624 research outputs found

    Therapeutic Targeting of STAT3 (Signal Transducers and Activators of Transcription 3) Pathway Inhibits Experimental Autoimmune Uveitis

    Get PDF
    Mice with targeted deletion of STAT3 in CD4+ T-cells do not develop experimental autoimmune uveitis (EAU) or experimental autoimmune encephalomyelitis (EAE), in part, because they cannot generate pathogenic Th17 cells. In this study, we have used ORLL-NIH001, a small synthetic compound that inhibits transcriptional activity of STAT3, to ameliorate EAU, an animal model of human posterior uveitis. We show that by attenuating inflammatory properties of uveitogenic lymphocytes, ORLL-NIH001 inhibited the recruitment of inflammatory cells into the retina during EAU and prevented the massive destruction of the neuroretina caused by pro-inflammatory cytokines produced by the autoreactive lymphocytes. Decrease in disease severity observed in ORLL-NIH001-treated mice, correlated with the down-regulation of α4β1 and α4β7 integrin activation and marked reduction of CCR6 and CXCR3 expression, providing a mechanism by which ORLL-NIH001 mitigated EAU. Furthermore, we show that ORLL-NIH001 inhibited the expansion of human Th17 cells, underscoring its potential as a drug for the treatment of human uveitis. Two synthetic molecules that target the Th17 lineage transcription factors, RORγt and RORα, have recently been suggested as potential drugs for inhibiting Th17 development and treating CNS inflammatory diseases. However, inhibiting STAT3 pathways completely blocks Th17 development, as well as, prevents trafficking of inflammatory cells into CNS tissues, making STAT3 a more attractive therapeutic target. Thus, use of ORLL-NIH001 to target the STAT3 transcription factor, thereby antagonizing Th17 expansion and expression of proteins that mediate T cell chemotaxis, provides an attractive new therapeutic approach for treatment of posterior uveitis and other CNS autoimmune diseases mediated by Th17 cells

    Speaker- versus listener-oriented disfluency: A re-examination of arguments and assumptions from autism spectrum disorder

    Get PDF
    We re-evaluate conclusions about disfluency production in high-functioning forms of autism spectrum disorder (HFA). Previous studies examined individuals with HFA to address a theoretical question regarding speaker- and listener-oriented disfluencies. Individuals with HFA tend to be self-centric and have poor pragmatic language skills, and should be less likely to produce listener-oriented disfluency. However, previous studies did not account for individual differences variables that affect disfluency. We show that both matched and unmatched controls produce fewer repairs than individuals with HFA. For silent pauses, there was no difference between matched controls and HFA, but both groups produced more than unmatched controls. These results identify limitations in prior research and shed light on the relationship between autism spectrum disorders and disfluent speech

    Arthroscopy vs. MRI for a detailed assessment of cartilage disease in osteoarthritis: diagnostic value of MRI in clinical practice

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In patients with osteoarthritis, a detailed assessment of degenerative cartilage disease is important to recommend adequate treatment. Using a representative sample of patients, this study investigated whether MRI is reliable for a detailed cartilage assessment in patients with osteoarthritis of the knee.</p> <p>Methods</p> <p>In a cross sectional-study as a part of a retrospective case-control study, 36 patients (mean age 53.1 years) with clinically relevant osteoarthritis received standardized MRI (sag. T1-TSE, cor. STIR-TSE, trans. fat-suppressed PD-TSE, sag. fat-suppressed PD-TSE, Siemens Magnetom Avanto syngo MR B 15) on a 1.5 Tesla unit. Within a maximum of three months later, arthroscopic grading of the articular surfaces was performed. MRI grading by two blinded observers was compared to arthroscopic findings. Diagnostic values as well as intra- and inter-observer values were assessed.</p> <p>Results</p> <p>Inter-observer agreement between readers 1 and 2 was good (kappa = 0.65) within all compartments. Intra-observer agreement comparing MRI grading to arthroscopic grading showed moderate to good values for readers 1 and 2 (kappa = 0.50 and 0.62, respectively), the poorest being within the patellofemoral joint (kappa = 0.32 and 0.52). Sensitivities were relatively low at all grades, particularly for grade 3 cartilage lesions. A tendency to underestimate cartilage disorders on MR images was not noticed.</p> <p>Conclusions</p> <p>According to our results, the use of MRI for precise grading of the cartilage in osteoarthritis is limited. Even if the practical benefit of MRI in pretreatment diagnostics is unequivocal, a diagnostic arthroscopy is of outstanding value when a grading of the cartilage is crucial for a definitive decision regarding therapeutic options in patients with osteoarthritis.</p

    Assessment of examiner leniency and stringency ('hawk-dove effect') in the MRCP(UK) clinical examination (PACES) using multi-facet Rasch modelling

