7 research outputs found

    Channel Selection Switch for the Redundant 1.3 GHz Master Oscillator of the European XFEL

    No full text
    The phase reference signal reliability is of utmost importance for continuous operation of the European XFEL machine. Since even very short interruption or glitch in the reference signal might break the precise synchronisation between subsystems, it is desirable to minimize probability of such events. While master oscillators often have a hot-spare to speed-up recovery after a failure, whether switched manually or electronically, it does not save from time-consuming resynchronisation. Our experience from testing and commissioning E-XFEL 1.3 GHz Master Oscillator (MO) shows that a struggle to achieve demanding phase-noise requirements might negatively impact reliability of the system. In this paper we present an approach which allows for quick switching between independent reference generation channels while maintaining continuity of the output signal. This is a first step towards autonomous redundancy solution for the E-XFEL MO which will maintain continuous reference signal even in case of a failure of one of the generation channels

    Optimisation of a Low-Noise 1.3 GHz PLL Frequency Synthesizer for the European XFEL

    No full text
    The Master Oscillator system of the European XFEL was built using frequency synthesis techniques that were found to have the best phase noise performance. This includes low noise frequency multipliers and nonÂmultiplying phase lock loops, incorporated in the system to shape its output phase noise spectrum. Jitter of the output signal strongly depends on phase noise transmittance of the PLL and suboptimal design can worsen it by orders of magnitude. Taking into consideration that the PLL open loop transmittance usually can be shaped in multiple ways, and that the accurate phase noise measurements can easily take more than 30 minutes, designing an automated tool becomes a necessity. For this purpose an approach to the tuning system construction was chosen in order to make the phase noise optimisation process simpler. This paper describes the optimisation of PLL synthesizer phase noise, done to improve the performance of the European XFEL MO. We present the phase noise optimisation process and achieved results

    LLRF Commissioning at the European XFEL

    No full text
    The European X-ray Free-Electron Laser (XFEL) at Deutsches Elektronen-Synchrotron (DESY), Hamburg, Germany is a user facility under commissioning, providing ultrashort X-ray flashes with a high brilliance in the near future. All LLRF stations of the injector, covering the normal conducting RF gun, A1 (8 1.3 GHz superconducting cavities (SCs) and AH1 (8 3.9 GHz SCs), were successfully commissioned by the end of 2015. The injector was operated with beam transmission to the injector dump since then. After the conclusion of the construction work in the XFEL accelerator tunnel (XTL), the commissioning of 22 LLRF stations (A2 to A23) started with the beginning of 2017. Every station consists of a semi-distributed LLRF system controlling 32 1.3 GHz SCs. Stable operation with beam transport to the main dump (TLD) was achieved. The commissioning procedure applied, experience gained and performance reached are described

    The relation of rapid changes in obesity measures to lipid profile - insights from a nationwide metabolic health survey in 444 Polish cities

    Get PDF
    Objective The impact of fast changes in obesity indices on other measures of metabolic health is poorly defined in the general population. Using the Polish accession to the European Union as a model of political and social transformation we examined how an expected rapid increase in body mass index (BMI) and waist circumference relates to changes in lipid profile, both at the population and personal level. Methods Through primary care centres in 444 Polish cities, two cross-sectional nationwide population-based surveys (LIPIDOGRAM 2004 and LIPIDOGRAM 2006) examined 15,404 and 15,453 adult individuals in 2004 and 2006, respectively. A separate prospective sample of 1,840 individuals recruited in 2004 had a follow-up in 2006 (LIPIDOGRAM PLUS). Results Two years after Polish accession to European Union, mean population BMI and waist circumference increased by 0.6% and 0.9%, respectively. This tracked with a 7.6% drop in HDL-cholesterol and a 2.1% increase in triglycerides (all p<0.001) nationwide. The direction and magnitude of the population changes were replicated at the personal level in LIPIDOGRAM PLUS (0.7%, 0.3%, 8.6% and 1.8%, respectively). However, increases in BMI and waist circumference were both only weakly associated with HDL-cholesterol and triglycerides changes prospectively. The relation of BMI to the magnitude of change in both lipid fractions was comparable to that of waist circumference. Conclusions Moderate changes in obesity measures tracked with a significant deterioration in measures of pro-atherogenic dyslipidaemia at both personal and population level. These associations were predominantly driven by factors not measureable directly through either BMI or waist circumference
    corecore