4,980 research outputs found

    Determination of complex dielectric functions of ion implanted and implanted‐annealed amorphous silicon by spectroscopic ellipsometry

    Get PDF
    Measuring with a spectroscopic ellipsometer (SE) in the 1.8–4.5 eV photon energy region we determined the complex dielectric function (Ï” = Ï”1 + iÏ”2) of different kinds of amorphous silicon prepared by self‐implantation and thermal relaxation (500 °C, 3 h). These measurements show that the complex dielectric function (and thus the complex refractive index) of implanted a‐Si (i‐a‐Si) differs from that of relaxed (annealed) a‐Si (r‐a‐Si). Moreover, its Ï” differs from the Ï” of evaporated a‐Si (e‐a‐Si) found in the handbooks as Ï” for a‐Si. If we use this Ï” to evaluate SE measurements of ion implanted silicon then the fit is very poor. We deduced the optical band gap of these materials using the Davis–Mott plot based on the relation: (Ï”2E2)1/3 ∌ (E− Eg). The results are: 0.85 eV (i‐a‐Si), 1.12 eV (e‐a‐Si), 1.30 eV (r‐a‐Si). We attribute the optical change to annihilation of point defects

    Ösophagus- und Magenkarzinom

    Get PDF

    Gastroenterologische NotfÀlle

    Get PDF

    Funktionelle Magnetresonanzbildgebung des Verdauungstrakts: Klinische Anwendungsmöglichkeiten?

    Get PDF
    Zusammenfassung: Die Magnetresonanztomographie (MRT) stellt eine vielseitige bildgebende Methode in der Medizin dar, fĂŒr welche ein Spektrum neuer diagnostischer Optionen entwickelt wurde. Neben der in der klinischen Praxis etablierten Darstellung von Organstrukturen, wird die MRT zunehmend zur Bildgebung humaner Organfunktionen wie zum Beispiel des Herzen und des zentralen Nervensystems herangezogen. Der Einsatz zur funktionellen Bildgebung des Verdauungstrakts ist neuartig und erfolgt an wenigen Zentren im Bereich der Grundlagen- und klinischen Forschung. Die hochauflösende kontrastreiche schnelle Bildgebung, die fehlende Belastung durch ionisierende Strahlung und die UntersucherunabhĂ€ngigkeit in der Bildakquisition und Analyse machen die MRT zu einer idealen Methode der Funktionsdiagnostik des Verdauungstrakts. In dieser Übersicht werden gegenwĂ€rtige Anwendungen der MRT in der gastroenterolgischen Funktionsdiagnostik vorgestellt und mit herkömmlichen diagnostischen Methoden vergliche

    Bayesian photon counting with electron-multiplying charge coupled devices (EMCCDs)

    Get PDF
    The EMCCD is a CCD type that delivers fast readout and negligible detector noise, making it an ideal detector for high frame rate applications. Because of the very low detector noise, this detector can potentially count single photons. Considering that an EMCCD has a limited dynamical range and negligible detector noise, one would typically apply an EMCCD in such a way that multiple images of the same object are available, for instance, in so called lucky imaging. The problem of counting photons can then conveniently be viewed as statistical inference of flux or photon rates, based on a stack of images. A simple probabilistic model for the output of an EMCCD is developed. Based on this model and the prior knowledge that photons are Poisson distributed, we derive two methods for estimating the most probable flux per pixel, one based on thresholding, and another based on full Bayesian inference. We find that it is indeed possible to derive such expressions, and tests of these methods show that estimating fluxes with only shot noise is possible, up to fluxes of about one photon per pixel per readout.Comment: Fixed a few typos compared to the published versio

    Nonlocal spectral properties of disordered alloys

    Full text link
    A general method is proposed for calculating a fully k-dependent, continuous, and causal spectral function A(k,E) within the recently introduced nonlocal version of the coherent-potential approximation (NLCPA). The method involves the combination of both periodic and anti-periodic solutions to the associated cluster problem and also leads to correct bulk quantities for small cluster sizes. We illustrate the method by investigating the Fermi surface of a two-dimensional alloy. Dramatically, we find a smeared electronic topological transition not predicted by the conventional CPA.Comment: 17 pages, 5 figures, Submitted to: J. Phys.: Condens. Matter Editorial receipt 25 May 200

    The Double Quasar Q2138-431: Lensing by a Dark Galaxy?

