30 research outputs found

    Five-year outcome in 18 010 patients from the German Aortic Valve Registry

    Get PDF
    OBJECTIVES: To determine the 5-year outcome in patients treated by isolated transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (sAVR)—a prospective observational cohort study. METHODS: A total of 18 010 patients were included (n = 8942 TAVI and n = 9068 sAVR) in the German Aortic Valve Registry (GARY) who were treated in 2011 and 2012 at 92 sites in central Germany. Eligible patients with TAVI and sAVR were matched using propensity scores in a nearest-neighbour approach. Patients with repeat procedures or unequivocal indication for one treatment option (e.g. frailty) were excluded (n = 4785 for TAVI and n = 2 for sAVR). This led to 13 223 patients (4157 TAVI and 9066 sAVR) as an unmatched subcohort. The main outcome measure was the 5-year all-cause mortality. RESULTS: TAVI patients were significantly older (80.9 ± 6.1 vs 68.5 ± 11.1 years, P < 0.001), had a higher Society of Thoracic Surgeons (STS) score (6.3 ± 4.9 vs 2.6 ± 3.0, P < 0.001) and a higher 5-year all-cause mortality (49.8% vs 16.5%, P < 0.0001). There was no major difference in in-hospital stroke, in-hospital myocardial infarction, or temporary and chronic dialysis. In the propensity score-matched group (n = 3640), there were 763 deaths (41.9%) among 1820 TAVI patients compared with 552 (30.3%) among 1820 treated with sAVR during the 5-year follow-up (hazard ratio 1.51, 95% confidence interval 1.35–1.68; P < 0.0001). New pacemaker implantation was performed in 448 patients (24.6%) after TAVI and in 201 (11.0%) after sAVR (P < 0.0001). CONCLUSIONS: The 5-year follow-up data show that TAVI patients were significantly older and had a higher STS score than sAVR patients. After propensity score matching, TAVI with early-generation prosthesis was associated with significantly higher 5-year all-cause mortality than sAVR

    Integration of radiation oncology teaching in medical studies by German medical faculties due to the new licensing regulations: an overview and recommendations of the consortium academic radiation oncology of the German Society for Radiation Oncology (DEGRO)

    Get PDF
    The new Medical Licensing Regulations 2025 (Ärztliche Approbationsordnung, ÄApprO) will soon be passed by the Federal Council (Bundesrat) and will be implemented step by step by the individual faculties in the coming months. The further development of medical studies essentially involves an orientation from fact-based to competence-based learning and focuses on practical, longitudinal and interdisciplinary training. Radiation oncology and radiation therapy are important components of therapeutic oncology and are of great importance for public health, both clinically and epidemiologically, and therefore should be given appropriate attention in medical education. This report is based on a recent survey on the current state of radiation therapy teaching at university hospitals in Germany as well as the contents of the National Competence Based Learning Objectives Catalogue for Medicine 2.0 (Nationaler Kompetenzbasierter Lernzielkatalog Medizin 2.0, NKLM) and the closely related Subject Catalogue (Gegenstandskatalog, GK) of the Institute for Medical and Pharmaceutical Examination Questions (Institut für Medizinische und Pharmazeutische Prüfungsfragen, IMPP). The current recommendations of the German Society for Radiation Oncology (Deutsche Gesellschaft für Radioonkologie, DEGRO) regarding topics, scope and rationale for the establishment of radiation oncology teaching at the respective faculties are also included

    MitraClip after failed surgical mitral valve repair: an international multicenter study

