141 research outputs found

    New high-sensitivity, milliarcsecond resolution results from routine observations of lunar occultations at the ESO VLT

    Full text link
    (Abridged) Lunar occultations (LO) are a very efficient and powerful technique, that achieves the best combination of high angular resolution and sensitivity possible today at near-infrared wavelengths. Given that the events are fixed in time, that the sources are occulted randomly, and that the telescope use is minimal, the technique is very well suited for service mode observations. We have established a program of routine LO observations at the VLT observatory, especially designed to take advantage of short breaks available in-between other programs. We have used the ISAAC instrument in burst mode, capable of producing continuous read-outs at millisecond rates on a suitable subwindow. Given the random nature of the source selection, our aim has been primarily the investigation of a large number of stellar sources at the highest angular resolution in order to detect new binaries. Serendipitous results such as resolved sources and detection of circumstellar components were also anticipated. We have recorded the signal from background stars for a few seconds, around the predicted time of occultation by the Moon's dark limb. At millisecond time resolution, a characteristic diffraction pattern can be observed. Patterns for two or more sources superimpose linearly, and this property is used for the detection of binary stars. The detailed analysis of the diffraction fringes can be used to measure specific properties such as the stellar angular size and the presence of extended light sources such as a circumstellar shell. We present a list of 191 stars for which LO data could be recorded and analyzed. Results include the detection of 16 binary and 2 triple stars, all but one of which were previously unknown. The projected angular separations are as small as 4 milliarcseconds and magnitude differences as high as ?K=5.8 mag...Comment: 10 pages, 3 figures, to be published in A&

    Results and recommendations from an intercomparison of six Hygroscopicity-TDMA systems

    Get PDF
    The performance of six custom-built Hygrocopicity-Tandem Differential Mobility Analyser (H-TDMA) systems was investigated in the frame of an international calibration and intercomparison workshop held in Leipzig, February 2006. The goal of the workshop was to harmonise H-TDMA measurements and develop recommendations for atmospheric measurements and their data evaluation. The H-TDMA systems were compared in terms of the sizing of dry particles, relative humidity (RH) uncertainty, and consistency in determination of number fractions of different hygroscopic particle groups. The experiments were performed in an air-conditioned laboratory using ammonium sulphate particles or an external mixture of ammonium sulphate and soot particles. The sizing of dry particles of the six H-TDMA systems was within 0.2 to 4.2% of the selected particle diameter depending on investigated size and individual system. Measurements of ammonium sulphate aerosol found deviations equivalent to 4.5% RH from the set point of 90% RH compared to results from previous experiments in the literature. Evaluation of the number fraction of particles within the clearly separated growth factor modes of a laboratory generated externally mixed aerosol was done. The data from the H-TDMAs was analysed with a single fitting routine to investigate differences caused by the different data evaluation procedures used for each H-TDMA. The differences between the H-TDMAs were reduced from +12/-13% to +8/-6% when the same analysis routine was applied. We conclude that a common data evaluation procedure to determine number fractions of externally mixed aerosols will improve the comparability of H-TDMA measurements. It is recommended to ensure proper calibration of all flow, temperature and RH sensors in the systems. It is most important to thermally insulate the aerosol humidification unit and the second DMA and to monitor these temperatures to an accuracy of 0.2 degrees C. For the correct determination of external mixtures, it is necessary to take into account size-dependent losses due to diffusion in the plumbing between the DMAs and in the aerosol humidification unit.Peer reviewe

    Milliarcsecond angular resolution of reddened stellar sources in the vicinity of the Galactic Center

    Full text link
    For the first time, the lunar occultation technique has been employed on a very large telescope in the near-IR with the aim of achieving systematically milliarcsecond resolution on stellar sources. We have demonstrated the burst mode of the ISAAC instrument, using a fast read-out on a small area of the detector to record many tens of seconds of data at a time on fields of few squared arcsec. We have used the opportunity to record a large number of LO events during a passage of the Moon close to the Galactic Center in March 2006. We have developed a data pipeline for the treatment of LO data, including the automated estimation of the main data analysis parameters using a wavelet-based method, and the preliminary fitting and plotting of all light curves. We recorded 51 LO events over about four hours. Of these, 30 resulted of sufficient quality to enable a detailed fitting. We detected two binaries with subarcsec projected separation and three stars with a marginally resolved angular diameter of about 2 mas. Two more SiO masers, were found to be resolved and in one case we could recover the brightness profile of the extended emission, which is well consistent with an optically thin shell. The remaining unresolved stars were used to characterize the performance of the method. The LO technique at a very large telescope is a powerful and efficient method to achieve angular resolution, sensitivity, and dynamic range that are among the best possible today with any technique. The selection of targets is naturally limited and LOs are fixed-time events, however each observation requires only a few minutes including overheads. As such, LOs are ideally suited to fill small gaps of idle time between standard observations.Comment: A&A in pres

