541 research outputs found

    A multi-stage model for dielectric barrier discharge in atmospheric pressure air

    Get PDF
    In this paper, a multi-stage numerical methodology for the description of the Dielectric Barrier Discharge physics in air is discussed. The behavior of the heavy species is computed using drift-diffusion equations. Electrons are taken into account by solving a non-linear formulation of electrostatics. The physical effects of the steamer discharges are modelled by means of a simplified 0D approach. The model also includes a semi-implicit 0D model for the assessment of the elementary chemical processes occurring in air. The developed methodology is employed for the simulation of a volumetric Dielectric Barrier Discharge reactor. The obtained species number density and surface charge deposition rates and are shown and discussed

    Real Time Power Control in a High Voltage Power Supply for Dielectric Barrier Discharge Reactors: Implementation Strategy and Load Thermal Analysis

    Get PDF
    Atmospheric-pressure plasma treatments for industrial and biomedical applications are often performed using Dielectric Barrier Discharge reactors. Dedicated power supplies are needed to provide the high voltage frequency waveforms to operate these nonlinear and time-dependent loads. Moreover, there is a growing technical need for reliable and reproducible treatments, which require the discharge parameters to be actively controlled. In this work, we illustrate a low-cost power supply topology based on a push-pull converter. We perform experimental measurements on two different reactor topologies (surface and volumetric), showing that open loop operation of the power supply leads to a temperature and average power increase over time. The temperature increases by Delta T-vol similar to 120 degrees C and Delta T-sup similar to 70 degrees C, while the power increases by Delta P-vol similar to 78% and Delta P-sup similar to 60% for the volumetric (40 s) and superficial reactors (120 s), respectively. We discuss how these changes are often unwanted in practical applications. A simplified circuital model of the power supply-reactor system is used to infer the physical relation between the observed reactor thermal behavior and its electrical characteristics. We then show a control strategy for the power supply voltage to ensure constant average power operation of the device based on real-time power measurements on the high voltage side of the power supply and an empirical expression relating the delivered power to the power supply output voltage. These are performed with an Arduino Due microcontroller unit, also used to control the power supply. In a controlled operation the measured power stays within 5% of the reference value for both configurations, reducing the temperature increments to Delta T-vol similar to 80 degrees C and Delta T-sup similar to 44 degrees C, respectively. The obtained results show that the proposed novel control strategy is capable of following the transient temperature behavior, achieving a constant average power operation and subsequently limiting the reactor thermal stress

    Assessment of AC Corrosion Probability in Buried Pipelines with a FEM-Assisted Stochastic Approach

    Get PDF
    In this paper, a stochastic approach is combined with field theory and circuit methods to study how the geometrical and electrical properties of holidays (defects or pores in the insulating coating) in a metallic pipeline influence the probability of exceeding the current density limit for corrosion. Three-dimensional FEM simulations are conducted to assess the influence of the shape and electrical resistivity of the pore on the computed spread resistance value. The obtained results are then used to evaluate the probability of exceeding a given current density value for different sizes of pore and soil resistivities. Finally, a case of 50 Hz interference along a pipeline-transmission line routing is examined. The probabilistic approach presented in this paper allows the pipeline sections more subjected to the induced AC corrosion risk to be identified to be used as an auxiliary tool for adopting preventive protection countermeasures. Lastly, unlike most papers devoted to assessing electromagnetic interference on pipelines, the present work uses a probabilistic rather than a deterministic approach, representing its main novelty aspect

