33 research outputs found
Reply to Comment on "High-Precision Determination of the Electric and Magnetic Form Factors of the Proton"
In arXiv:1108.3058v1 [nucl-ex], Arrington criticizes the Coulomb corrections
we applied in the analysis of high precision form factor data (see
Phys.Rev.Lett.105:242001, 2010, arXiv:1007.5076v3 [nucl-ex]). We show, by
comparing different calculations cited in the Comment, that the criticism of
the Comment neglects the large uncertainty of "more modern" TPE corrections.
This uncertainty has also been seen in recent polarized measurements. We rerun
our analysis using one of these calculations. The results show that the Comment
exaggerates the quantitative effect at small Q^2.Comment: 1 page, 2 figure, To appear as a Reply Comment in Physical Review
Letter
The electric and magnetic form factors of the proton
The paper describes a precise measurement of electron scattering off the
proton at momentum transfers of \ GeV. The
average point-to-point error of the cross sections in this experiment is
0.37%. These data are used for a coherent new analysis together with all world
data of unpolarized and polarized electron scattering from the very smallest to
the highest momentum transfers so far measured. The extracted electric and
magnetic form factors provide new insight into their exact shape, deviating
from the classical dipole form, and of structure on top of this gross shape.
The data reaching very low values are used for a new determination of the
electric and magnetic radii. An empirical determination of the
Two-Photon-Exchange (TPE) correction is presented. The implications of this
correction on the radii and the question of a directly visible signal of the
pion cloud are addressed.Comment: 38 pages, 20 figures. Updated data files. PRC versio
High-precision determination of the electric and magnetic form factors of the proton
New precise results of a measurement of the elastic electron-proton
scattering cross section performed at the Mainz Microtron MAMI are presented.
About 1400 cross sections were measured with negative four-momentum transfers
squared up to Q^2=1 (GeV/c)^2 with statistical errors below 0.2%. The electric
and magnetic form factors of the proton were extracted by fits of a large
variety of form factor models directly to the cross sections. The form factors
show some features at the scale of the pion cloud. The charge and magnetic
radii are determined to be r_E=0.879(5)(stat.)(4)(syst.)(2)(model)(4)(group) fm
and r_M=0.777(13)(stat.)(9)(syst.)(5)(model)(2)(group) fm.Comment: 5 pages, 2 figures, published in Phys. Rev. Lett. v3: added
references, updated text, color figure
A Large-Scale FPGA-Based Trigger and Dead-Time Free DAQ System for the Kaos Spectrometer at MAMI
The Kaos spectrometer is maintained by the A1 collaboration at the Mainz
Microtron MAMI with a focus on the study of (e,e'K^+) coincidence reactions.
For its electron-arm two vertical planes of fiber arrays, each comprising
approximately 10 000 fibers, are operated close to zero degree scattering angle
and in close proximity to the electron beam. A nearly dead-time free DAQ system
to acquire timing and tracking information has been installed for this
spectrometer arm. The signals of 144 multi-anode photomultipliers are collected
by 96-channel front-end boards, digitized by double-threshold discriminators
and the signal time is picked up by state-of-the-art F1 time-to-digital
converter chips. In order to minimize background rates a sophisticated trigger
logic was implemented in newly developed Vuprom modules. The trigger performs
noise suppression, signal cluster finding, particle tracking, and coincidence
timing, and can be expanded for kinematical matching (e'K^+) coincidences. The
full system was designed to process more than 4 000 read-out channels and to
cope with the high electron flux in the spectrometer and the high count rate
requirement of the detectors. It was successfully in-beam tested at MAMI in
2009.Comment: Contributed to 17th IEEE Real Time Conference (RT10), Lisbon, 24-28
May 201
Particle tracking in kaon electroproduction with cathode-charge sampling in multi-wire proportional chambers
Wire chambers are routinely operated as tracking detectors in magnetic
spectrometers at high-intensity continuous electron beams. Especially in
experiments studying reactions with small cross-sections the reaction yield is
limited by the background rate in the chambers. One way to determine the track
of a charged particle through a multi-wire proportional chamber (MWPC) is the
measurement of the charge distribution induced on its cathodes. In practical
applications of this read-out method, the algorithm to relate the measured
charge distribution to the avalanche position is an important factor for the
achievable position resolution and for the track reconstruction efficiency. An
algorithm was developed for operating two large-sized MWPCs in a strong
