640 research outputs found

    Paired Associative Stimulation drives the emergence of motor resonance

    Get PDF
    Abstract Background Associative plasticity, the neurophysiological bases of Hebbian learning, has been implied in the formation of the association between sensory and motor representations of actions in the Mirror Neuron System; however, such inductor role still needs empirical support. Objective/hypothesis We have assessed whether Paired Associative Stimulation (PAS), known to activate Hebbian associative plasticity, can induce the formation of atypical (absent in normal conditions), visuo-motor associations, reshaping motor resonance. Methods Healthy participants underwent a novel PAS protocol (mirror-PAS, m-PAS), during which they were exposed to repeated pairings of transcranial magnetic stimulation (TMS) applied over the right primary motor cortex (M1), time-locked with the view of index-finger movements of the right (ipsilateral) hand. In a first experiment, the inter-stimulus interval (ISI) between visual-action stimuli and TMS pulses was varied. Before and after each m-PAS session, motor resonance was assessed by recording Motor Evoked Potentials induced by single-pulse TMS applied to the right M1, during the observation of both contralateral (left) and ipsilateral (right) index-finger movements. In the second experiment, the specificity of the m-PAS was assessed by presenting a visual stimulus depicting a non-biological movement. Results Before m-PAS, the facilitation of corticospinal excitability occurred only during the view of contralateral (with respect to the TMS side) index-finger movements. The m-PAS induced new ipsilateral motor resonance responses, indexed by atypical facilitation of corticospinal excitability by the view of ipsilateral hand movements. This effect occurred only if the associative stimulation followed the chronometry of motor control (ISI of 25 ms) and if the visual stimulus of the m-PAS depicts a biological movement (human hand action). Conclusions The present findings provide the first empirical evidence that Hebbian learning induced by a PAS protocol shapes the visual-motor matching properties of the human Mirror Neuron System

    Analysis of enhanced-performance fibre Brillouin ring laser for Brillouin sensing applications

    Get PDF
    In this work, we present an enhanced design for a Brillouin ring laser (BRL), which employs a double resonant cavity (DRC) with short fiber length, paired with a heterodyne-based wavelength-locking system, to be employed as a pump-probe source for Brillouin sensing. The enhanced source is compared to traditional long-cavity pump-probe source, showing a significantly lower relative intensity noise (~-145 dB/Hz in the whole 0\u2013800 MHz range), a narrow linewidth (10 kHz), and large tunability features, resulting in an effective pump-probe source in BOTDA systems, with an excellent pump-probe frequency stability (~200 Hz), which is uncommon for fiber lasers. The enhanced source showed an improved signal-to-noise ratio (SNR) of about 22 dB with respect to standard BRL schemes, resulting in an improved temperature/strain resolution in BOTDA applications up to 5.5 dB, with respect to previous high-noise BRL designs

    Transcranial direct current stimulation (tDCS) in unilateral cerebral palsy: A pilot study of motor effect

    Get PDF
    Transcranial Direct Current Stimulation (tDCS) is an emerging tool to improve upper limb motor functions after stroke acquired in adulthood; however, there is a paucity of reports on its efficacy for upper limb motor rehabilitation in congenital or early-acquired stroke. In this pilot study we have explored, for the first time, the immediate effects, and their short-term persistence, of a single application of anodal tDCS on chronic upper limb motor disorders in children and young individuals with Unilateral Cerebral Palsy (UCP). To this aim, in a crossover sham-controlled study, eight subjects aged 10-28 years with UCP underwent two sessions of active and sham tDCS. Anodal tDCS (1.5 mA, 20 min) was delivered over the primary motor cortex (M1) of the ipsilesional hemisphere. Results showed, only following the active stimulation, an immediate improvement in unimanual gross motor dexterity of hemiplegic, but not of nonhemiplegic, hand in Box and Block test (BBT). Such improvement remained stable for at least 90 minutes. Performance of both hands in Hand Grip Strength test was not modified by anodal tDCS. Improvement in BBT was unrelated to participants’ age or lesion size, as revealed by MRI data analysis. No serious adverse effects occurred after tDCS; some mild and transient side effects (e.g., headache, tingling, and itchiness) were reported in a limited number of cases. This study provides an innovative contribution to scientific literature on the efficacy and safety of anodal tDCS in UCP

