80 research outputs found

    Comparison of accuracy of fibrosis degree classifications by liver biopsy and non-invasive tests in chronic hepatitis C

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Non-invasive tests have been constructed and evaluated mainly for binary diagnoses such as significant fibrosis. Recently, detailed fibrosis classifications for several non-invasive tests have been developed, but their accuracy has not been thoroughly evaluated in comparison to liver biopsy, especially in clinical practice and for Fibroscan. Therefore, the main aim of the present study was to evaluate the accuracy of detailed fibrosis classifications available for non-invasive tests and liver biopsy. The secondary aim was to validate these accuracies in independent populations.</p> <p>Methods</p> <p>Four HCV populations provided 2,068 patients with liver biopsy, four different pathologist skill-levels and non-invasive tests. Results were expressed as percentages of correctly classified patients.</p> <p>Results</p> <p>In population #1 including 205 patients and comparing liver biopsy (reference: consensus reading by two experts) and blood tests, Metavir fibrosis (F<sub>M</sub>) stage accuracy was 64.4% in local pathologists vs. 82.2% (p < 10<sup>-3</sup>) in single expert pathologist. Significant discrepancy (≄ 2F<sub>M </sub>vs reference histological result) rates were: Fibrotest: 17.2%, FibroMeter<sup>2G</sup>: 5.6%, local pathologists: 4.9%, FibroMeter<sup>3G</sup>: 0.5%, expert pathologist: 0% (p < 10<sup>-3</sup>). In population #2 including 1,056 patients and comparing blood tests, the discrepancy scores, taking into account the error magnitude, of detailed fibrosis classification were significantly different between FibroMeter<sup>2G </sup>(0.30 ± 0.55) and FibroMeter<sup>3G </sup>(0.14 ± 0.37, p < 10<sup>-3</sup>) or Fibrotest (0.84 ± 0.80, p < 10<sup>-3</sup>). In population #3 (and #4) including 458 (359) patients and comparing blood tests and Fibroscan, accuracies of detailed fibrosis classification were, respectively: Fibrotest: 42.5% (33.5%), Fibroscan: 64.9% (50.7%), FibroMeter<sup>2G</sup>: 68.7% (68.2%), FibroMeter<sup>3G</sup>: 77.1% (83.4%), p < 10<sup>-3 </sup>(p < 10<sup>-3</sup>). Significant discrepancy (≄ 2 F<sub>M</sub>) rates were, respectively: Fibrotest: 21.3% (22.2%), Fibroscan: 12.9% (12.3%), FibroMeter<sup>2G</sup>: 5.7% (6.0%), FibroMeter<sup>3G</sup>: 0.9% (0.9%), p < 10<sup>-3 </sup>(p < 10<sup>-3</sup>).</p> <p>Conclusions</p> <p>The accuracy in detailed fibrosis classification of the best-performing blood test outperforms liver biopsy read by a local pathologist, i.e., in clinical practice; however, the classification precision is apparently lesser. This detailed classification accuracy is much lower than that of significant fibrosis with Fibroscan and even Fibrotest but higher with FibroMeter<sup>3G</sup>. FibroMeter classification accuracy was significantly higher than those of other non-invasive tests. Finally, for hepatitis C evaluation in clinical practice, fibrosis degree can be evaluated using an accurate blood test.</p

    Lipid Nanocapsules Loaded with Rhenium-188 Reduce Tumor Progression in a Rat Hepatocellular Carcinoma Model

    Get PDF
    International audienceBACKGROUND: Due to their nanometric scale (50 nm) along with their biomimetic properties, lipid nanocapsules loaded with Rhenium-188 (LNC(188)Re-SSS) constitute a promising radiopharmaceutical carrier for hepatocellular carcinoma treatment as its size may improve tumor penetration in comparison with microspheres devices. This study was conducted to confirm the feasibility and to assess the efficacy of internal radiation with LNC(188)Re-SSS in a chemically induced hepatocellular carcinoma rat model. METHODOLOGY/PRINCIPAL FINDINGS: Animals were treated with an injection of LNC(188)Re-SSS (80 MBq or 120 MBq). The treated animals (80 MBq, n = 12; 120 MBq, n = 11) were compared with sham (n = 12), blank LNC (n = 7) and (188)Re-perrhenate (n = 4) animals. The evaluation criteria included rat survival, tumor volume assessment, and vascular endothelial growth factor quantification. Following treatment with LNC(188)Re-SSS (80 MBq) therapeutic efficiency was demonstrated by an increase in the median survival from 54 to 107% compared with control groups with up to 7 long-term survivors in the LNC(188)Re-SSS group. Decreased vascular endothelial growth factor expression in the treated rats could indicate alterations in the angiogenesis process. CONCLUSIONS/SIGNIFICANCE: Overall, these results demonstrate that internal radiation with LNC(188)Re-SSS is a promising new strategy for hepatocellular carcinoma treatment

    The GRAVITY+ Project: Towards All-sky, Faint-Science, High-Contrast Near-Infrared Interferometry at the VLTI

