13 research outputs found

    The effect of nanodiamonds on candida albicans adhesion and surface characteristics of PMMA denture base material : an in vitro study

    Get PDF
    Candida albicans is the main causative pathogen of denture stomatitis, which affects many complete denture patients. Objective: To evaluate the effect of different concentrations of nanodiamonds (NDs) added to polymethyl methacrylate (PMMA) denture base material on Candida albicans adhesion as well as on surface roughness and contact angle. Methodology: Acrylic resin specimens sized 10×10×3 mm3 were prepared and divided into four groups (n=30) according to ND concentration (0%, 0.5%, 1%, 1.5% by wt). Surface roughness was measured with a profilometer, and the contact angle with a goniometer. The effect of NDs on Candida albicans adhesion was evaluated using two methods: 1) slide count and 2) direct culture test. Analysis of variance (ANOVA) and Tukey's post hoc test were used in the statistical analyses. Results: Addition of NDs decreased the Candida albicans count significantly more than in the control group (p<0.05), with a lowest of 1% NDs. Addition of NDs also significantly decreased the surface roughness (p<0.05), but the contact angle remained the same. Incorporation of NDs into the PMMA denture base material effectively reduced Candida albicans adhesion and decreased surface roughness. Conclusion: PMMA/NDs composites could be valuable in the prevention of denture stomatitis, which is considered one of the most common clinical problems among removable denture wearers

    Influence of tooth loss on mandibular morphology: A cone-beam computed tomography study

    Get PDF
    Background: Tooth loss adversely affects patients’ health and psychosocial wellbeing. In addition, it changes mandibular morphology. Objective: To evaluate the effect of tooth loss, age, and gender on mandibular morphology. Materials and Methods: Cone-beam computed tomographic (CBCT) scans of 101 patients were examined to measure the gonial angle (GA), ramus height (RH) and condylar height (CH). Patients’ age, gender, and dental status were recorded. Repeated measures analysis of variance (ANOVA) was used to assess the impact of gender, age, and tooth loss on the GA, RH and CH. The mean measurements of the GA, RH and CH were compared between dentate/edentulous patients after splitting by gender. Results: The GA was larger in edentulous patients compared to dentate ones, in females than in males, and in older than in younger. RH on the right side was significantly longer than on the left side (P< 0.0001), and also longer in males and younger patients. CH was shorter in younger than in older patients and in dentate than in edentulous patients. Conclusions: Tooth loss is associated with changes in mandibular morphology and its prevention would avoid these irreversible changes.</p

    The effect of nanodiamonds on candida albicans adhesion and surface characteristics of PMMA denture base material - an in vitro study

    Get PDF
    Candida albicans is the main causative pathogen of denture stomatitis, which affects many complete denture patients. Objective: To evaluate the effect of different concentrations of nanodiamonds (NDs) added to polymethyl methacrylate (PMMA) denture base material on Candida albicans adhesion as well as on surface roughness and contact angle. Methodology: Acrylic resin specimens sized 10×10×3 mm3 were prepared and divided into four groups (n=30) according to ND concentration (0%, 0.5%, 1%, 1.5% by wt). Surface roughness was measured with a profilometer, and the contact angle with a goniometer. The effect of NDs on Candida albicans adhesion was evaluated using two methods: 1) slide count and 2) direct culture test. Analysis of variance (ANOVA) and Tukey’s post hoc test were used in the statistical analyses. Results: Addition of NDs decreased the Candida albicans count significantly more than in the control group (p<0.05), with a lowest of 1% NDs. Addition of NDs also significantly decreased the surface roughness (p<0.05), but the contact angle remained the same. Incorporation of NDs into the PMMA denture base material effectively reduced Candida albicans adhesion and decreased surface roughness. Conclusion: PMMA/NDs composites could be valuable in the prevention of denture stomatitis, which is considered one of the most common clinical problems among removable denture wearers.</p

    Impact of opioid-free analgesia on pain severity and patient satisfaction after discharge from surgery: multispecialty, prospective cohort study in 25 countries

    Get PDF
    Background: Balancing opioid stewardship and the need for adequate analgesia following discharge after surgery is challenging. This study aimed to compare the outcomes for patients discharged with opioid versus opioid-free analgesia after common surgical procedures.Methods: This international, multicentre, prospective cohort study collected data from patients undergoing common acute and elective general surgical, urological, gynaecological, and orthopaedic procedures. The primary outcomes were patient-reported time in severe pain measured on a numerical analogue scale from 0 to 100% and patient-reported satisfaction with pain relief during the first week following discharge. Data were collected by in-hospital chart review and patient telephone interview 1 week after discharge.Results: The study recruited 4273 patients from 144 centres in 25 countries; 1311 patients (30.7%) were prescribed opioid analgesia at discharge. Patients reported being in severe pain for 10 (i.q.r. 1-30)% of the first week after discharge and rated satisfaction with analgesia as 90 (i.q.r. 80-100) of 100. After adjustment for confounders, opioid analgesia on discharge was independently associated with increased pain severity (risk ratio 1.52, 95% c.i. 1.31 to 1.76; P &lt; 0.001) and re-presentation to healthcare providers owing to side-effects of medication (OR 2.38, 95% c.i. 1.36 to 4.17; P = 0.004), but not with satisfaction with analgesia (beta coefficient 0.92, 95% c.i. -1.52 to 3.36; P = 0.468) compared with opioid-free analgesia. Although opioid prescribing varied greatly between high-income and low- and middle-income countries, patient-reported outcomes did not.Conclusion: Opioid analgesia prescription on surgical discharge is associated with a higher risk of re-presentation owing to side-effects of medication and increased patient-reported pain, but not with changes in patient-reported satisfaction. Opioid-free discharge analgesia should be adopted routinely