    Get PDF
    BackgroundRecurrence of mitral regurgitation (MR) after surgical mitral valve repair (SMVR) varies and may require reoperation. Redo mitral valve surgery can be technically challenging and is associated with increased risk of mortality and morbidity. We aimed to assess the feasibility and safety of MitraClip as a treatment strategy after failed SMVR and identify procedure modifications to overcome technical challenges.Methods and ResultsThis international multicenter observational retrospective study collected information for all patients from 16 high-volume hospitals who were treated with MitraClip after failed SMVR from October 29, 2009, until August 1, 2017. Data were anonymously collected. Technical and device success were recorded per modified Mitral Valve Academic Research Consortium criteria. Overall, 104 consecutive patients were included. Median Society of Thoracic Surgeons score was 4.5% and median age was 73 years. At baseline, the majority of patients (82%) were in New York Heart Association class >= III and MR was moderate or higher in 86% of patients. The cause of MR pre-SMVR was degenerative in 50%, functional in 35%, mixed in 8%, and missing/unknown in 8% of patients. The median time between SMVR and MitraClip was 5.3 (1.9-9.7) years. Technical and device success were 90% and 89%, respectively. Additional/modified imaging was applied in 21% of cases. An MR reduction of >= 1 grade was achieved in 94% of patients and residual MR was moderate or less in 90% of patients. In-hospital all-cause mortality was 2%, and 86% of patients were in New York Heart Association class <= II.ConclusionsMitraClip is a safe and less invasive treatment option for patients with recurrent MR after failed SMVR. Additional/modified imaging may help overcome technical challenges during leaflet grasping.Cardiolog

    Status Update and Interim Results from the Asymptomatic Carotid Surgery Trial-2 (ACST-2)

    Get PDF
    Objectives: ACST-2 is currently the largest trial ever conducted to compare carotid artery stenting (CAS) with carotid endarterectomy (CEA) in patients with severe asymptomatic carotid stenosis requiring revascularization. Methods: Patients are entered into ACST-2 when revascularization is felt to be clearly indicated, when CEA and CAS are both possible, but where there is substantial uncertainty as to which is most appropriate. Trial surgeons and interventionalists are expected to use their usual techniques and CE-approved devices. We report baseline characteristics and blinded combined interim results for 30-day mortality and major morbidity for 986 patients in the ongoing trial up to September 2012. Results: A total of 986 patients (687 men, 299 women), mean age 68.7 years (SD ± 8.1) were randomized equally to CEA or CAS. Most (96%) had ipsilateral stenosis of 70-99% (median 80%) with contralateral stenoses of 50-99% in 30% and contralateral occlusion in 8%. Patients were on appropriate medical treatment. For 691 patients undergoing intervention with at least 1-month follow-up and Rankin scoring at 6 months for any stroke, the overall serious cardiovascular event rate of periprocedural (within 30 days) disabling stroke, fatal myocardial infarction, and death at 30 days was 1.0%. Conclusions: Early ACST-2 results suggest contemporary carotid intervention for asymptomatic stenosis has a low risk of serious morbidity and mortality, on par with other recent trials. The trial continues to recruit, to monitor periprocedural events and all types of stroke, aiming to randomize up to 5,000 patients to determine any differential outcomes between interventions. Clinical trial: ISRCTN21144362. © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved

    Second asymptomatic carotid surgery trial (ACST-2): a randomised comparison of carotid artery stenting versus carotid endarterectomy

    Get PDF
    Background: Among asymptomatic patients with severe carotid artery stenosis but no recent stroke or transient cerebral ischaemia, either carotid artery stenting (CAS) or carotid endarterectomy (CEA) can restore patency and reduce long-term stroke risks. However, from recent national registry data, each option causes about 1% procedural risk of disabling stroke or death. Comparison of their long-term protective effects requires large-scale randomised evidence. Methods: ACST-2 is an international multicentre randomised trial of CAS versus CEA among asymptomatic patients with severe stenosis thought to require intervention, interpreted with all other relevant trials. Patients were eligible if they had severe unilateral or bilateral carotid artery stenosis and both doctor and patient agreed that a carotid procedure should be undertaken, but they were substantially uncertain which one to choose. Patients were randomly allocated to CAS or CEA and followed up at 1 month and then annually, for a mean 5 years. Procedural events were those within 30 days of the intervention. Intention-to-treat analyses are provided. Analyses including procedural hazards use tabular methods. Analyses and meta-analyses of non-procedural strokes use Kaplan-Meier and log-rank methods. The trial is registered with the ISRCTN registry, ISRCTN21144362. Findings: Between Jan 15, 2008, and Dec 31, 2020, 3625 patients in 130 centres were randomly allocated, 1811 to CAS and 1814 to CEA, with good compliance, good medical therapy and a mean 5 years of follow-up. Overall, 1% had disabling stroke or death procedurally (15 allocated to CAS and 18 to CEA) and 2% had non-disabling procedural stroke (48 allocated to CAS and 29 to CEA). Kaplan-Meier estimates of 5-year non-procedural stroke were 2·5% in each group for fatal or disabling stroke, and 5·3% with CAS versus 4·5% with CEA for any stroke (rate ratio [RR] 1·16, 95% CI 0·86–1·57; p=0·33). Combining RRs for any non-procedural stroke in all CAS versus CEA trials, the RR was similar in symptomatic and asymptomatic patients (overall RR 1·11, 95% CI 0·91–1·32; p=0·21). Interpretation: Serious complications are similarly uncommon after competent CAS and CEA, and the long-term effects of these two carotid artery procedures on fatal or disabling stroke are comparable. Funding: UK Medical Research Council and Health Technology Assessment Programme