    Strain Transfer in Surface-Bonded Optical Fiber Sensors

    Get PDF
    Fiber optic sensors represent one of the most promising technologies for the monitoring of various engineering structures. A major challenge in the field is to analyze and predict the strain transfer to the fiber core reliably. Many authors developed analytical models of a coated optical fiber, assuming null strain at the ends of the bonding length. However, this configuration only partially reflects real experimental setups in which the cable structure can be more complex and the strains do not drastically reduce to zero. In this study, a novel strain transfer model for surface-bonded sensing cables with multilayered structure was developed. The analytical model was validated both experimentally and numerically, considering two surface-mounted cable prototypes with three different bonding lengths and five load cases. The results demonstrated the capability of the model to predict the strain profile and, differently from the available strain transfer models, that the strain values at the extremities of the bonded fiber length are not null

    Simplex-Coded BOTDA Sensor Over 120 km SMF with 1 m Spatial Resolution Assisted by Optimized Bidirectional Raman Amplification

    Get PDF
    Bidirectional low-noise Raman amplification and simplex coding based on the return-to-zero modulation format are optimized through numerical simulations for long-range Brillouin optical time-domain analysis sensing. Experimental results are reported on sensing capabilities along 120-km distance with 1-m spatial resolution, and worst-case temperature and strain resolution values of 1.3 °C and 26 με, respectively

    Optical fiber sensing cables for brillouin-based distributed measurements

    Get PDF
    Brillouin distributed optical fiber sensing (Brillouin D-FOS) is a powerful technology for real-time in situ monitoring of various physical quantities, such as strain, temperature, and pressure. Compared to local or multi-point fiber optic sensing techniques, in Brillouin-based sensing, the optical fiber is interrogated along its complete length with a resolution down to decimeters and with a frequency encoding of the measure information that is not affected by changes in the optical attenuation. The fiber sensing cable plays a significant role since it must ensure a low optical loss and optimal transfer of the measured parameters for a long time and in harsh conditions, e.g., the presence of moisture, corrosion, and relevant mechanical or thermal stresses. In this paper, research and application regarding optical fiber cables for Brillouin distributed sensing are reviewed, connected, and extended. It is shown how appropriate cable design can give a significant contribution toward the successful exploitation of the Brillouin D-FOS technique

    Analysis of a distributed fiber-optic temperature sensor using single-photon detectors

    Get PDF
    We demonstrate a high-accuracy distributed fiber-optic temperature sensor using superconducting nanowire single-photon detectors and single-photon counting techniques. Our demonstration uses inexpensive single-mode fiber at standard telecommunications wavelengths as the sensing fiber, which enables extremely low-loss experiments and compatibility with existing fiber networks. We show that the uncertainty of the temperature measurement decreases with longer integration periods, but is ultimately limited by the calibration uncertainty. Temperature uncertainty on the order of 3 K is possible with spatial resolution of the order of 1 cm and integration period as small as 60 seconds. Also, we show that the measurement is subject to systematic uncertainties, such as polarization fading, which can be reduced with a polarization diversity receiver