    Get PDF
    We report the discovery of a new gravitational lens candidate Q2138-431AB, comprising two quasar images at a redshift of 1.641 separated by 4.5 arcsecs. The spectra of the two images are very similar, and the redshifts agree to better than 115 km.sec−1^{-1}. The two images have magnitudes BJ=19.8B_J = 19.8 and BJ=21.0B_J = 21.0, and in spite of a deep search and image subtraction procedure, no lensing galaxy has been found with R<23.8R < 23.8. Modelling of the system configuration implies that the mass-to-light ratio of any lensing galaxy is likely to be around 1000M⊙/L⊙1000 M_{\odot}/L_{\odot}, with an absolute lower limit of 200M⊙/L⊙200 M_{\odot}/L_{\odot} for an Einstein-de Sitter universe. We conclude that the most likely explanation of the observations is gravitational lensing by a dark galaxy, although it is possible we are seeing a binary quasar.Comment: 17 pages (Latex), 8 postscript figures included, accepted by MNRA

    The optically-powerful quasar E1821+643 is associated with a 300-kpc scale FRI radio structure

    Get PDF
    We present a deep image of the optically-powerful quasar E1821+643 at 18cm made with the Very Large Array (VLA). This image reveals radio emission, over 280 kpc in extent, elongated way beyond the quasar's host galaxy. Its radio structure has decreasing surface brightness with increasing distance from the bright core, characteristic of FRI sources (Fanaroff & Riley 1974). Its radio luminosity at 5GHz falls in the classification for `radio-quiet' quasars (it is only 10^23.9 W/Hz/sr; see e.g. Kellermann et al 1994). Its radio luminosity at 151MHz (which is 10^25.3 W/Hz/sr) is at the transition luminosity observed to separate FRIs and FRIIs. Hitherto, no optically-powerful quasar had been found to have a conventional FRI radio structure. For searches at low-frequency this is unsurprising given current sensitivity and plausible radio spectral indices for radio-quiet quasars. We demonstrate the inevitability of the extent of any FRqI radio structures being seriously under-estimated by existing targetted follow-up observations of other optically-selected quasars, which are typically short exposures of z > 0.3 objects, and discuss the implications for the purported radio bimodality in quasars. The nature of the inner arcsec-scale jet in E1821+643, together with its large-scale radio structure, suggest that the jet-axis in this quasar is precessing (cf. Galactic jet sources such as SS433). A possible explanation for this is that its central engine is a binary whose black holes have yet to coalesce. The ubiquity of precession in `radio-quiet' quasars, perhaps as a means of reducing the observable radio luminosity expected in highly-accreting systems, remains to be established.Comment: Accepted by ApJ Letters; higher quality versions of figures available at http://www-astro.physics.ox.ac.uk/~km

    American Gastroenterological Association Institute Clinical Practice Update—Expert Review: Care of Patients Who Have Achieved a Sustained Virologic Response After Antiviral Therapy for Chronic Hepatitis C Infection

    Get PDF
    Chronic hepatitis C virus infection is well-recognized as a common blood-borne infection with global public health impact affecting 3 to 5 million persons in the United States and more than 170 million persons worldwide. Chronic hepatitis C virus infection is associated with significant morbidity and mortality due to complications of liver cirrhosis and hepatocellular carcinoma. Current therapies with all-oral direct-acting antiviral agents are associated with high rates of sustained virologic response (SVR), generally exceeding 90%. SVR is associated with a reduced risk of liver cirrhosis, hepatic decompensation, need for liver transplantation, and both liver-related and all-cause mortality. However, a subset of patients who achieve SVR will remain at long-term risk for progression to cirrhosis, liver failure, hepatocellular carcinoma, and liver-related mortality. Limited evidence is available to guide clinicians on which post-SVR patients should be monitored vs discharged, how to monitor and with which tests, how frequently should monitoring occur, and for how long. In this clinical practice update, available evidence and expert opinion are used to generate best practice recommendations on the care of patients with chronic hepatitis C virus who have achieved SVR
    • 

    corecore