    Transcatheter Aortic Valve Replacement With the LOTUS Edge System: Early European Experience

    No full text
    Objectives: The aim of this study was to evaluate the short-term safety and efficacy of transcatheter aortic valve replacement (TAVR) with the LOTUS Edge system. Background: The LOTUS Edge system was commercially re-released in April 2019. The authors report the first European experience with this device. Methods: A multicenter, single-arm, retrospective registry was initiated to evaluate short-term clinical outcomes. Included cases are the first experience with this device and new implantation technique in Europe. Clinical, echocardiographic, and computed tomographic data were analyzed. Endpoints were defined according to Valve Academic Research Consortium-2 and were site reported. Results: Between April and November 2019, 286 consecutive patients undergoing TAVR with the LOTUS Edge system at 18 European centers were included. The mean age and Society of Thoracic Surgeons score were 81.2 ± 6.9 years and 5.2 ± 5.4%, respectively. Nearly one-half of all patients (47.9%) were considered to have complex anatomy. Thirty-day major adverse events included death (2.4% [n = 7]) and stroke (3.5% [n = 10]). After TAVR, the mean aortic valve area was 1.9 ± 0.9 cm2, and the mean transvalvular gradient was 11.9 ± 5.7 mm Hg. None or trace paravalvular leak (PVL) occurred in 84.4% and moderate PVL in 2.0%. There were no cases of severe PVL. New permanent pacemaker (PPM) implantation was required in 25.9% among all patients and 30.8% among PPM-naive patients. Conclusions: Early experience with the LOTUS Edge system demonstrated satisfactory short-term safety and efficacy, favorable hemodynamic data, and very low rates of PVL in an anatomically complex cohort. New PPM implantation remained high. Further study will evaluate if increasing operator experience with the device and new implantation technique can reduce the incidence of PPM implantation

    Integration of radiation oncology teaching in medical studies by German medical faculties due to the new licensing regulations: An overview and recommendations of the consortium academic radiation oncology of the German Society for Radiation Oncology (DEG

    Get PDF
    The new Medical Licensing Regulations 2025 (Ärztliche Approbationsordnung, ÄApprO) will soon be passed by the Federal Council (Bundesrat) and will be implemented step by step by the individual faculties in the coming months. The further development of medical studies essentially involves an orientation from fact-based to competence-based learning and focuses on practical, longitudinal and interdisciplinary training. Radiation oncology and radiation therapy are important components of therapeutic oncology and are of great importance for public health, both clinically and epidemiologically, and therefore should be given appropriate attention in medical education. This report is based on a&nbsp;recent survey on the current state of radiation therapy teaching at university hospitals in Germany as well as the contents of the National Competence Based Learning Objectives Catalogue for Medicine 2.0 (Nationaler Kompetenzbasierter Lernzielkatalog Medizin 2.0, NKLM) and the closely related Subject Catalogue (Gegenstandskatalog, GK) of the Institute for Medical and Pharmaceutical Examination Questions (Institut für Medizinische und Pharmazeutische Prüfungsfragen, IMPP). The current recommendations of the German Society for Radiation Oncology (Deutsche Gesellschaft für Radioonkologie, DEGRO) regarding topics, scope and rationale for the establishment of radiation oncology teaching at the respective faculties are also included
    corecore