57 research outputs found

    Cooling Average Potential of Evaporative Cooling System in Dry Warm Climate

    Get PDF
    AbstractThe high summer temperatures, high solar radiation and common inadequate thermal design of buildings obliges the occupants to recur to the use cooling equipment such as evaporative air-conditioning to achieve acceptable levels of habitability. Evaporative cooling systems require considerable electric energy and a significant constant clean water supply during operation. Therefore, this paper presents the results of a field study aims to quantify in this kind of weather, the potential cooling means having the following strategies: indirect evaporative cooling and shading devices; indirect evaporative cooling, shading devices and thermal mass; indirect evaporative cooling, solar protection, thermal mass and nocturnal radiative cooling; indirect evaporative cooling, thermal insulation and nocturnal radiative cooling; and finally indirect evaporative cooling, thermal insulation, thermal mass and nocturnal radiative cooling. The method consisted of measuring the reduction in air temperature is achieved with each of these cooling strategies, applied in three research modules of same construction features, orientation and dimensions during the summer 2012.Then quantified the cooling average potential by the method proposed by Dr. Eduardo Gonzalez (1989). Finally registration was the water consumption with each of these strategies and estimated required consumption by direct evaporative cooling to achieve the same cooling potential. The results obtained indicate that the IEC/TI/NRC had cooling potential of 822.89 Wh/m2day, followed IEC/SP with 764.19 Wh/m2day and finally IEC/SP+TM 568.60 Wh/m2day

    Confort higrotérmico para actividades en espacios exteriores: periodo cálido, en clima cálido seco extremo

    Get PDF
    El tiempo de duración de las actividades en espacios exteriores en clima cálido seco extremo, depende de las condiciones de confort higrotérmico de los usuarios. Además por condiciones de ambiente térmico existen riesgos como deshidratación o golpe de calor. El objetivo del presente estudio fue estimar condiciones confort por temperatura y humedad relativa de usuarios de espacios exteriores de un centro recreativo de Mexicali, Baja California, México. Se presenta la estimación de temperatura y humedad relativa neutral con rangos de confort térmico para espacios exteriores, en el período cálido en un clima desértico. Se diseñó un cuestionario basado en ISO 10551, se midieron temperatura de bulbo seco y humedad relativa. Se aplicaron 822 encuestas en julio y agosto del 2008. Se estimaron temperatura y humedad relativa neutra y rangos de confort con el método de medias por intervalo de sensación térmica. El análisis se hizo para tres niveles de actividad: pasiva, moderada e intensa y uno combinado con los tres niveles. El período analizado presentó un comportamiento de clima asimétrico. Los valores de temperatura son aproximadamente simétricos con respecto a sus rangos de confort térmico, mientras que el confort por humedad relativa en actividad moderada e intensa fue asimétrico. Las temperaturas y humedad relativa neutras obtenidas muestran que los sujetos en actividad intensa, con práctica periódica de ejercicio y hábitos apropiados a las condiciones de clima, tienen una temperatura y humedad relativa de confort similar a aquellos con actividad pasiva.The duration of outdoor activities in extreme dry in warm weather, depends on the hygrothermal comfort conditions for users. In addition to the thermal environment conditions there are risks such as dehydration or Heat Stroke. The objective of this study was to estimate the comfort conditions for temperature and relative humidity of outdoor users of a recreational center in Mexicali, Baja California, Mexico. This work shows the estimated neutral temperatura, neutral relative humidity and thermal comfort ranges during the warm period for a public recreational green area located on a desert climate. A questionnaire was designed based on the scale of thermal sensation of ISO 10551 were measured dry bulb temperatura and relative humidity. A total of 822 questionnaires were applied during the months of July and August 2008. By estimated neutral temperatura, neutral relative humidity and comfort range with a statistical method of correlation. The analysis was done for three activity levels: passive, moderate e intense, besides the three levels together. The period of climate analyzed was asymmetric. The neutral temperature values obtained are approximately symmetrical with respect to the thermal comfort range, while the relative humidity comfort for moderate and intensity activity was asymmetric. The neutral temperatures and relative humidity obtained show that the intense activity in subjects with regular exercise and practice habits appropriate to the weather conditions, had a temperature of comfort similar to subjects with passive activity.Peer Reviewe

    Percentage of hours of thermal comfort with indirect evaporative cooling techniques in roof ponds in an arid climate

