825 research outputs found

    First NuSTAR Observations of Mrk 501 within a Radio to TeV Multi-Instrument Campaign

    Get PDF
    We report on simultaneous broadband observations of the TeV-emitting blazar Markarian 501 between 1 April and 10 August 2013, including the first detailed characterization of the synchrotron peak with Swift and NuSTAR. During the campaign, the nearby BL Lac object was observed in both a quiescent and an elevated state. The broadband campaign includes observations with NuSTAR, MAGIC, VERITAS, the Fermi Large Area Telescope (LAT), Swift X-ray Telescope and UV Optical Telescope, various ground-based optical instruments, including the GASP-WEBT program, as well as radio observations by OVRO, Metsähovi and the F-Gamma consortium. Some of the MAGIC observations were affected by a sand layer from the Saharan desert, and had to be corrected using event-by-event corrections derived with a LIDAR (LIght Detection And Ranging) facility. This is the first time that LIDAR information is used to produce a physics result with Cherenkov Telescope data taken during adverse atmospheric conditions, and hence sets a precedent for the current and future ground-based gamma-ray instruments. The NuSTAR instrument provides unprecedented sensitivity in hard X-rays, showing the source to display a spectral energy distribution between 3 and 79 keV consistent with a log-parabolic spectrum and hard X-ray variability on hour timescales. None (of the four extended NuSTAR observations) shows evidence of the onset of inverse-Compton emission at hard X-ray energies. We apply a single-zone equilibrium synchrotron self-Compton model to five simultaneous broadband spectral energy distributions. We find that the synchrotron self-Compton model can reproduce the observed broadband states through a decrease in the magnetic field strength coinciding with an increase in the luminosity and hardness of the relativistic leptons responsible for the high-energy emission

    Patient and public involvement in patient safety research: a workshop to review patient information, minimise psychological risk and inform research

    Get PDF
    Background Patient safety has attracted increasing attention in recent years. This paper explores patients’ contributions to informing patient safety research at an early stage, within a project on intravenous infusion errors. Currently, there is little or no guidance on how best to involve patients and the wider public in shaping patient safety research, and indeed, whether such efforts are worthwhile. Method We ran a 3-hour workshop involving nine patients with experience of intravenous therapy in the hospital setting. The first part explored patients’ experiences of intravenous therapy. We derived research questions from the resulting discussion through qualitative analysis. In the second part, patients were asked for feedback on patient information sheets considering both content and clarity, and on two potential approaches to framing our patient information: one that focused on research on safety and error, the other on quality improvement. Results The workshop led to a thorough review of how we should engage with patients. Importantly, there was a clear steer away from terms such as ‘error’ and ‘safety’ that could worry patients. The experiences that patients revealed were also richer than we had anticipated, revealing different conceptions of how patients related to their treatment and care, their role in safety and use of medical devices, the different levels of information they preferred, and broader factors impacting perceptions of their care. Conclusion Involving patients at an early stage in patient safety research can be of great value. Our workshop highlighted sensitivities around potentially worrying patients about risks that they might not have considered previously, and how to address these. Patient representatives also emphasised a need to expand the focus of patient safety research beyond clinicians and error, to include factors affecting perceptions of quality and safety for patients more broadly

    Direct measurement of stellar angular diameters by the VERITAS Cherenkov Telescopes

    Full text link
    The angular size of a star is a critical factor in determining its basic properties. Direct measurement of stellar angular diameters is difficult: at interstellar distances stars are generally too small to resolve by any individual imaging telescope. This fundamental limitation can be overcome by studying the diffraction pattern in the shadow cast when an asteroid occults a star, but only when the photometric uncertainty is smaller than the noise added by atmospheric scintillation. Atmospheric Cherenkov telescopes used for particle astrophysics observations have not generally been exploited for optical astronomy due to the modest optical quality of the mirror surface. However, their large mirror area makes them well suited for such high-time-resolution precision photometry measurements. Here we report two occultations of stars observed by the VERITAS Cherenkov telescopes with millisecond sampling, from which we are able to provide a direct measurement of the occulted stars' angular diameter at the ≤0.1\leq0.1 milliarcsecond scale. This is a resolution never achieved before with optical measurements and represents an order of magnitude improvement over the equivalent lunar occultation method. We compare the resulting stellar radius with empirically derived estimates from temperature and brightness measurements, confirming the latter can be biased for stars with ambiguous stellar classifications.Comment: Accepted for publication in Nature Astronom

    A Search for Very High-Energy Gamma Rays from the Missing Link Binary Pulsar J1023+0038 with VERITAS