    A Model-Assisted Probability of Detection Framework for Optical Fiber Sensors

    Get PDF
    Optical fiber sensors (OFSs) represent an efficient sensing solution in various structural health monitoring (SHM) applications. However, a well-defined methodology is still missing to quantify their damage detection performance, preventing their certification and full deployment in SHM. In a recent study, the authors proposed an experimental methodology to qualify distributed OFSs using the concept of probability of detection (POD). Nevertheless, POD curves require considerable testing, which is often not feasible. This study takes a step forward, presenting a model-assisted POD (MAPOD) approach for the first time applied to distributed OFSs (DOFSs). The new MAPOD framework applied to DOFSs is validated through previous experimental results, considering the mode I delamination monitoring of a double-cantilever beam (DCB) specimen under quasi-static loading conditions. The results show how strain transfer, loading conditions, human factors, interrogator resolution, and noise can alter the damage detection capabilities of DOFSs. This MAPOD approach represents a tool to study the effects of varying environmental and operational conditions on SHM systems based on DOFSs and for the design optimization of the monitoring system

    Motor learning in unilateral cerebral palsy and the influence of corticospinal tract reorganization

    Get PDF
    Cerebral Palsy (CP) is a complex neurological disorder, characterized by congenital motor disability associated with behaviour, perception and cognition disorders. The sensorimotor impairments represent the main hallmark of the disease, significantly impacting the quality of life. So far, few studies have investigated motor learning abilities in CP and their association with the plastic reorganization of the motor system remains largely unknown. The present proof-of-principle study explored explicit motor sequence learning in children with unilateral CP and different patterns of motor system reorganization (bilateral, ipsilateral, contralateral). Children with unilateral CP, and a group of age-matched typically developing (TD) children, underwent a sequential finger tapping task, performed with the affected hand by children with CP and with the non-dominant hand by TD children. The pattern of corticospinal tract projections in hemiparetic patients was assessed by single-pulse Transcranial Magnetic Stimulation (TMS). Results showed the presence of finger dexterity impairments in children with unilateral CP presenting with a bilateral or an ipsilateral control of the affected (trained) hand, as compared to TD children. Conversely, motor sequence learning was impaired in unilateral CP with ipsilateral or contralateral corticospinal reorganization, but not in the case of a bilateral control of the paretic hand. These preliminary findings, although referred to small clinical samples, suggest that unilateral control of the paretic upper-limb, from the ipsilateral or the contralateral motor cortex, may not be sufficient to develop typical motor learning with the affected hand, which seems to require a bilateral representation in the motor cortex. This evidence has potential implications for fine motor skills rehabilitation in CP

    No efficacy of transcranial direct current stimulation on chronic migraine with medication overuse : a double blind, randomised clinical trial

    Get PDF
    Background: Transcranial direct current stimulation was suggested to provide beneficial effects in chronic migraine, a condition often associated with medication overuse for which no long-term therapy is available. Methods: We conducted a randomised controlled trial to assess long-term efficacy of transcranial direct current stimulation. Adults diagnosed with chronic migraine and medication overuse were assigned to receive in a 1:1:1 ratio anodal, cathodal, or sham transcranial direct current stimulation daily for five consecutive days, along with standardised drug withdrawal protocol. Primary outcome was 50% reduction of days of headache per month at 12 months. Co-secondary outcomes were 50% reduction of days of headache per month at 6 months, reduction of analgesic intake per month, and change in disability and quality of life, catastrophising, depression, state and trait anxiety, dependence attitude and allodynia intensity. Patients were not allowed to take any migraine prophylaxis drug for the entire study period. Results: We randomly allocated 135 patients to anodal (44), cathodal (45), and sham (46) transcranial direct current stimulation. At 6 and 12 months, the percentage of reduction of days of headache and number of analgesics per month ranged between 48.5% and 64.7%, without differences between transcranial direct current stimulation (cathodal, anodal, or the results obtained from the two arms of treatment, anodal plus cathodal) and sham. Catastrophising attitude significantly reduced at 12 months in all groups. There was no difference for the other secondary outcomes. Conclusions: Transcranial direct current stimulation did not influence the short and long-term course of chronic migraine with medication overuse after acute drug withdrawal. Behavioral and educational measures and support for patients' pain management could provide long-term improvement and low relapse rate. Trial registration number NCT04228809
    corecore