    Get PDF
    This document presents a comparative study of the percentage of time that the operating temperature is located within the limits of the comfort zone proposed by ASHRAE Standard 55-2010 for naturally ventilated buildings. The temperatures studied were recorded inside of experimental roof pond modules, located in a warm, dry climate. Five passive cooling techniques were applied to the modules. The experiment was carried out in Chihuahua, Mexico (Lat.: 28N, Long.: 106W, altitude: 1,425m) during the summer of 2012. The results indicate that roof ponds are an excellent alternative to increase the percentage of hours of comfort, because they provide up to 30% more hours on average with respect to a control module without a roof pond. If radiative cooling is added at night, the percentage increases to 40%, and incorporating thermal mass it increases up to 65%. Even, in some cases, the cooling is so intense that it exceeds the lower range of comfort in morning hours.En este documento se presenta un estudio comparativo del porcentaje de tiempo en que la temperatura operativa se ubica dentro de los límites de la zona de confort propuesta por la norma ASHRAE 55-2010 para edificios libremente ventilados. Las temperaturas estudiadas se registraron al interior de módulos experimentales con techo estanque, emplazados en clima cálido seco, a los que les fueron aplicadas cinco técnicas de enfriamiento pasivo. El experimento se llevó a cabo en Chihuahua, México (Lat.: 28N, Long.: 106W, altura: 1.425m) durante el verano de 2012. Los resultados indican que el techo estanque es una excelente alternativa para incrementar el porcentaje de horas de confort, pues se alcanza hasta un 30% más horas en promedio, respecto de un módulo control sin techo estanque. Si se añade enfriamiento radiativo nocturno, el porcentaje aumenta a 40%, e incorporando masa térmica, se incrementa hasta en un 65%. Incluso, en algunos casos, el enfriamiento es tan intenso que se sobrepasa el rango inferior de confort en horas de las mañanas

    Affordable Housing for Hot and Sub-Humid Climate in Mexico as Result of a Thermal Comfort Study

    Get PDF
    El artículo presenta un prototipo de vivienda de bajo costo desarrollada con base en estudios de campo llevados a cabo en Colima, México (clima cálido sub-húmedo). Los estudios de campo se dirigieron a un tipo de vivienda promovido por el gobierno mexicano, llamado “vivienda económica”. Son viviendas de 45 m2 construidas con muros de block de cemento y cubiertas con losas de concreto, sin aislamiento térmico. Su diseño atiende a requerimientos de costo, pero carece de criterios sobre eficiencia energética y confort térmico. A partir de los resultados de la investigación, estudiantes asesorados por profesores desarrollaron un proyecto arquitectónico, utilizando estrategias bioclimáticas como dispositivos de sombreado, masa térmica, ventilación natural (ventilación cruzada), ventilación inducida (efecto stack) y ventilación nocturna (intercambio de radiación de onda larga).A prototype of low-cost housing developed on basis of field studies carried out in Colima, Mexico (hot and sub-humid climate) is presented. Field studies were addressed to a type of affordable housing promoted by the Mexican government, called ‘vivienda económica’. These 45 m2 housings are constructed of concrete block walls and concrete slabs for roofs, without any kind of thermal insulation. Their design concept only attends cost requirements, but it lacks criteria on energy efficiency and thermal comfort. Consequently, their occupants have adapted to extreme temperatures. Besides the thermal evaluation of pre-existing housing, two field studies were carried out consisted in a poll about the occupants’ opinion concerning their houses and a thermal comfort survey according to ISO 10551, within the adaptive model approach. With results of such inquiries, undergraduate students advised by professors developed an architectural project. Main bioclimatic strategies considered were shading devices, thermal mass, natural ventilation (cross ventilation), winds induced ventilation (stack effect) and nocturnal ventilation (long-wave radiation exchange).Universidad Veracruzana

    Suicidio: La muerte ignorada ¿Se puede prevenir el suicidio?

    Get PDF
    Suicide is perhaps the most devastating death, for both the suicidal, and those who survive him. Suicide is not a disease in itself but a behavior, the final pathway resulting from various risk factors: major mental illness and previous suicide attempts as the most important, medical illnesses that present with chronic pain, disabling, or determining disability or cognitive impairment, stressful life events, especially the loss or emotional breakdowns, and finally the social isolation. Treatment of patients with suicidal behavior includes pharmacotherapy, psychotherapy and social interventions. A review of the most effective is carried out.El suicidio es posiblemente la muerte más desoladora, tanto para el suicida como para los que le sobreviven. El suicidio no es en sí mismo una enfermedad, es una conducta, la vía final resultado de diversos factores de riesgo: los principales son la enfermedad mental y los intentos de suicidio previos; las enfermedades médicas que cursan con dolor crónico, incapacitantes, o las que determinen secuelas o deterioro cognitivo; los acontecimientos vitales estresantes, especialmente las pérdidas o rupturas afectivas y finalmente el desarraigo y aislamiento social. El tratamiento de los pacientes con conductas suicidas incluye la farmacoterapia, la psicoterapia y las intervenciones sociales. Se realiza una revisión de los más efectivos

    El posgrado en Arquitectura de la Universidad de Colima : El caso de las áreas de diseño bioclimático y de desarrollo urbano

