alpha Particles Emitted by the Water of a Spring Through the Geant4 Software

    Get PDF
    This work presents the development of an analysis of the potential radiological risk generated by alpha particles emitted by radon-222, content in a spring water, for the population that usually swims in the place and for the people who live near this spring. This spring is located in the state of Puebla. Several measurements in the water of this place by researchers from IF-UNAM showed that it contains an average radon concentration level of 70 Bq/m3. To evaluate this radiological risk, it has been developed a computational simulation to know the area and the height where the alpha particles deposit their energy to the medium, as well as the amount of energy that they transfer. This simulation was developed in the Geant4 scientific software and the calculations were executed in the supercomputer of the Laboratorio Nacional de Supercomputo del Sureste de Mexico of the BUAP. The results show that the energy deposit occurs within the superficial limits of the spring, between 7 and 8 meters high. This deposited is not only by the alpha particles, but also by the secondary particles that are generated by the interaction of alpha particles with the environment. Based on these results, it is confirmed that there is no radiological risk by energy deposit by alpha particles for the people

    Hallazgos Clínicos y Anatomopatológicos en Aves White Leghorn Ocasionados por Ornithobacterium rhinotracheale y Escherichia coli en Condiciones Controladas

    Get PDF
    This study aimed to determine the clinical signs and pathological findings caused for Ornithobacterium rhinotracheale and Escherichia coli in White Leghorn layers under controlled conditions. A total of 80 replacement hens of five weeks were selected. Before starting the experiment, microbiological tests were conducted in 16 chicks to verify if they were exposed to pathogens. The remaining 64 chicks were distributed in four equal groups (n=16). On day 1 of the experiment G1 and G2 were inoculated via intranasal with 0.6 x 107 UFC/ml of O. rhinotracheale and G3 and G4 (negative control) received brain heart infusion broth. Forty eight hours later, G2 and G3 were inoculated via intranasal with 0.6 x 107 UFC of E. coli. Four chicks per group were slaughtered on days 3, 7, 14, and 21 after inoculation and samples were collected from paranasal sinuses, trachea, lung, air sacs and liver for optic and transmission electron microscopy. In addition, histochemical techniques (PAS and Weigert) were used to show the presence of mucus and fibrin in respiratory organs. The study allowed evidencing a delay in the growth rate and presence of lymphoid tissue associated to mucosa in chicks inoculated with O. rhinotracheale and E. coli.El presente estudio tuvo como objetivo determinar los signos clínicos y los hallazgos anatomopatológicos ocasionados por Ornithobacterium rhinotracheale y Escherichia coli en aves de postura bajo condiciones controladas. Se seleccionaron 80 gallinas ponedoras White Leghorn de cinco semanas de edad. Previo al experimento, se realizaron análisis microbiológicos en 16 aves para chequear si habían sido expuestas a agentes microbianos. Las restantes 64 pollitas fueron distribuidas en cuatro grupos de 16 aves. G1 y G2 fueron inoculadas con 0.6 x 107 UFC/ml de O. rhinotracheale en el día 1 del experimento, y G3 y G4 (control negativo) recibieron caldo cerebro corazón por vía intranasal. En las 48 h siguientes, G2 y G3 fueron inoculadas con 0.6 x 107 UFC de E. coli por vía intranasal. Cuatro pollitas por grupo fueron sacrificadas a los 3, 7, 14 y 21 días de la inoculación y se tomaron muestras de exudados de senos paranasales, tráquea, pulmón, sacos aéreos e hígado para microscopía óptica y electrónica de transmisión. Además se utilizaron técnicas histoquímicas (PAS y Weigert) para demostrar la presencia de mucus y fibrina en órganos respiratorios. El estudio permitió evidenciar un retardo del crecimiento y se demostró alteraciones del tejido linfoide asociado a mucosas en las pollitas inoculadas con O. rhinotracheale y E. coli

    TESLA Technical Design Report Part III: Physics at an e+e- Linear Collider

    Full text link
    The TESLA Technical Design Report Part III: Physics at an e+e- Linear ColliderComment: 192 pages, 131 figures. Some figures have reduced quality. Full quality figures can be obtained from http://tesla.desy.de/tdr. Editors - R.-D. Heuer, D.J. Miller, F. Richard, P.M. Zerwa

    Patients' preferences for subcutaneous trastuzumab versus conventional intravenous infusion for the adjuvant treatment of HER2-positive early breast cancer: final analysis of 488 patients in the international, randomized, two-cohort PrefHer study