    TFAW survey II: 6 Newly Validated Planets and 13 Planet Candidates from K2

    Full text link
    Searching for Earth-sized planets in data from Kepler's extended mission (K2) is a niche that still remains to be fully exploited. The TFAW survey is an ongoing project that aims to re-analyze all light curves in K2 C1-C8 and C12-C18 campaigns with a wavelet-based detrending and denoising method, and the period search algorithm TLS to search for new transit candidates not detected in previous works. We have analyzed a first subset of 24 candidate planetary systems around relatively faint host stars (10.9 < KpK_{p} < 15.4) to allow for follow-up speckle imaging observations. Using VESPA and TRICERATOPS, we statistically validate six candidates orbiting four unique host stars by obtaining false-positive probabilities smaller than 1% with both methods. We also present 13 vetted planet candidates that might benefit from other, more precise follow-up observations. All of these planets are sub-Neptune-sized, with two validated planets and three candidates with sub-Earth sizes, and have orbital periods between 0.81 and 23.98 days. Some interesting systems include two ultra-short-period planets, three multi-planetary systems, three sub-Neptunes that appear to be within the small planet Radius Gap, and two validated and one candidate sub-Earths (EPIC 210706310, EPIC 210768568, and EPIC 246078343) orbiting metal-poor stars.Comment: Submitted to Monthly Notices of the Royal Astronomical Society. 25 pages, 14 figure

    The First Naked-eye Superflare Detected from Proxima Centauri

    Full text link
    Proxima b is a terrestrial-mass planet in the habitable zone of Proxima Centauri. Proxima Centauri's high stellar activity, however, casts doubt on the habitability of Proxima b: sufficiently bright and frequent flares and any associated proton events may destroy the planet's ozone layer, allowing lethal levels of UV flux to reach its surface. In 2016 March, the Evryscope observed the first naked-eye-brightness superflare detected from Proxima Centauri. Proxima increased in optical flux by a factor of ∌68 during the superflare and released a bolometric energy of 1033.5 erg, ∌10× larger than any previously detected flare from Proxima. Over the last two years the Evryscope has recorded 23 other large Proxima flares ranging in bolometric energy from 1030.6 to 1032.4 erg; coupling those rates with the single superflare detection, we predict that at least five superflares occur each year. Simultaneous high-resolution High Accuracy Radial velocity Planet Searcher (HARPS) spectroscopy during the Evryscope superflare constrains the superflare's UV spectrum and any associated coronal mass ejections. We use these results and the Evryscope flare rates to model the photochemical effects of NOx atmospheric species generated by particle events from this extreme stellar activity, and show that the repeated flaring may be sufficient to reduce the ozone of an Earth-like atmosphere by 90% within five years; complete depletion may occur within several hundred kyr. The UV light produced by the Evryscope superflare would therefore have reached the surface with ∌100× the intensity required to kill simple UV-hardy microorganisms, suggesting that life would have to undergo extreme adaptations to survive in the surface areas of Proxima b exposed to these flares

    LS 5039: a runaway microquasar ejected from the galactic plane

    Get PDF
    We have compiled optical and radio astrometric data of the microquasar LS 5039 and derived its proper motion. This, together with the distance and radial velocity of the system, allows us to state that this source is escaping from its own regional standard of rest, with a total systemic velocity of about 150 km/s and a component perpendicular to the galactic plane larger than 100 km/s. This is probably the result of an acceleration obtained during the supernova event that created the compact object in this binary system. We have computed the trajectory of LS 5039 in the past, and searched for OB associations and supernova remnants in its path. In particular, we have studied the possible association between LS 5039 and the supernova remnant G016.8-01.1, which, despite our efforts, remains dubious. We have also discovered and studied an HI cavity in the ISM, which could have been created by the stellar wind of LS 5039 or by the progenitor of the compact object in the system. Finally, in the symmetric supernova explosion scenario, we estimate that at least 17 solar masses were lost in order to produce the high eccentricity observed. Such a mass loss could also explain the observed runaway velocity of the microquasar.Comment: 12 pages, 5 figures, LaTeX, uses aa.cls. Accepted for publication in A&

    Cytocompatibility of Medical Biomaterials Containing Nickel by Osteoblasts: a Systematic Literature Review

    Get PDF
    The present review is based on a survey of 21 studies on the cytocompatibility of medical biomaterials containing nickel, as assessed by cell culture of human and animal osteoblasts or osteoblast-like cells. Among the biomaterials evaluated were stainless steel, NiTi alloys, pure Ni, Ti, and other pure metals. The materials were either commercially available, prepared by the authors, or implanted by various techniques to generate a protective layer of oxides, nitrides, acetylides. The observation that the layers significantly reduced the initial release of metal ions and increased cytocompatibility was confirmed in cell culture experiments. Physical and chemical characterization of the materials was performed. This included, e.g., surface characterization (roughness, wettability, corrosion behavior, quantity of released ions, microhardness, and characterization of passivation layer). Cytocompatibility tests of the materials were conducted in the cultures of human or animal osteoblasts and osteoblast-like cells. The following assays were carried out: cell proliferation and viability test, adhesion test, morphology (by fluorescent microscopy or SEM). Also phenotypic and genotypic markers were investigated. In the majority of works, it was found that the most cytocompatible materials were stainless steel and NiTi alloy. Pure Ni was rendered and less cytocompatible. All the papers confirmed that the consequence of the formation of protective layers was in significant increase of cytocompatibility of the materials. This indicates the possible further modifications of the manufacturing process (formation of the passivation layer)
    • 

    corecore