    Get PDF
    A partir de 1986, la Universidad de Colima empezó a ofrecer el posgrado en Arquitectura, en la línea del Diseño Bioclimático, uno de los primeros programas en México con esta temática; desde entonces, el plan de estudios de la maestría se ha modificado, actualmente ofrece cuatro áreas de especialidad; además de un programa internacional que se imparte bajo el nombre de Maestría en Diseño Bioclimático en la Ciudad de Panamá, Panamá. La oferta educativa en el posgrado se completa con el doctorado en arquitectura; a partir de este año, la maestría y el doctorado en Arquitectura son de los pocos programas de calidad reconocidos en el padrón nacional de posgrado del Consejo Nacional de Ciencia y Tecnología, dentro del área de Arquitectura.In 1986, the University of Colima began to offer the Bioclimatic Design specialty in the Architecture Master, becoming one of the first programs involved in this theme in Mexico. Since then, the curriculum of the master has been modified, so that at present it offers four areas of specialty, including an international program that is given under the name of Master in Bioclimatic Design in Panama City, Panama. This educational offering is completed with the doctorate in architecture, in such a way that from this year, the master and doctorate in Architecture are of the few programs of quality recognized in the Registry of Graduate Programs of Excellence (PPE) of the Mexican National Council of Science and Technology (CONACYT), within the Architecture specialty. This paper is a retrospective of the successes in the development of this program and what is necessary to do to yet.Asociación Argentina de Energías Renovables y Medio Ambiente (ASADES

    El posgrado en Arquitectura de la Universidad de Colima : El caso de las áreas de diseño bioclimático y de desarrollo urbano

    Get PDF
    A partir de 1986, la Universidad de Colima empezó a ofrecer el posgrado en Arquitectura, en la línea del Diseño Bioclimático, uno de los primeros programas en México con esta temática; desde entonces, el plan de estudios de la maestría se ha modificado, actualmente ofrece cuatro áreas de especialidad; además de un programa internacional que se imparte bajo el nombre de Maestría en Diseño Bioclimático en la Ciudad de Panamá, Panamá. La oferta educativa en el posgrado se completa con el doctorado en arquitectura; a partir de este año, la maestría y el doctorado en Arquitectura son de los pocos programas de calidad reconocidos en el padrón nacional de posgrado del Consejo Nacional de Ciencia y Tecnología, dentro del área de Arquitectura.In 1986, the University of Colima began to offer the Bioclimatic Design specialty in the Architecture Master, becoming one of the first programs involved in this theme in Mexico. Since then, the curriculum of the master has been modified, so that at present it offers four areas of specialty, including an international program that is given under the name of Master in Bioclimatic Design in Panama City, Panama. This educational offering is completed with the doctorate in architecture, in such a way that from this year, the master and doctorate in Architecture are of the few programs of quality recognized in the Registry of Graduate Programs of Excellence (PPE) of the Mexican National Council of Science and Technology (CONACYT), within the Architecture specialty. This paper is a retrospective of the successes in the development of this program and what is necessary to do to yet.Asociación Argentina de Energías Renovables y Medio Ambiente (ASADES

    El posgrado en Arquitectura de la Universidad de Colima : El caso de las áreas de diseño bioclimático y de desarrollo urbano

    Get PDF
    A partir de 1986, la Universidad de Colima empezó a ofrecer el posgrado en Arquitectura, en la línea del Diseño Bioclimático, uno de los primeros programas en México con esta temática; desde entonces, el plan de estudios de la maestría se ha modificado, actualmente ofrece cuatro áreas de especialidad; además de un programa internacional que se imparte bajo el nombre de Maestría en Diseño Bioclimático en la Ciudad de Panamá, Panamá. La oferta educativa en el posgrado se completa con el doctorado en arquitectura; a partir de este año, la maestría y el doctorado en Arquitectura son de los pocos programas de calidad reconocidos en el padrón nacional de posgrado del Consejo Nacional de Ciencia y Tecnología, dentro del área de Arquitectura.In 1986, the University of Colima began to offer the Bioclimatic Design specialty in the Architecture Master, becoming one of the first programs involved in this theme in Mexico. Since then, the curriculum of the master has been modified, so that at present it offers four areas of specialty, including an international program that is given under the name of Master in Bioclimatic Design in Panama City, Panama. This educational offering is completed with the doctorate in architecture, in such a way that from this year, the master and doctorate in Architecture are of the few programs of quality recognized in the Registry of Graduate Programs of Excellence (PPE) of the Mexican National Council of Science and Technology (CONACYT), within the Architecture specialty. This paper is a retrospective of the successes in the development of this program and what is necessary to do to yet.Asociación Argentina de Energías Renovables y Medio Ambiente (ASADES
    corecore