85 research outputs found

    Trap States Ruling Photoconductive Gain in Tissue-Equivalent, Printed Organic X-Ray Detectors

    Get PDF
    Organic semiconductors are excellent candidates for X-ray detectors that can adapt to new applications, with unique properties including mechanical flexibility and the ability to cover large surfaces. Their chemical composition, primarily carbon and hydrogen, makes them human tissue equivalent in terms of radiation absorption. This is a highly desirable property for a radiation dosimeter to be employed in medical diagnostics and therapy, however a low-Z composition limits the absorption of ionizing radiation. The detection efficiency can be enhanced by considering the photoconductive gain (PG) effect, a significant contributor to the ionizing radiation detection mechanism in this class of materials. In this work, a process of controlled solution deposition by nozzle printing and crystallization of an organic semiconductor thin film is demonstrated whereby a flexible, arrayed thin-film X-ray detector with record X-ray sensitivities among flexible radiation detectors (S = (9.0 +/- 0.4) x 10(7) mu C Gy(-1) cm(-3)) is developed. The excitonic peaks responsible for the activation of the PG effect are investigated and identified using a novel technique called photocurrent spectroscopy optical quenching, and the analysis of the changes in trap states is further demonstrated

    Morphology and mobility as tools to control and unprecedentedly enhance X-ray sensitivity in organic thin-films

    Get PDF
    Organic semiconductor materials exhibit a great potential for the realization of large-area solution-processed devices able to directly detect high-energy radiation. However, only few works investigated on the mechanism of ionizing radiation detection in this class of materials, so far. In this work we investigate the physical processes behind X-ray photoconversion employing bis-(triisopropylsilylethynyl)-pentacene thin-films deposited by bar-assisted meniscus shearing. The thin film coating speed and the use of bis-(triisopropylsilylethynyl)-pentacene:polystyrene blends are explored as tools to control and enhance the detection capability of the devices, by tuning the thin-film morphology and the carrier mobility. The so-obtained detectors reach a record sensitivity of 1.3 \ub7 104 \ub5C/Gy\ub7cm2, the highest value reported for organic-based direct X-ray detectors and a very low minimum detectable dose rate of 35 \ub5Gy/s. Thus, the employment of organic large-area direct detectors for X-ray radiation in real-life applications can be foreseen

    Isolation and characterization of two newly established thymoma PDXs from two relapses of the same patient: a new tool to investigate thymic malignancies

    Get PDF
    BackgroundThymic malignancies are a heterogeneous group of rare cancers for which systemic chemotherapy is the standard treatment in the setting of advanced, recurrent or refractory diseases. Both environmental and genetic risk factors have not been fully clarified and few target-specific drugs have been developed for thymic epithelial tumors. A major challenge in studying thymic epithelial tumors is the lack of preclinical models for translational studies.Main bodyStarting from bioptic material of two consecutive recurrences of the same patient, we generated two patient-derived xenografts. The patient-derived xenografts models were characterized for histology by immunohistochemistry and mutations using next-generation sequencing. When compared to the original tumors resected from the patient, the two patient-derived xenografts had preserved morphology after the stain with hematoxylin and eosin, although there was a moderate degree of de-differentiation. From a molecular point of view, the two patient-derived xenografts maintained 74.3 and 61.8% of the mutations present in the human tumor of origin.Short conclusionThe newly generated patient-derived xenografts recapitulate both the molecular characteristics and the evolution of the thymoma it derives from well, allowing to address open questions for this rare cancer

    Cysteine oxidation targets peroxiredoxins 1 and 2 for exosomal release through a novel mechanism of redox-dependent secretion