    Effect of Patient’s Personality on Satisfaction with Their Present Complete Denture and after Increasing the Occlusal Vertical Dimension: A Study of Edentulous Egyptian Patients

    No full text
    Complete denture wearers often find it difficult to accept a new denture. Personality traits are among the factors that possibly affect patient satisfaction with a complete denture. Our aim was to investigate the influence of patients’ personality on satisfaction with their present denture and after an increase in the occlusal vertical dimension (OVD). Sixty edentulous patients with complete dentures (22 men and 38 women, mean age 66 years, and range 50–75 years) participated in the study. The age of their complete dentures ranged from 5 to 16 years. Patients’ personalities were evaluated using the Arabic version of the Eysenck Personality Questionnaire. Their satisfaction with their dentures before and after restoration of the OVD and relining of the mandibular denture was evaluated using two questionnaires (I and II), Patients with a high score of neuroticism were less satisfied with their original dentures and after relining and an increase of OVD compared with patients with an average score in that trait. The personality trait of psychoticism was significant to patients’ acceptance of an increase in OVD; that is, patients with a high score were less satisfied with their dentures after increase of OVD than patients with an average score. It is concluded that personality traits affect patients’ acceptance of their complete dentures

    Influence of CAD/CAM Milling and 3D-Printing Fabrication Methods on the Mechanical Properties of 3-Unit Interim Fixed Dental Prosthesis after Thermo-Mechanical Aging Process

    No full text
    This study assessed the influence of CAD/CAM milling and 3D-printing fabrication methods on mechanical properties of 3-unit interim fixed dental prosthesis (IFDPs) after thermo-mechanical aging. Forty 3-unit IFDPs were fabricated on a mandibular right second premolar and second molar of a typodont cast. Samples were fabricated from the following materials; auto-polymerized polymethyl methacrylate (conventional resin), CAD/CAM PMMA (milled resin) and two different CAD/CAM 3D-printed composite resins; digital light processing Asiga (DLP AS) and stereolithography NextDent (SLA ND). Mechanical properties were compared between the studied materials using Kruskal–Wallis test, followed by multiple pairwise comparisons using Bonferroni adjusted significance. There was a significant difference in flexural strength and microhardness between the studied materials (p p = 0.02). In conclusion, superior flexural strength, elastic modulus, and hardness were reported for milled IFDPs. SLA ND printed IFDPs showed comparable mechanical properties to milled ones except for the elastic modulus

    Do Morphological Changes in the Anterior Mandibular Region Interfere with Standard Implant Placement? A Cone Beam Computed Tomographic Cross-Sectional Study

    No full text
    Objective. To determine the morphological features in the anterior mandibular region, the presence of lingual foramen and canal dimensions in Saudi subjects that would interfere with standard implant placement. Methods. CBCT scans of patients seeking implant treatment were examined. Based on the dentition status, patients were categorized into edentulous (group I) and dentulous (group I). On the panoramic view, the distance between the two mental foramina was divided into vertical segments of 10 mm width. In each segment, vertical bone height and buccolingual thickness at three levels (alveolar crest, 5 mm, and 10 mm apical to the crest) were assessed. The lingual foramen prevalence and canal features were assessed as well. Comparisons between the two groups regarding the assessed parameters were performed using the t-test. The percentage of edentulous mandibles with thickness <6 mm corresponding to the standard implant diameter was also calculated. Results. Following the inclusion and exclusion criteria, group I consisted of 45 subjects and group II comprised 26 subjects. Bone height and thickness at the crestal level were significantly less in edentulous (I) than dentate mandibles (II) (P<0.0001). The lingual foramen was detected in 90% of patients. In both groups, males had significantly greater mandibular height than females (P=0.02 and 0.005). At the crestal level, the thickness was <6 mm in 50% of the anterior mandibular segments. Conclusion. Half of the edentulous patients may receive normal size implants in the anterior interforaminal segments, while the other half will be limited to narrow implants (3.5 mm and less). The lingual foramen location, canal size, and position may represent another limitation for implant placement in that segment

