257 research outputs found
Domain switching energies: Mechanical versus electrical loading in La-doped bismuth ferrite-lead titanate
The mechanical stress-induced domain switching and energy dissipation in morphotropic phase boundary (1 - x)(Bi(1-y)La(y))FeO(3)-xPbTiO(3) during uniaxial compressive loading have been investigated at three different temperatures. The strain obtained was found to decrease with increasing lanthanum content, although a sharp increase in strain was observed for compositions doped with 7.5 and 10 at. % La. Increased domain switching was found in compositions with decreased tetragonality. This is discussed in terms of the competing influences of the amount of domain switching and the spontaneous strain on the macroscopic behavior under external fields. Comparison of the mechanically and electrically dissipated energy showed significant differences, discussed in terms of the different microscopic interactions of electric field and stress.open10
Overdiagnosis and overtreatment of breast cancer: Is overdiagnosis an issue for radiologists?
Overdiagnosis is diagnosis of cancers that would not present within the life of the patient and is one of the downsides of screening. This applies to low-grade ductal carcinoma in situ and some small grade 1 invasive cancers. Radiologists are responsible for cancer diagnosis, but at the time of diagnosis they cannot determine whether a particular low-grade diagnosis is one to which the definition of overdiagnosis applies. Overdiagnosis is likely to be driven by technological developments, including digital mammography, computer-aided detection and improved biopsy techniques. It is also driven by the patient's fear that cancer will be missed and the doctor's fear of litigation. It is therefore an issue of importance for radiologists, presenting them with difficult fine-tuned decisions in every assessment clinic that are ultimately counted later by those who evaluate their screening
Conductive Polymer Combined Silk Fiber Bundle for Bioelectrical Signal Recording
Electrode materials for recording biomedical signals, such as electrocardiography (ECG), electroencephalography (EEG) and evoked potentials data, are expected to be soft, hydrophilic and electroconductive to minimize the stress imposed on living tissue, especially during long-term monitoring. We have developed and characterized string-shaped electrodes made from conductive polymer with silk fiber bundles (thread), which offer a new biocompatible stress free interface with living tissue in both wet and dry conditions
In vitro selectivity, in vivo biodistribution and tumour uptake of annexin V radiolabelled with a positron emitting radioisotope
The availability of a noninvasive method to detect and quantify apoptosis in tumours will enable tumour response to several cancer therapies to be assessed. We have synthesised two radiotracers, annexin V and the N-succinimidyl-3-iodobenzoic acid (SIB) derivative of annexin V, labelled with radio-iodine (124I and 125I) and provided proof of the concept by assessing specific binding and biodistribution of these probes to apoptotic cells and tumours. We have also assessed the tumour uptake of [124I]annexin V in a mouse model of apoptosis. RIF-1 cells induced to undergo apoptosis in vitro showed a drug concentration-dependent increased binding of [125I]annexin V and [125I]SIB–annexin V. In the same model system, there was an increase in terminal deoxynucleotidyl transferase-mediated nick end labelling (TUNEL)-positive cells and a decrease in clonogenic survival. Radiotracer binding was completely inhibited by preincubation with unlabelled annexin V. In RIF-1 tumour-bearing mice, rapid distribution of [125I]SIB–annexin V-derived radioactivity to kidneys was observed and the radiotracer accumulated in urine. The binding of [125I]SIB–annexin V to RIF-1 tumours increased by 2.3-fold at 48 h after a single intraperitoneal injection of 5-fluorouracil (165 mg kg−1 body weight), compared to a 4.4-fold increase in TUNEL-positive cells measured by immunostaining. Positron emission tomography images with both radiotracers demonstrated intense localisation in the kidneys and bladder. Unlike [124I]SIB–annexin V, [124I]annexin V also showed localisation in the thyroid region presumably due to deiodination of the radiolabel. [124I]SIB–annexin V is an attractive candidate for in vivo imaging of apoptosis by PET
Automatic Nonlinear Filtering and Segmentation for Breast Ultrasound Images
Breast cancer is one of the leading causes of cancer death among women worldwide. The proposed approach comprises three steps as follows. Firstly, the image is preprocessed to remove speckle noise while preserving important features of the image. Three methods are investigated, i.e., Frost Filter, Detail Preserving Anisotropic Diffusion, and Probabilistic Patch-Based Filter. Secondly, Normalized Cut or Quick Shift is used to provide an initial segmentation map for breast lesions. Thirdly, a postprocessing step is proposed to select the correct region from a set of candidate regions. This approach is implemented on a dataset containing 20 B-mode ultrasound images, acquired from UDIAT Diagnostic Center of Sabadell, Spain. The overall system performance is determined against the ground truth images. The best system performance is achieved through the following combinations: Frost Filter with Quick Shift, Detail Preserving Anisotropic Diffusion with Normalized Cut and Probabilistic Patch-Based with Normalized Cut
MRI compared to conventional diagnostic work-up in the detection and evaluation of invasive lobular carcinoma of the breast: a review of existing literature