    Get PDF
    Non-classical protein secretion is of major importance as a number of cytokines and inflammatory mediators are secreted via this route. Current evidence indicates that there are several mechanistically distinct methods of non-classical secretion. We have recently shown that peroxiredoxin (Prdx) 1 and Prdx2 are released by various cells upon exposure to inflammatory stimuli such as LPS or TNF-α. The released Prdx then acts to induce production of inflammatory cytokines. However, Prdx1 and 2 do not have signal peptides and therefore must be secreted by alternative mechanisms as has been postulated for the inflammatory mediators IL-1β and HMGB1. We show here that circulating Prdx1 and 2 are present exclusively as disulphide-linked homodimers. Inflammatory stimuli also induce in vitro release of Prdx1 and 2 as disulfide-linked homodimers. Mutation of cysteines Cys51 or Cys172 (but not Cys70) in Prdx2, and Cys52 or Cys173 (but not Cys71 or Cys83) in Prdx1 prevented dimer formation and this was associated with inhibition of their TNF-α-induced release. Thus, the presence and oxidation of key cysteine residues in these proteins are a prerequisite for their secretion in response to TNF-α and this release can be induced with an oxidant. In contrast, the secretion of the nuclear-associated danger signal HMGB1 is independent of cysteine oxidation, as shown by experiments with a cysteine-free HMGB1 mutant. Release of Prdx1 and 2 is not prevented by inhibitors of the classical secretory pathway; instead, both Prdx1 and 2 are released in exosomes from both HEK cells and monocytic cells. Serum Prdx1 and 2 are also associated with the exosomes. These results describe a novel pathway of protein secretion mediated by cysteine oxidation that underlines the importance of redox-dependent signalling mechanisms in inflammation

    Molecular weight tuning of organic semiconductors for curved organic–inorganic hybrid X‐ray detectors

    Get PDF
    Curved X-ray detectors have the potential to revolutionize diverse sectors due to benefits such as reduced image distortion and vignetting compared to their planar counterparts. While the use of inorganic semiconductors for curved detectors are restricted by their brittle nature, organic–inorganic hybrid semiconductors which incorporated bismuth oxide nanoparticles in an organic bulk heterojunction consisting of poly(3-hexylthiophene-2,5-diyl) (P3HT) and [6,6]-phenyl C71 butyric acid methyl ester (PC70BM) are considered to be more promising in this regard. However, the influence of the P3HT molecular weight on the mechanical stability of curved, thick X-ray detectors remains less well understood. Herein, high P3HT molecular weights (>40 kDa) are identified to allow increased intermolecular bonding and chain entanglements, resulting in X-ray detectors that can be curved to a radius as low as 1.3 mm with low deviation in X-ray response under 100 repeated bending cycles while maintaining an industry-standard dark current of <1 pA mm−2 and a sensitivity of ≈ 0.17 μC Gy−1 cm−2. This study identifies a crucial missing link in the development of curved detectors, namely the importance of the molecular weight of the polymer semiconductors used

    Prevalence, Outcome, and Prevention of Congenital Cytomegalovirus Infection in Neonates Born to Women With Preconception Immunity (CHILd Study)

    Get PDF
    Background. Human cytomegalovirus (HCMV) is the leading infectious cause of congenital disabilities. We designed a prospective study to investigate the rate, outcome, and risk factors of congenital CMV (cCMV) infection in neonates born to immune women, and the potential need and effectiveness of hygiene recommendations in this population.Methods. The study was composed of 2 sequential parts: an epidemiology (part 1) and a prevention (part 2) study. Performance of part 2 depended upon a cCMV rate >0.4%. Women enrolled in part 1 did not receive hygiene recommendations. Newborns were screened by HCMV DNA testing in saliva and cCMV was confirmed by urine testing.Results. Saliva swabs were positive for HCMV DNA in 45/9661 newborns and cCMV was confirmed in 18 cases. The rate of cCMV was .19% (95% confidence interval [CI]: .11-.29%), and 3 out of 18 infants with cCMV had symptoms of CMV at birth. Age, nationality, occupation, and contact with children were similar between mothers of infected and noninfected newborns. Twin pregnancy (odds ratio [OR]: 7.2; 95% CI: 1.7-32.2; P=.037) and maternal medical conditions (OR: 3.9; 95% CI: 1.5-10.1; P= .003) appeared associated with cCMV. Given the rate of cCMV was lower than expected, the prevention part of the study was cancelled.Conclusions. Newborns from women with preconception immunity have a low rate of cCMV, which appears to be mostly due to reactivation of the latent virus. Therefore, serological screening in childbearing age would be pivotal to identify HCMV-seropositive women, whose newborns have a low risk of cCMV

    Tissue equivalent curved organic x‐ray detectors utilizing high atomic number polythiophene analogues