    PMMA denture base material enhancement:a review of fiber, filler, and nanofiller addition

    No full text
    Abstract This paper reviews acrylic denture base resin enhancement during the past few decades. Specific attention is given to the effect of fiber, filler, and nanofiller addition on poly(methyl methacrylate) (PMMA) properties. The review is based on scientific reviews, papers, and abstracts, as well as studies concerning the effect of additives, fibers, fillers, and reinforcement materials on PMMA, published between 1974 and 2016. Many studies have reported improvement of PMMA denture base material with the addition of fillers, fibers, nanofiller, and hybrid reinforcement. However, most of the studies were limited to in vitro investigations without bioactivity and clinical implications. Considering the findings of the review, there is no ideal denture base material, but the properties of PMMA could be improved with some modifications, especially with silanized nanoparticle addition and a hybrid reinforcement system

    Comparative Evaluation of TiO<sub>2</sub> Nanoparticle Addition and Postcuring Time on the Flexural Properties and Hardness of Additively Fabricated Denture Base Resins

    No full text
    Three-dimensionally (3D)-printed fabricated denture bases have shown inferior strength to conventional and subtractively fabricated ones. Several factors could significantly improve the strength of 3D-printed denture base resin, including the addition of nanoparticles and post-curing factors. This study evaluated the effect of TiO2 nanoparticle (TNP) addition and the post-curing time (PCT) on the flexural properties and hardness of three-dimensionally (3D)-printed denture base resins. A total of 360 specimens were fabricated, with 180 specimens from each type of resin. For evaluating the flexural properties, bar-shaped specimens measuring 64 × 10 × 3.3 mm were used, while, for the hardness testing, disc-shaped specimens measuring 15 × 2 mm were employed. The two 3D-printed resins utilized in this study were Asiga (DentaBASE) and NextDent (Vertex Dental B.V). Each resin was modified by adding TNPs at 1% and 2% concentrations, forming two groups and an additional unmodified group. Each group was divided into three subgroups according to the PCT (15, 60, and 90 min). All the specimens were subjected to artificial aging (5000 cycles), followed by testing of the flexural strength and elastic modulus using a universal testing machine, and the hardness using the Vickers hardness test. A three-way ANOVA was used for the data analysis, and a post hoc Tukey’s test was used for the pairwise comparisons (α = 0.05). Scanning electron microscopy (SEM) was used for the fracture surface analysis. The addition of the TNPs increased the flexural strength in comparison to the unmodified groups (p p p p < 0.001). Both concentrations of the TNPs increased the flexural strength, while the 2% TNP concentration decreased the elastic modulus and hardness of the 3D-printed nanocomposites. The flexural strength and hardness increased as the PCT increased. The material type, TNP concentration, and PCT are important factors that affect the strength of 3D-printed nanocomposites and could improve their mechanical performance

    Effect of Low Nanodiamond Concentrations and Polymerization Techniques on Physical Properties and Antifungal Activities of Denture Base Resin

    No full text
    Background: Denture base resin has some drawbacks. This study investigated the impact of nanodiamonds (ND) and autoclave polymerization on the surface characteristics, translucency, and Candida albicans adherence in polymethyl methacrylate (PMMA) denture base resin after thermocycling. Methods: Heat-polymerized PMMA discs (15 &times; 2 mm) with a total sample size n = 160 were studied. Specimens were categorized into two main groups (N = 80): conventional water-bath-polymerized PMMA (CP/PMMA) and autoclave-polymerized PMMA (AP/PMMA). Each group was subdivided according to the ND concentration into four groups (n = 20): unmodified PMMA as a control, and 0.1%, 0.25%, and 0.5% ND&ndash;PMMA. Scanning electron microscopy (SEM) was used to inspect the morphology of the ND and the ND&ndash;PMMA mixtures before heat polymerization. The specimens were exposed to thermal cycling (5000 cycles at 5 and 55 &deg;C), then surface roughness was measured with a non-contact optical interferometric profilometer, contact angle with an automated goniometer, and translucency using a spectrophotometer. Colony-forming units (CFU) were used to determine the adherence of Candida albicans cells to the specimens. ANOVA and Tukey post hoc tests for pairwise comparison were utilized for the statistical analysis (&alpha; = 0.05). Results: Surface roughness was significantly reduced with ND addition to CP/PMMA (p &#706; 0.001), while the reduction was not statistically significant in AP/PMMA (p = 0.831). The addition of ND significantly reduced the contact angle, translucency, and Candida albicans count of CP/PMMA and AP/PMMA (p &#706; 0.001). The incorporation of ND in conjunction with autoclave polymerization of PMMA showed significant reduction in all tested properties (surface roughness, contact angle and Candida albicans adherence) except translucency (p = 0.726). Conclusions: ND addition to PMMA and autoclave polymerization improved the surface properties with respect to antifungal activities, while the translucency was adversely affected
    corecore