2,613 research outputs found

    Publication and patent analysis of European researchers in the field of production technology and manufacturing systems

    Get PDF
    This paper develops a structured comparison among a sample of European researchers in the field of Production Technology and Manufacturing Systems, on the basis of scientific publications and patents. Researchers are evaluated and compared by a variegated set of indicators concerning (1) the output of individual researchers and (2) that of groups of researchers from the same country. While not claiming to be exhaustive, the results of this preliminary study provide a rough indication of the publishing and patenting activity of researchers in the field of interest, identifying (dis)similarities between different countries. Of particular interest is a proposal for aggregating analysis results by means of maps based on publication and patent indicators. A large amount of empirical data are presented and discusse

    Proposals for evaluating the regularity of a scientist'sresearch output

    No full text
    Evaluating the career of individual scientists according to their scientific output is a common bibliometric problem. Two aspects are classically taken into account: overall productivity and overall diffusion/impact, which can be measured by a plethora of indicators that consider publications and/or citations separately or synthesise these two quantities into a single number (e.g. h-index). A secondary aspect, which is sometimes mentioned in the rules of competitive examinations for research position/promotion, is time regularity of one researcher's scientific output. Despite the fact that it is sometimes invoked, a clear definition of regularity is still lacking. We define it as the ability of generating an active and stable research output over time, in terms of both publications/ quantity and citations/diffusion. The goal of this paper is introducing three analysis tools to perform qualitative/quantitative evaluations on the regularity of one scientist's output in a simple and organic way. These tools are respectively (1) the PY/CY diagram, (2) the publication/citation Ferrers diagram and (3) a simplified procedure for comparing the research output of several scientists according to their publication and citation temporal distributions (Borda's ranking). Description of these tools is supported by several examples

    MScMS-II: an innovative IR-based indoor coordinate measuring system for large-scale metrology applications

    No full text
    According to the current great interest concerning large-scale metrology applications in many different fields of manufacturing industry, technologies and techniques for dimensional measurement have recently shown a substantial improvement. Ease-of-use, logistic and economic issues, as well as metrological performance are assuming a more and more important role among system requirements. This paper describes the architecture and the working principles of a novel infrared (IR) optical-based system, designed to perform low-cost and easy indoor coordinate measurements of large-size objects. The system consists of a distributed network-based layout, whose modularity allows fitting differently sized and shaped working volumes by adequately increasing the number of sensing units. Differently from existing spatially distributed metrological instruments, the remote sensor devices are intended to provide embedded data elaboration capabilities, in order to share the overall computational load. The overall system functionalities, including distributed layout configuration, network self-calibration, 3D point localization, and measurement data elaboration, are discussed. A preliminary metrological characterization of system performance, based on experimental testing, is also presente

    A narrative review of individualized treatments of genitourinary tumors: Is the future brighter with molecular evaluations?

    Get PDF
    Few molecular prognostic and predictive biomarkers have been identified so far in genitourinary tumors. We started from a literature search to explore the status of the art of molecular pathology tests as diagnostic, prognostic, predictive biomarkers in genitourinary cancers. Next generation sequencing approaches now provide mind-changing information in the fields of kidney cancer diagnosis, predictive oncology of urothelial cancer, understanding the causes of testicular and penile cancer, and the comprehension of the drivers of prostate cancer progression beyond androgen regulation. The classification of kidney cancer will be based soon on molecular changes. The causes of non-HPV related penile cancer are largely unknown. The emerging high incidence of testicular cancer could be explained only on the basis of molecular changes. The response to novel therapeutic agents in prostatic and urothelial cancer will require thorough molecular tumor characterization. The hereditary risk of patients with early onset prostate cancer and their potential treatment with targeted therapy requires germline and somatic genetic assays. The implementation of effective biomarkers for the response to immune check-point inhibitors in genitourinary cancer is based on the assessment of inflammatory expression profiles and the tumor mutational burden. This review deals with the current tests and provides a tentative foresee of the future molecular biomarkers of genitourinary cancer