Item does not contain fulltextPURPOSE: The clinical diagnosis and management of invasive lobular carcinoma (ILC) of the breast presents difficulties. Magnetic resonance imaging (MRI) has been proposed as the imaging modality of choice for the evaluation of ILC. Small studies addressing different aspects of MRI in ILC have been presented but no large series to date. To address the usefulness of MRI in the work-up of ILC, we performed a review of the currently published literature. MATERIALS AND METHODS: We performed a literature search using the query "lobular AND (MRI OR MR OR MRT OR magnetic)" in the Cochrane library, PubMed and scholar.google.com, to retrieve all articles that dealt with the use of MRI in patients with ILC. We addressed sensitivity, morphologic appearance, correlation with pathology, detection of additional lesions, and impact of MRI on surgery as different endpoints. Whenever possible we performed meta-analysis of the pooled data. RESULTS: Sensitivity is 93.3% and equal to overall sensitivity of MRI for malignancy in the breast. Morphologic appearance is highly heterogeneous and probably heavily influenced by interreader variability. Correlation with pathology ranges from 0.81 to 0.97; overestimation of lesion size occurs but is rare. In 32% of patients, additional ipsilateral lesions are detected and in 7% contralateral lesions are only detected by MRI. Consequently, MRI induces change in surgical management in 28.3% of cases. CONCLUSION: This analysis indicates MRI to be valuable in the work-up of ILC. It provides additional knowledge that cannot be obtained by conventional imaging modalities which can be helpful in patient treatment
Impact of screening for breast cancer in high-risk women on health-related quality of life
The effectiveness of intensive surveillance in women at high risk for breast cancer due to a familial or genetic predisposition is uncertain and is currently being evaluated in a Dutch magnetic resonance imaging (MRI) screening (MRISC) study, in which annual imaging consists of mammography and MRI. Unfavourable side effects on health-related quality of life may arise from this screening process. We examined the short-term effects of screening for breast cancer in high-risk women on generic health-related quality of life and distress. A total of 519 participants in the MRISC study were asked to complete generic health-status questionnaires (SF-36, EQ-5D) as well as additional questionnaires for distress and items relating to breast cancer screening, at three different time points around screening. The study population showed significantly better generic health-related quality of life scores compared to age-/sex-adjusted reference scores from the general population. Neither generic health-related quality of life scores nor distress scores among the study sample (n = 334) showed significant changes over time. The impact of the screening process on generic health status did not differ between risk categories. Relatively more women reported mammography as quite to very painful (30.1%) compared to MRI. Anxiety was experienced by 37% of the women undergoing MRI. We conclude that screening for breast cancer in high-risk women does not have an unfavourable impact on short-term generic health-related quality of life and general distress. In this study, high-risk women who opted for regular breast cancer screening had a better health status than women from the general population
Is zero underestimation feasible? Extended Vacuum-assisted breast biopsy in solid lesions – a blind study
This is an Open Access article distributed under the terms of the Creative Commons Attribution Licens
Prospective screening study of 0.5 Tesla dedicated magnetic resonance imaging for the detection of breast cancer in young, high-risk women
BACKGROUND: Evidence-based screening guidelines are needed for women under 40 with a family history of breast cancer, a BRCA1 or BRCA2 mutation, or other risk factors. An accurate assessment of breast cancer risk is required to balance the benefits and risks of surveillance, yet published studies have used narrow risk assessment schemata for enrollment. Breast density limits the sensitivity of film-screen mammography but is not thought to pose a limitation to MRI, however the utility of MRI surveillance has not been specifically examined before in women with dense breasts. Also, all MRI surveillance studies yet reported have used high strength magnets that may not be practical for dedicated imaging in many breast centers. Medium strength 0.5 Tesla MRI may provide an alternative economic option for surveillance. METHODS: We conducted a prospective, nonrandomized pilot study of 30 women age 25–49 years with dense breasts evaluating the addition of 0.5 Tesla MRI to conventional screening. All participants had a high quantitative breast cancer risk, defined as ≥ 3.5% over the next 5 years per the Gail or BRCAPRO models, and/or a known BRCA1 or BRCA2 germline mutation. RESULTS: The average age at enrollment was 41.4 years and the average 5-year risk was 4.8%. Twenty-two subjects had BIRADS category 1 or 2 breast MRIs (negative or probably benign), whereas no category 4 or 5 MRIs (possibly or probably malignant) were observed. Eight subjects had BIRADS 3 results, identifying lesions that were "probably benign", yet prompting further evaluation. One of these subjects was diagnosed with a stage T1aN0M0 invasive ductal carcinoma, and later determined to be a BRCA1 mutation carrier. CONCLUSION: Using medium-strength MRI we were able to detect 1 early breast tumor that was mammographically undetectable among 30 young high-risk women with dense breasts. These results support the concept that breast MRI can enhance surveillance for young high-risk women with dense breasts, and further suggest that a medium-strength instrument is sufficient for this application. For the first time, we demonstrate the use of quantitative breast cancer risk assessment via a combination of the Gail and BRCAPRO models for enrollment in a screening trial
- …