    Get PDF
    PrefHer revealed compelling and consistent patient preference for subcutaneous (s.c.) trastuzumab, regardless of delivery by single-use injection device or hand-held syringe. s.c. trastuzumab was well-tolerated and safety data, including immunogenicity, were consistent with previous reports. No new safety signals were identified compared with the known intravenous trastuzumab profile in early breast cance

    MEGARA, the new intermediate-resolution optical IFU and MOS for GTC: getting ready for the telescope

    Get PDF
    MEGARA (Multi-Espectrógrafo en GTC de Alta Resolución para Astronomía) is an optical Integral-Field Unit (IFU) and Multi-Object Spectrograph (MOS) designed for the GTC 10.4m telescope in La Palma that is being built by a Consortium led by UCM (Spain) that also includes INAOE (Mexico), IAA-CSIC (Spain), and UPM (Spain). The instrument is currently finishing AIV and will be sent to GTC on November 2016 for its on-sky commissioning on April 2017. The MEGARA IFU fiber bundle (LCB) covers 12.5x11.3 arcsec2 with a spaxel size of 0.62 arcsec while the MEGARA MOS mode allows observing up to 92 objects in a region of 3.5x3.5 arcmin2 around the IFU. The IFU and MOS modes of MEGARA will provide identical intermediate-to-high spectral resolutions (RFWHM~6,000, 12,000 and 18,700, respectively for the low-, mid- and high-resolution Volume Phase Holographic gratings) in the range 3700-9800ÅÅ. An x-y mechanism placed at the pseudo-slit position allows (1) exchanging between the two observing modes and (2) focusing the spectrograph for each VPH setup. The spectrograph is a collimator-camera system that has a total of 11 VPHs simultaneously available (out of the 18 VPHs designed and being built) that are placed in the pupil by means of a wheel and an insertion mechanism. The custom-made cryostat hosts a 4kx4k 15-μm CCD. The unique characteristics of MEGARA in terms of throughput and versatility and the unsurpassed collecting are of GTC make of this instrument the most efficient tool to date to analyze astrophysical objects at intermediate spectral resolutions. In these proceedings we present a summary of the instrument characteristics and the results from the AIV phase. All subsystems have been successfully integrated and the system-level AIV phase is progressing as expected

    Choice of the initial antiretroviral treatment for HIV-positive individuals in the era of integrase inhibitors

    Get PDF
    BACKGROUND: We aimed to describe the most frequently prescribed initial antiretroviral therapy (ART) regimens in recent years in HIV-positive persons in the Cohort of the Spanish HIV/AIDS Research Network (CoRIS) and to investigate factors associated with the choice of each regimen. METHODS: We analyzed initial ART regimens prescribed in adults participating in CoRIS from 2014 to 2017. Only regimens prescribed in >5% of patients were considered. We used multivariable multinomial regression to estimate Relative Risk Ratios (RRRs) for the association between sociodemographic and clinical characteristics and the choice of the initial regimen. RESULTS: Among 2874 participants, abacavir(ABC)/lamivudine(3TC)/dolutegavir(DTG) was the most frequently prescribed regimen (32.1%), followed by tenofovir disoproxil fumarate (TDF)/emtricitabine (FTC)/elvitegravir(EVG)/cobicistat(COBI) (14.9%), TDF/FTC/rilpivirine (RPV) (14.0%), tenofovir alafenamide (TAF)/FTC/EVG/COBI (13.7%), TDF/FTC+DTG (10.0%), TDF/FTC+darunavir/ritonavir or darunavir/cobicistat (bDRV) (9.8%) and TDF/FTC+raltegravir (RAL) (5.6%). Compared with ABC/3TC/DTG, starting TDF/FTC/RPV was less likely in patients with CD4100.000 copies/mL. TDF/FTC+DTG was more frequent in those with CD4100.000 copies/mL. TDF/FTC+RAL and TDF/FTC+bDRV were also more frequent among patients with CD4<200 cells//muL and with transmission categories other than men who have sex with men. Compared with ABC/3TC/DTG, the prescription of other initial ART regimens decreased from 2014-2015 to 2016-2017 with the exception of TDF/FTC+DTG. Differences in the choice of the initial ART regimen were observed by hospitals' location. CONCLUSIONS: The choice of initial ART regimens is consistent with Spanish guidelines' recommendations, but is also clearly influenced by physician's perception based on patient's clinical and sociodemographic variables and by the prescribing hospital location
    corecore