    Airborne pollen in Alpine sites

    Get PDF
    Airborne pollen is usually monitored at urban centers, where most people live, to provide information on types and amount of allergenic pollen. Thus, very few aerobiological data are available for remote, mountainous sites. This study aims to characterize the biological quality of the air in an alpine valley in Trentino (North Italy), a region highly interested by the presence of tourists (e.g., 9.3 million overnight stays registered during June - September 2021). Materials and Methods An aerobiological study was carried out during late spring and summer in 2020 and 2021 in Val di Rabbi, an alpine valley located in the Trentino sector of Stelvio National Park. Gravitational Sigma2 samplers were selected for the survey, for their reliability and efficiency (VDI_2119 2013) and easy handling at remote sites (Gottardini et al. 2021), and installed at 2 m above ground level in 5 sites located at altitudes ranging from 700 to 2000 m a.s.l. Sampling surfaces, treated with an adhesive medium, were analyzed by optical microscopy (OM; 400×; Leitz Diaplan) for pollen identification and count (weekly samples); the average daily sedimentation rate (P cm–2 d–1 ) was calculated for the June-August period. In 2021, an active Hirst-type sampler was concurrently installed in one of the five sites (daily samples). Samples were processed and analyzed following conventional techniques and standardized protocols (UNI EN 16868:2019). Results and Discussion In the two study periods, the number of identified pollen taxa ranged from 25 at the highest elevation site (2000 m a.s.l.) to 39 at the lowest elevation (700 m a.s.l.). The proportion of arboreal pollen slightly decreased with the altitude, from 51% to 42%. The three most abundant pollen taxa were pine (Pinus), grasses (Poaceae) and neetle (Urticaceae), even if in different proportion at each site. The only grass and nettle allergenic pollen represented on average the 52% of the total pollen. The pollen season peak for grasses showed a delay of about 4 days every 100 m of elevation (Figure 1). 47 pollen taxa were identified, by active sampling, 10 more than by the passive one. The most abundant pollen taxa detected by active sampling were pine, grasses, and nettle, as for passive sampling, with the last two representing even the 71% of the total. The pollen season peak for grasses was on 22nd June, coherently with the passive sampling results at the same site. Conclusions Our mountain aerobiological study reveals the presence of allergenic pollen even at high altitude, with noteworthy shifts in the pollen season. The surveyed data can be further exploited for studying the plant biodiversity in remote areas, as well as to provide useful information for allergic tourist and hikers. Moreover, passive sampling proved to be a feasible solution for aerobiological studies in remote or orographically complex areas, typically excluded in routine air quality monitoring. References Gottardini et al. (2021). AAQR, Vol. 21, https://doi.org/10.4209/aaqr.210010 VDI_2119 (2013). Ambient air measurements. Sampling of atmospheric particles > 2.5 μm on an acceptor surface using the Sigma-2 passive sampler. Characterization by optical microscopy and calculation of number settling rate and mass concentration. ICS: 13.040.01. Beuth Verlag, Berlin. Germany. Acknowledgements The study was partially financed by Provincia Autonoma di Trento (IT). We are grateful to Mattia Precazzini and Gabriele Canella for the support in field work, and to Maria Cristina Viola for the microscope pollen analysis

    FLARE: A Framework for the Finite Element Simulation of Electromagnetic Interference on Buried Metallic Pipelines

    Get PDF
    The functionality of buried metallic pipelines can be compromised by the electrical lines that share the same right-of-way. Given the considerable size of shared corridors, computer simulation is an important tool for performing risk assessment and mitigation design. In this work, we introduce an open-source computational framework for the analysis of electromagnetic interference on large earth-return structures. The developed framework is based on FLARE-an efficient finite element solver developed by the authors in MATLAB((R)). FLARE includes solvers for problems involving static electric and magnetic fields, and DC and time-harmonic AC currents. Quasi-magnetostatic transient problems can be studied through time-marching or-for linear problems-with an efficient inverse-Laplace approach. In this work, we succinctly describe the optimization of time-critical operations in FLARE, as well as the implementation of a transient solver with automatic time-stepping. We validate the numerical results obtained with FLARE via a comparison with the commercial software COMSOL Multiphysics((R)). We then use the validated time-marching analysis results to test the accuracy and efficiency of three numerical inverse-Laplace algorithms. The test problem considered is the assessment of the inductive coupling between a 500 kV transmission line and a metallic pipeline buried in the soil

    Heterogeneous and anisotropic dynamics of a 2D gel

    Full text link
    We report X-ray Photon Correlation Spectroscopy (XPCS) results on a bidimensional (2D) gel formed by a Langmuir monolayer of gold nanoparticles. The system allows an experimental determination of the fourth order time correlation function which is compared to the usual second order correlation functions and to the mechanical response measured on macroscopic scale. The observed dynamics is anisotropic, heterogeneous and super-diffusive on the nanoscale. Different time scales, associated with fast heterogeneous dynamics inside 2D cages and slower motion of larger parts of the film, can be identified from the correlation functions

    Micro Finite Element models of the vertebral body: Validation of local displacement predictions

