200 research outputs found

    Heavy Meson Production at COSY - 11

    Get PDF
    The COSY-11 collaboration has measured the total cross section for the pp --> pp eta-prime and pp --> pp eta reactions in the excess energy range from Q = 1.5 MeV to Q = 23.6 MeV and from Q = 0.5 MeV to Q = 5.4 MeV, respectively. Measurements have been performed with the total luminosity of 73 nb^(-1) for the pp --> pp eta reaction and 1360 nb^(-1) for the pp --> pp eta-prime one. Recent results are presented and discussed.Comment: Invited talk at 4th International Conference on Physics at Storage Rings (STORI 99), Bloomington, Indiana, USA, September 12-16, 199

    Near-Threshold eta Meson Production in Proton-Proton Collisions

    Full text link
    The production of eta mesons has been measured in the proton-proton interaction close to the reaction threshold using the COSY-11 internal facility at the cooler synchrotron COSY. Total cross sections were determined for eight different excess energies in the range from 0.5 MeV to 5.4 MeV. The energy dependence of the total cross section is well described by the available phase-space volume weighted by FSI factors for the proton-proton and proton-eta pairs.Comment: 9 pages, 1 table, 5 figure

    Absolute response of Fuji imaging plate detectors to picosecond-electron bunches

    Get PDF
    The characterization of the absolute number of electrons generated by laser wakefield acceleration often relies on absolutely calibrated FUJI imaging plates (IP), although their validity in the regime of extreme peak currents is untested. Here, we present an extensive study on the dependence of the sensitivity of BAS-SR and BAS-MS IP to picosecond electron bunches of varying charge of up to 60 pC, performed at the electron accelerator ELBE, making use of about three orders of magnitude of higher peak intensity than in prior studies. We demonstrate that the response of the IPs shows no saturation effect and that the BAS-SR IP sensitivity of 0.0081 photostimulated luminescence per electron number confirms surprisingly well data from previous works. However, the use of the identical readout system and handling procedures turned out to be crucial and, if unnoticed, may be an important error source

    Absolute response of Fuji imaging plate detectors to picosecond-electron bunches

    Get PDF
    The characterization of the absolute number of electrons generated by laser wakefield acceleration often relies on absolutely calibrated FUJI imaging plates (IP), although their validity in the regime of extreme peak currents is untested. Here, we present an extensive study on the dependence of the sensitivity of BAS-SR and BAS-MS IP to picosecond electron bunches of varying charge of up to 60 pC, performed at the electron accelerator ELBE, making use of about three orders of magnitude of higher peak intensity than in prior studies. We demonstrate that the response of the IPs shows no saturation effect and that the BAS-SR IP sensitivity of 0.0081 photostimulated luminescence per electron number confirms surprisingly well data from previous works. However, the use of the identical readout system and handling procedures turned out to be crucial and, if unnoticed, may be an important error source

    Bleeding and first-year mortality following hip fracture surgery and preoperative use of low-dose acetylsalicylic acid: an observational cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hip fracture is associated with high mortality. Cardiovascular disease and other comorbidities requiring long-term anticoagulant medication are common in these mostly elderly patients. The objective of our observational cohort study of patients undergoing surgery for hip fracture was to study the association between preoperative use of low-dose acetylsalicylic acid (LdAA) and intraoperative blood loss, blood transfusion and first-year all-cause mortality.</p> <p>Methods</p> <p>An observational cohort study was conducted on patients with hip fracture (cervical requiring hemiarthroplasty or pertrochanteric or subtrochanteric requiring internal fixation) participating in a randomized trial that found lack of efficacy of a compression bandage in reducing postoperative bleeding. The participants were 255 patients (≥50 years) of whom 118 (46%) were using LdAA (defined as ≤320 mg daily) preoperatively. Bleeding variables in patients with and without LdAA treatment at time of fracture were measured and blood transfusions given were compared using logistic regression. The association between first-year mortality and preoperative use of LdAA was analyzed with Cox regression adjusting for age, sex, type of fracture, baseline renal dysfunction and baseline cardiovascular and/or cerebrovascular disease.</p> <p>Results</p> <p>Blood transfusions were given postoperatively to 74 (62.7%) LdAA-treated and 76 (54%) non-treated patients; the adjusted odds ratio was 1.8 (95% CI 1.04 to 3.3). First-year mortality was significantly higher in LdAA-treated patients; the adjusted hazard ratio (HR) was 2.35 (95% CI 1.23 to 4.49). The mortality was also higher with baseline cardiovascular and/or cerebrovascular disease, adjusted HR 2.78 (95% CI 1.31 to 5.88). Patients treated with LdAA preoperatively were significantly more likely to suffer thromboembolic events (5.7% vs. 0.7%, P = 0.03).</p> <p>Conclusions</p> <p>In patients with hip fracture (cervical treated with hemiarthroplasty or pertrochanteric or subtrochanteric treated with internal fixation) preoperative use of low-dose acetylsalicylic acid was associated with significantly increased need for postoperative blood transfusions and significantly higher all-cause mortality during one year after surgery.</p

    Resting and Post Bronchial Challenge Testing Carbon Dioxide Partial Pressure in Individuals with and without Asthma

    Get PDF
    Objective: There is conflicting evidence about resting carbon dioxide levels in asthmatic individuals. We wanted to determine if transcutaneously measured carbon dioxide levels prior and during bronchial provocation testing differ according to asthma status reflecting dysfunctional breathing. Methods: We investigated active firefighters and policemen by means of a validated questionnaire on respiratory symptoms, spirometry, bronchial challenge testing with methacholine (MCT) and measurement of transcutaneous blood carbon dioxide partial pressure (PtcCO 2) at rest prior performing spirometry, one minute and five minutes after termination of MCT. A respiratory physician blinded to the PtcCO2 results assigned a diagnosis of asthma after reviewing the available study data and the files of the workers medical screening program. Results: The study sample consisted of 128 male and 10 female individuals. Fifteen individuals (11%) had physiciandiagnosed asthma. There was no clinically important difference in median PtcCO 2 at rest, one and five minutes after recovery from MCT in asthmatics compared to non-asthmatics (35.6 vs 35.7 mmHg, p = 0.466; 34.7 vs 33.4 mmHg, p = 0.245 and 37.4 vs 36.4 mmHg, p = 0.732). The median drop in PtcCO2 during MCT and the increase after MCT was lower in asthmatics compared to non-asthmatics (0.1 vs 3.2 mmHg, p = 0.014 and 1.9 vs 2.9 mmHg, p = 0.025). Conclusions: PtcCO2 levels at rest prior and during recovery after MCT do not differ in individuals with or without physicia

    Total Cross Section of the Reaction pp \to pK^+\Lambda Close to Threshold

    Full text link
    The energy dependence of the total cross section for the pp \to pK^+\Lambda reaction was measured in the threshold region covering the excess energy range up to 7MeV. Existing model calculations describe the slope of the measured cross sections well, but are too low by a factor of two to three in rate. The data were used for a precise determination of the beam momentum of the COSY-synchrotron.Comment: 11 pages, 5 figure
    • …
    corecore