    Full text link
    The GRAVITY instrument has been revolutionary for near-infrared interferometry by pushing sensitivity and precision to previously unknown limits. With the upgrade of GRAVITY and the Very Large Telescope Interferometer (VLTI) in GRAVITY+, these limits will be pushed even further, with vastly improved sky coverage, as well as faint-science and high-contrast capabilities. This upgrade includes the implementation of wide-field off-axis fringe-tracking, new adaptive optics systems on all Unit Telescopes, and laser guide stars in an upgraded facility. GRAVITY+ will open up the sky to the measurement of black hole masses across cosmic time in hundreds of active galactic nuclei, use the faint stars in the Galactic centre to probe General Relativity, and enable the characterisation of dozens of young exoplanets to study their formation, bearing the promise of another scientific revolution to come at the VLTI.Comment: Published in the ESO Messenge

    Multiple star systems in the Orion nebula

    Get PDF
    This is the author accepted manuscript. The final fersion is available from EDP Sciences via the DOI in this record.This work presents an interferometric study of the massive-binary fraction in the Orion Trapezium cluster with the recently comissioned GRAVITY instrument. We observed a total of 16 stars of mainly OB spectral type. We find three previously unknown companions for ξ1 Ori B, ξ2 Ori B, and ξ2 Ori C. We determined a separation for the previously suspected companion of NU Ori. We confirm four companions for ξ1 Ori A, ξ1 Ori C, ξ1 Ori D, and ξ2 Ori A, all with substantially improved astrometry and photometric mass estimates. We refined the orbit of the eccentric high-mass binary ξ1 Ori C and we are able to derive a new orbit for ξ1 Ori D. We find a system mass of 21.7 M⊙ and a period of 53 days. Together with other previously detected companions seen in spectroscopy or direct imaging, eleven of the 16 high-mass stars are multiple systems. We obtain a total number of 22 companions with separations up to 600 AU. The companion fraction of the early B and O stars in our sample is about two, significantly higher than in earlier studies of mostly OB associations. The separation distribution hints toward a bimodality. Such a bimodality has been previously found in A stars, but rarely in OB binaries, which up to this point have been assumed to be mostly compact with a tail of wider companions. We also do not find a substantial population of equal-mass binaries. The observed distribution of mass ratios declines steeply with mass, and like the direct star counts, indicates that our companions follow a standard power law initial mass function. Again, this is in contrast to earlier findings of flat mass ratio distributions in OB associations. We excluded collision as a dominant formation mechanism but find no clear preference for core accretion or competitive accretion.Marie SkƂodowska-Curie Grant AgreementFCT-PortugalERC Starting Gran

    MAORY for ELT: preliminary design overview

    Get PDF
    MAORY is one of the approved instruments for the European Extremely Large Telescope. It is an adaptive optics module, enabling high-angular resolution observations in the near infrared by real-time compensation of the wavefront distortions due to atmospheric turbulence and other disturbances such as wind action on the telescope. An overview of the instrument design is given in this paper

    The MAORY first-light adaptive optics module for E-ELT

    Get PDF
    The MAORY adaptive optics module is part of the first light instrumentation suite for the E-ELT. The MAORY project phase B is going to start soon. This paper contains a system-level overview of the current instrument design

    Valeur pronostique de l'hémodynamique et de la fibrose dans les hépatopathies chroniques

    No full text
    ANGERS-BU MĂ©decine-Pharmacie (490072105) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF

    Classe sociale : un terme fourre-tout ? : Fréquence et utilisations des termes liés à la stratification sociale dans deux revues (Sociologie du travail et la Revue française de sociologie).

    No full text
    Partant de la question du dĂ©sintĂ©rĂȘt supposĂ© du concept de "classes sociales" dans la littĂ©rature sociologique française (Ă  l'inverse des pays anglo-saxons), les auteurs ont dĂ©pouillĂ© deux revues majeures de la discipline : Sociologie du travail et la RFS, aux tournants des annĂ©es 70, 80 puis 90. Au final, le terme apparait un peu "fourre-tout", employĂ© soit comme synonyme de "groupe social", soit sans rĂ©fĂ©rence Ă  des cadres thĂ©oriques prĂ©cis. Il ne semble pas y avoir d'efforts entrepris en France pour une reconstruction thĂ©orique de la structure de la sociĂ©tĂ© en termes de "classes", "groupes sociaux" ou "strates". La sociologie française ne semble plus s'intĂ©resser qu'indirectement au thĂšme des classes sociales et de la stratification, privilĂ©giant, dans le sillage des PCS de l'INSEE un raisonnement fondĂ© sur l'agrĂ©gation de catĂ©gories socioprofessionnelles

    Current management of the complications of portal hypertension: variceal bleeding and ascites

    No full text
    Portal hypertension is one of the main consequences of cirrhosis. It results from a combination of increased intrahepatic vascular resistance and increased blood flow through the portal venous system. The condition leads to the formation of portosystemic collateral veins. Esophagogastric varices have the greatest clinical impact, with a risk of bleeding as high as 30% within 2 years of medium or large varices developing. Ascites, another important complication of advanced cirrhosis and severe portal hypertension, is sometimes refractory to treatment and is complicated by spontaneous bacterial peritonitis and hepatorenal syndrome. We describe the pathophysiology of portal hypertension and the current management of its complications, with emphasis on the prophylaxis and treatment of variceal bleeding and ascites
    • 

    corecore