    Get PDF
    BACKGROUND: A potential problem of clinical examinations is known as the hawk-dove problem, some examiners being more stringent and requiring a higher performance than other examiners who are more lenient. Although the problem has been known qualitatively for at least a century, we know of no previous statistical estimation of the size of the effect in a large-scale, high-stakes examination. Here we use FACETS to carry out a multi-facet Rasch modelling of the paired judgements made by examiners in the clinical examination (PACES) of MRCP(UK), where identical candidates were assessed in identical situations, allowing calculation of examiner stringency. METHODS: Data were analysed from the first nine diets of PACES, which were taken between June 2001 and March 2004 by 10,145 candidates. Each candidate was assessed by two examiners on each of seven separate tasks. with the candidates assessed by a total of 1,259 examiners, resulting in a total of 142,030 marks. Examiner demographics were described in terms of age, sex, ethnicity, and total number of candidates examined. RESULTS: FACETS suggested that about 87% of main effect variance was due to candidate differences, 1% due to station differences, and 12% due to differences between examiners in leniency-stringency. Multiple regression suggested that greater examiner stringency was associated with greater examiner experience and being from an ethnic minority. Male and female examiners showed no overall difference in stringency. Examination scores were adjusted for examiner stringency and it was shown that for the present pass mark, the outcome for 95.9% of candidates would be unchanged using adjusted marks, whereas 2.6% of candidates would have passed, even though they had failed on the basis of raw marks, and 1.5% of candidates would have failed, despite passing on the basis of raw marks. CONCLUSION: Examiners do differ in their leniency or stringency, and the effect can be estimated using Rasch modelling. The reasons for differences are not clear, but there are some demographic correlates, and the effects appear to be reliable across time. Account can be taken of differences, either by adjusting marks or, perhaps more effectively and more justifiably, by pairing high and low stringency examiners, so that raw marks can be used in the determination of pass and fail

    The effect of cartilage and bone density of mushroom-shaped, photooxidized, osteochondral transplants: an experimental study on graft performance in sheep using transplants originating from different species

    Get PDF
    BACKGROUND: Differences in overall performance of osteochondral photooxidized grafts were studied in accordance of their species origin and a new, more rigorous cleansing procedure using alcohol during preparation. METHODS: Photooxidized mushroom-shaped grafts of bovine, ovine, human and equine origin were implanted in the femoral condyles of 32 sheep (condyles: n = 64). No viable chondrocytes were present at the time of implantation. Grafts were evaluated at 6 months using plastic embedded sections of non-decalcified bone and cartilage specimens. Graft incorporation, the formation of cyst-like lesions at the base of the cartilage junction as well as cartilage morphology was studied qualitatively, semi-quantitatively using a score system and quantitatively by performing histomorphometrical measurements of percentage of bone and fibrous tissue of the original defects. For statistical analysis a factorial analysis of variance (ANOVA- test) was applied. RESULTS: Differences of graft performance were found according to species origin and cleansing process during graft preparation. According to the score system cartilage surface integrity was best for equine grafts, as well as dislocation or mechanical stability. The equine grafts showed the highest percentage for bone and lowest for fibrous tissue, resp. cystic lesions. The new, more rigorous cleansing process decreased cartilage persistence and overall graft performance. CONCLUSION: Performance of grafts from equine origin was better compared to bovine, ovine and human grafts. The exact reason for this difference was not proven in the current study, but could be related to differences in density of cartilage and subchondral bone between species

    A randomized, controlled, prospective trial to evaluate the haemostatic effect of Lyostypt versus Surgicel in arterial bypass anastomosis: "COBBANA" trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The development of suture hole bleeding at peripheral arterial bypass anastomoses using PTFE graft prostheses is a common problem in peripheral vascular surgery. Traditionally the problem is managed by compression with surgical swabs and reversal heparin or by using several haemostatic device (e.g. different forms of collagen, oxidized cellulose, gelatine sponge, ethylcyanoacrylate glue or fibrin) with various success. Preclinical data suggest that the haemostatic effect of collagen is stronger than that of oxidized cellulose, but no direct clinical comparison of their hemostatic performance has been published so far.</p> <p>Design</p> <p>This randomized, controlled, prospective trial evaluates the haemostatic effect of Lyostypt versus Surgicel in arterial bypass anastomosis. 28 patients undergoing an elective peripheral vascular reconstruction due to peripheral vascular disease will be included. Suture hole bleeding occurring at the arterial bypass anastomosis using a PTFE prostheses will be stopped by the application of Lyostypt and/or Surgicel. The proximal anastomoses will be randomized intraoperatively. The patients will be allocated into 4 different treatment groups. Group1 Lyostypt distal/Surgicel proximal; Group 2: Lyostypt proximal/Surgicel distal; Group 3: Surgicel distal and proximal; Group 4: Lyostypt distal and proximal. Primary endpoint of the study is time to haemostasis. Secondary endpoints are the number of intraoperatively used haemostatic devices, postoperative mortality within 30 days as well as the intraoperative efficacy rating of the two devices evaluated by the surgeon. As a safety secondary parameter, the local and general complication occurring till 30 ± 10 days postoperatively will also be analysed. After hospital discharge the investigator will examine the enrolled patients again at 30 days after surgery.</p> <p>Discussion</p> <p>The COBBANA trial aims to assess, whether the haemostatic effect of Lyostypt is superior to Surgicel in suture hole bleedings of arterial bypass anastomoses.</p> <p>Trial registration</p> <p>NCT00837954</p
    • …
    corecore