    Get PDF
    Organic semiconductors are a promising material candidate for X-ray detection. However, the low atomic number (Z) of organic semiconductors leads to poor X-ray absorption thus restricting their performance. Herein, the authors propose a new strategy for achieving high-sensitivity performance for X-ray detectors based on organic semiconductors modified with high –Z heteroatoms. X-ray detectors are fabricated with p-type organic semiconductors containing selenium heteroatoms (poly(3-hexyl)selenophene (P3HSe)) in blends with an n-type fullerene derivative ([6,6]-Phenyl C71 butyric acid methyl ester (PC70BM). When characterized under 70, 100, 150, and 220 kVp X-ray radiation, these heteroatom-containing detectors displayed a superior performance in terms of sensitivity up to 600 ± 11 nC Gy−1 cm−2 with respect to the bismuth oxide (Bi2O3) nanoparticle (NP) sensitized organic detectors. Despite the lower Z of selenium compared to the NPs typically used, the authors identify a more efficient generation of electron-hole pairs, better charge transfer, and charge transport characteristics in heteroatom-incorporated detectors that result in this breakthrough detector performance. The authors also demonstrate flexible X-ray detectors that can be curved to a radius as low as 2 mm with low deviation in X-ray response under 100 repeated bending cycles while maintaining an industry-standard ultra-low dark current of 0.03 ± 0.01 pA mm−2

    Prevalence, Outcome, and Prevention of Congenital Cytomegalovirus Infection in Neonates Born to Women with Preconception Immunity (CHILd Study)

    Get PDF
    Background: Human cytomegalovirus (HCMV) is the leading infectious cause of congenital disabilities. We designed a prospective study to investigate the rate, outcome, and risk factors of congenital CMV (cCMV) infection in neonates born to immune women, and the potential need and effectiveness of hygiene recommendations in this population. Methods: The study was composed of 2 sequential parts: an epidemiology (part 1) and a prevention (part 2) study. Performance of part 2 depended upon a cCMV rate &gt;0.4%. Women enrolled in part 1 did not receive hygiene recommendations. Newborns were screened by HCMV DNA testing in saliva and cCMV was confirmed by urine testing. Results: Saliva swabs were positive for HCMV DNA in 45/9661 newborns and cCMV was confirmed in 18 cases. The rate of cCMV was. 19% (95% confidence interval [CI]:. 11-.29%), and 3 out of 18 infants with cCMV had symptoms of CMV at birth. Age, nationality, occupation, and contact with children were similar between mothers of infected and noninfected newborns. Twin pregnancy (odds ratio [OR]: 7.2; 95% CI: 1.7-32.2; P =. 037) and maternal medical conditions (OR: 3.9; 95% CI: 1.5-10.1; P =. 003) appeared associated with cCMV. Given the rate of cCMV was lower than expected, the prevention part of the study was cancelled. Conclusions: Newborns from women with preconception immunity have a low rate of cCMV, which appears to be mostly due to reactivation of the latent virus. Therefore, serological screening in childbearing age would be pivotal to identify HCMV-seropositive women, whose newborns have a low risk of cCMV. Clinical trials registration: www.clinicaltrials.gov (NCT03973359)

    Overexpression of IL-1ra gene up-regulates interleukin-1β converting enzyme (ICE) gene expression: possible mechanism underlying IL-1β-resistance of cancer cells

    Get PDF
    We investigated the interaction of endogenous interleukin (IL)-1β, IL-1ra, and interleukin-1β converting enzyme (ICE) in four human urological cancer cell lines, KU-19-19, KU-1, KU-2 and KU-19-20. Northern blot analysis showed that IL-1β gene was expressed in all cell lines. On the other hand, in KU-19-19 and KU-19-20, the gene expressions of both IL-1ra and ICE were suppressed. MTT assay revealed that IL-1β (10 ng ml−1) promoted cell growth in KU-19-19 and KU-19-20, while it inhibited in KU-1 and KU-2. An ICE inhibitor, Acetyl-Tyr-Val-Ala-Asp-CHO (YVAD-CHO) blocked IL-1β-induced growth inhibition in KU-1 and KU-2. Overexpression of the secretory type IL-1ra with adenovirus vector (AxIL-1ra) enhanced ICE gene expression, while exogenous IL-1ra (100 ng ml–1) did not enhance it. Furthermore, AxIL-1ra treatment promoted endogenous IL-1β secretion and induced significant growth inhibition and apoptotic cell death on KU-19-19 and KU-19-20. Treatment with either IL-1ra (100 ng ml−1), IL-1β antibody (100 μg ml−1), or YVAD-CHO blocked AxIL-1ra-induced cell death in KU-19-19 and KU-19-20. These results suggest that IL-1β-sensitivity depends on the level of ICE gene expression, which is regulated by the level of endogenous sIL-1ra expression. This is a first report on the intracellular function of sIL-1ra and these findings may provide key insights into the mechanism underlying the viability of cancer cells. © 1999 Cancer Research Campaig
    corecore