    Get PDF
    The estimation of local and structural mechanical properties of bones with micro Finite Element (microFE) models based on Micro Computed Tomography images depends on the quality bone geometry is captured, reconstructed and modelled. The aim of this study was to validate microFE models predictions of local displacements for vertebral bodies and to evaluate the effect of the elastic tissue modulus on model’s predictions of axial forces. Four porcine thoracic vertebrae were axially compressed in situ, in a step-wise fashion and scanned at approximately 39μm resolution in preloaded and loaded conditions. A global digital volume correlation (DVC) approach was used to compute the full-field displacements. Homogeneous, isotropic and linear elastic microFE models were generated with boundary conditions assigned from the interpolated displacement field measured from the DVC. Measured and predicted local displacements were compared for the cortical and trabecular compartments in the middle of the specimens. Models were run with two different tissue moduli defined from microindentation data (12.0GPa) and a back-calculation procedure (4.6GPa). The predicted sum of axial reaction forces was compared to the experimental values for each specimen. MicroFE models predicted more than 87% of the variation in the displacement measurements (R2 = 0.87–0.99). However, model predictions of axial forces were largely overestimated (80–369%) for a tissue modulus of 12.0GPa, whereas differences in the range 10–80% were found for a back-calculated tissue modulus. The specimen with the lowest density showed a large number of elements strained beyond yield and the highest predictive errors. This study shows that the simplest microFE models can accurately predict quantitatively the local displacements and qualitatively the strain distribution within the vertebral body, independently from the considered bone types

    Reliability and inter-observer agreement of dermoscopic diagnosis of melanoma and melanocytic naevi

    Get PDF
    The aim of this study was to analyse the reliability and the inter- observer agreement of dermoscopy in the diagnosis of melanocytic skin lesions. Nine dermatologists, with a different training experience and who routinely used dermoscopy in different hospitals in Italy, evaluated clinical and dermoscopy photographs of 15 melanocytic lesions (four invasive melanomas, four histologically common naevi, and seven naevi with histological atypia). A further series of dermoscopic photographs of 40 melanocytic lesions was evaluated to quantify inter-observer concordance in recognizing dermoscopic criteria. Compared to the true (histological) diagnosis, clinical diagnosis (categories: melanoma, common naevus, atypical naevus) was correct in 40% of cases (range, 27-53%). The percentage raised to 55% (40-73%) by the use of dermoscopy, with an average improvement of 15.6%. Concerning melanoma, clinical diagnosis resulted in a sensitivity of 41.9%, specificity of 77.8%, positive predictive value (PPV) of 36.1%, negative predictive value (NPV) of 81.8%. By using dermoscopy, an improvement of diagnostic performance was found (sensitivity 75%, specificity 88.8%, VPP 71.0%, VPN 90.7%). The inter-observer agreement in melanoma diagnosis, by using dermoscopy, was similar to that obtained by clinical examination (k statistics = 0.54 and 0.52, respectively). Concerning dermoscopic criteria, the best agreement among observers was found for pseudopods, a dermoscopic parameter related to the radial growth phase of melanoma. We conclude that dermoscopy is an useful tool for a non-invasive diagnosis of melanocytic skin lesions, improving the diagnostic performance compared to clinical examination

    Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional Levels

    Get PDF
    Accurate measurement of local strain in heterogeneous and anisotropic bone tissue is fundamental to understand the pathophysiology of musculoskeletal diseases, to evaluate the effect of interventions from preclinical studies, and to optimize the design and delivery of biomaterials. Digital volume correlation (DVC) can be used to measure the three-dimensional displacement and strain fields from micro-computed tomography (μCT) images of loaded specimens. However, this approach is affected by the quality of the input images, by the morphology and density of the tissue under investigation, by the correlation scheme, and by the operational parameters used in the computation. Therefore, for each application, the precision of the method should be evaluated. In this paper, we present the results collected from datasets analyzed in previous studies as well as new data from a recent experimental campaign for characterizing the relationship between the precision of two different DVC approaches and the spatial resolution of the outputs. Different bone structures scanned with laboratory source μCT or synchrotron light μCT (SRμCT) were processed in zero-strain tests to evaluate the precision of the DVC methods as a function of the subvolume size that ranged from 8 to 2,500 µm. The results confirmed that for every microstructure the precision of DVC improves for larger subvolume size, following power laws. However, for the first time, large differences in the precision of both local and global DVC approaches have been highlighted when SRμCT or in vivo μCT images were used instead of conventional ex vivo μCT. These findings suggest that in situ mechanical testing protocols applied in SRμCT facilities should be optimized to allow DVC analyses of localized strain measurements. Moreover, for in vivo μCT applications, DVC analyses should be performed only with relatively course spatial resolution for achieving a reasonable precision of the method. In conclusion, we have extensively shown that the precision of both tested DVC approaches is affected by different bone structures, different input image resolution, and different subvolume sizes. Before each specific application, DVC users should always apply a similar approach to find the best compromise between precision and spatial resolution of the measurements
    • …
    corecore