background environment with multiple-particle tracks. Resulting efficiencies
were determined as a function of the electron beam current and on the signal
amplitudes. Because of the different energy-losses of pions, kaons, and protons
in the momentum range of the spectrometer the efficiencies depend also on the
particle species
Search for light massive gauge bosons as an explanation of the anomaly at MAMI
A massive, but light abelian U(1) gauge boson is a well motivated possible
signature of physics beyond the Standard Model of particle physics. In this
paper, the search for the signal of such a U(1) gauge boson in
electron-positron pair-production at the spectrometer setup of the A1
Collaboration at the Mainz Microtron (MAMI) is described. Exclusion limits in
the mass range of 40 MeV up to 300 MeV with a sensitivity in the mixing
parameter of down to are presented. A large
fraction of the parameter space has been excluded where the discrepancy of the
measured anomalous magnetic moment of the muon with theory might be explained
by an additional U(1) gauge boson.Comment: 4 pages, 3 figure
Exclusive electroproduction of K+ Lambda and K+ Sigma^0 final states at Q^2 = 0.030-0.055 (GeV/c)^2
Cross section measurements of the exclusive p(e,e'K+)Lambda,Sigma^0
electroproduction reactions have been performed at the Mainz Microtron MAMI in
the A1 spectrometer facility using for the first time the Kaos spectrometer for
kaon detection. These processes were studied in a kinematical region not
covered by any previous experiment. The nucleon was probed in its third
resonance region with virtual photons of low four-momenta, Q^2= 0.030-0.055
(GeV/c)^2. The MAMI data indicate a smooth transition in Q^2 from
photoproduction to electroproduction cross sections. Comparison with
predictions of effective Lagrangian models based on the isobar approach reveal
that strong longitudinal couplings of the virtual photon to the N* resonances
can be excluded from these models.Comment: 16 pages, 7 figure
In-beam tests of scintillating fibre detectors at MAMI and at GSI
The performance of scintillating fibre detectors was studied with electrons
at the spectrometer facility of the Mainz microtron MAMI, as well as in a C-12
beam of 2 AGeV energy and in a beam of different particle species at GSI.
Multi-anode photomultipliers were used to read out one or more bundles of 128
fibres each in different geometries. For electrons a time resolution of FWHM =
1 ns was measured in a single detector plane with a detection efficiency
epsilon > 99%. A time resolution of 310 ps (FWHM) between two planes of fibres
was achieved for carbon ions, leading to a FWHM = 220 ps for a single detector.
The hit position residual was measured with a width of FWHM = 0.27 mm. The
variation in the measured energy deposition was Delta E/E= 15-20% (FWHM) for
carbon ions. In addition, the energy response to p/pi/d particles was studied.
Based on the good detector performance fibre hodoscopes will be constructed for
the KAOS/A1 spectrometer at MAMI and for the HypHI experiment at GSI.Comment: submitted to Nucl. Instrum. Meth.
The HIV-1 reservoir landscape in persistent elite controllers and transient elite controllers.
BACKGROUNDPersistent controllers (PCs) maintain antiretroviral-free HIV-1 control indefinitely over time, while transient controllers (TCs) eventually lose virological control. It is essential to characterize the quality of the HIV reservoir in terms of these phenotypes in order to identify the factors that lead to HIV progression and to open new avenues toward an HIV cure.METHODSThe characterization of HIV-1 reservoir from peripheral blood mononuclear cells was performed using next-generation sequencing techniques, such as full-length individual and matched integration site proviral sequencing (FLIP-Seq; MIP-Seq).RESULTSPCs and TCs, before losing virological control, presented significantly lower total, intact, and defective proviruses compared with those of participants on antiretroviral therapy (ART). No differences were found in total and defective proviruses between PCs and TCs. However, intact provirus levels were lower in PCs compared with TCs; indeed the intact/defective HIV-DNA ratio was significantly higher in TCs. Clonally expanded intact proviruses were found only in PCs and located in centromeric satellite DNA or zinc-finger genes, both associated with heterochromatin features. In contrast, sampled intact proviruses were located in permissive genic euchromatic positions in TCs.CONCLUSIONSThese results suggest the need for, and can give guidance to, the design of future research to identify a distinct proviral landscape that may be associated with the persistent control of HIV-1 without ART.FUNDINGInstituto de Salud Carlos III (FI17/00186, FI19/00083, MV20/00057, PI18/01532, PI19/01127 and PI22/01796), Gilead Fellowships (GLD22/00147). NIH grants AI155171, AI116228, AI078799, HL134539, DA047034, MH134823, amfAR ARCHE and the Bill and Melinda Gates Foundation