    Full text link
    The binary millisecond radio pulsar PSR J1023+0038 exhibits many characteristics similar to the gamma-ray binary system PSR B1259--63/LS 2883, making it an ideal candidate for the study of high-energy non-thermal emission. It has been the subject of multi-wavelength campaigns following the disappearance of the pulsed radio emission in 2013 June, which revealed the appearance of an accretion disk around the neutron star. We present the results of very high-energy gamma-ray observations carried out by VERITAS before and after this change of state. Searches for steady and pulsed emission of both data sets yield no significant gamma-ray signal above 100 GeV, and upper limits are given for both a steady and pulsed gamma-ray flux. These upper limits are used to constrain the magnetic field strength in the shock region of the PSR J1023+0038 system. Assuming that very high-energy gamma rays are produced via an inverse-Compton mechanism in the shock region, we constrain the shock magnetic field to be greater than ∼\sim2 G before the disappearance of the radio pulsar and greater than ∼\sim10 G afterwards.Comment: 7 pages, 3 figures, accepted for publication in Ap

    Very-high-energy observations of the binaries V 404 Cyg and 4U 0115+634 during giant X-ray outbursts

    Full text link
    Transient X-ray binaries produce major outbursts in which the X-ray flux can increase over the quiescent level by factors as large as 10710^7. The low-mass X-ray binary V 404 Cyg and the high-mass system 4U 0115+634 underwent such major outbursts in June and October 2015, respectively. We present here observations at energies above hundreds of GeV with the VERITAS observatory taken during some of the brightest X-ray activity ever observed from these systems. No gamma-ray emission has been detected by VERITAS in 2.5 hours of observations of the microquasar V 404 Cyg from 2015, June 20-21. The upper flux limits derived from these observations on the gamma-ray flux above 200 GeV of F <4.4×10−12< 4.4\times 10^{-12} cm−2^{-2} s−1^{-1} correspond to a tiny fraction (about 10−610^{-6}) of the Eddington luminosity of the system, in stark contrast to that seen in the X-ray band. No gamma rays have been detected during observations of 4U 0115+634 in the period of major X-ray activity in October 2015. The flux upper limit derived from our observations is F <2.1×10−12< 2.1\times 10^{-12} cm−2^{-2} s−1^{-1} for gamma rays above 300 GeV, setting an upper limit on the ratio of gamma-ray to X-ray luminosity of less than 4%.Comment: Accepted for publication in the Astrophysical Journa

    Very-High-Energy γ\gamma-Ray Observations of the Blazar 1ES 2344+514 with VERITAS

    Full text link
    We present very-high-energy γ\gamma-ray observations of the BL Lac object 1ES 2344+514 taken by the Very Energetic Radiation Imaging Telescope Array System (VERITAS) between 2007 and 2015. 1ES 2344+514 is detected with a statistical significance above background of 20.8σ20.8\sigma in 47.247.2 hours (livetime) of observations, making this the most comprehensive very-high-energy study of 1ES 2344+514 to date. Using these observations the temporal properties of 1ES 2344+514 are studied on short and long times scales. We fit a constant flux model to nightly- and seasonally-binned light curves and apply a fractional variability test, to determine the stability of the source on different timescales. We reject the constant-flux model for the 2007-2008 and 2014-2015 nightly-binned light curves and for the long-term seasonally-binned light curve at the >3σ> 3\sigma level. The spectra of the time-averaged emission before and after correction for attenuation by the extragalactic background light are obtained. The observed time-averaged spectrum above 200 GeV is satisfactorily fitted (χ2/NDF=7.89/6{\chi^2/NDF = 7.89/6}) by a power-law function with index Γ=2.46±0.06stat±0.20sys\Gamma = 2.46 \pm 0.06_{stat} \pm 0.20_{sys} and extends to at least 8 TeV. The extragalactic-background-light-deabsorbed spectrum is adequately fit (χ2/NDF=6.73/6{\chi^2/NDF = 6.73/6}) by a power-law function with index Γ=2.15±0.06stat±0.20sys\Gamma = 2.15 \pm 0.06_{stat} \pm 0.20_{sys} while an F-test indicates that the power-law with exponential cutoff function provides a marginally-better fit (χ2/NDF\chi^2/NDF = 2.56/52.56 / 5 ) at the 2.1σ\sigma level. The source location is found to be consistent with the published radio location and its spatial extent is consistent with a point source.Comment: 7 pages, 2 figures. Published in Monthly Notices of the Royal Astronomical Societ
    • …
    corecore