    The detection and photometric redshift determination of distant galaxies using SIRTF's Infrared Array Camera

    Get PDF
    We investigate the ability of the Space Infrared Telescope Facility's Infrared Array Camera to detect distant (z ~ 3)galaxies and measure their photometric redshifts. Our analysis shows that changing the original long wavelength filter specifications provides significant improvements in performance in this and other areas.Comment: 28 pages incl 12 figures; to appear in June 1999 PASP. Fig.12 replaced with corrected versio

    Upper Limits on the Extragalactic Background Light from the Gamma-Ray Spectra of Blazars

    Full text link
    The direct measurement of the extragalactic background light (EBL) is difficult at optical to infrared wavelengths because of the strong foreground radiation originating in the Solar System. Very high energy (VHE, E>>100 GeV) gamma rays interact with EBL photons of these wavelengths through pair production. In this work, the available VHE spectra from six blazars are used to place upper limits on the EBL. These blazars have been detected over a range of redshifts and a steepening of the spectral index is observed with increasing source distance. This can be interpreted as absorption by the EBL. In general, knowledge of the intrinsic source spectrum is necessary to determine the density of the intervening EBL. Motivated by the observed spectral steepening with redshift, upper limits on the EBL are derived by assuming that the intrinsic spectra of the six blazars are E1.8\propto E^{-1.8}. Upper limits are then placed on the EBL flux at discrete energies without assuming a specific spectral shape for the EBL. This is an advantage over other methods since the EBL spectrum is uncertain.Comment: 33 pages, 14 figures, accepted by Ap

    Risk of de‐novo formation of chlormequat and mepiquat in industrial cocoa products assessed by ion chromatography coupled with high‐resolution mass spectrometry

    Get PDF
    Mepiquat (MQ) and chlormequat (CQ) are two main food contaminants that could be naturally present in various animal and plant foods due to heat treatments. Cocoa and its derivative products seem to be a matrix inclined, for both chemical characteristics and production technologies, to the formation of MQ and CQ. In this study, exploiting the selectivity and sensitivity of IC-HRMS, a new reliable analytical method was developed and validated for MQ and CQ quantification. The LOD of the method was set at 1.9 lg kg 1 for both CQ and MQ, and the linearity was defined from 6.25 to 625 lg kg 1 . Average recoveries, at 2 lg L 1 , were 96.5% and 97.5% for CQ and MQ, respectively, while precision as repeatability (RSDr%) was 2.3% and 5.1% respectively. Subsequently, a laboratory-scale experiment was conducted to assess, for the first time, the actual risk of MQ and CQ formation, confirming in cocoa products the presence of MQ at detectable concentration after 55 min at 180 °C, approximately 8 lg kg 1 for cocoa and 7 lg kg 1 for chips. However, the investigation of a wide variety of commercial cocoa and nuts products has fortunately ruled out the presence of such contaminants at detectable concentration

    Lapex: A Phoswich balloon experiment for hard X-ray astronomy

    Get PDF
    Satellite and balloon observations have shown that several classes of celestial objects are hard ( 15 keV) energy band with a sensitivity of approx 10 mCrab has been performed with the UCSD/MIT instrument (A4) on board the HEAO 1 satellite. About 70 X-ray sources were detected, including galactic and extragalactic objects. Hard X-ray emission has been detected in the Galaxy from X-ray pulsars. Extragalactic sources of hard X-ray emission include clusters of galaxies, QSOs, BL Lac objects, Seyfert galaxies. The essential characteristics of the Large Area Phoswich Experiment (LAPEX) for crowded sky field observations are described. It has: (1) a broad energy band of operation (20-300 keV); (2) a 3 sigma sensitivity of about 1 mCrab in 10,000 s of live observing time; and (3) imaging capabilities with an angular resolution of about 20'
    corecore