3,412 research outputs found

    A Three-dimensional Deformable Brain Atlas for DBS Targeting. I. Methodology for Atlas Creation and Artifact Reduction.

    Get PDF
    BackgroundTargeting in deep brain stimulation (DBS) relies heavily on the ability to accurately localize particular anatomic brain structures. Direct targeting of subcortical structures has been limited by the ability to visualize relevant DBS targets.Methods and resultsIn this work, we describe the development and implementation, of a methodology utilized to create a three dimensional deformable atlas for DBS surgery. This atlas was designed to correspond to the print version of the Schaltenbrand-Bailey atlas structural contours. We employed a smoothing technique to reduce artifacts inherent in the print version.ConclusionsWe present the methodology used to create a three dimensional patient specific DBS atlas which may in the future be tested for clinical utility

    SIMS chemical analysis of extended impacts on the leading and trailing edges of LDEF experiment AO187-2

    Get PDF
    Numerous 'extended impacts' found in both leading and trailing edge capture cells were successfully analyzed for the chemical composition of projectile residues by secondary ion mass spectrometry (SIMS). Most data were obtained from the trailing edge cells where 45 of 58 impacts were classified as 'probably natural' and the remainder as 'possibly man-made debris.' This is in striking contrast to leading edge cells where 9 of 11 impacts so far measured are definitely classified as orbital debris. Although all the leading edge cells had lost their plastic entrance foils during flight, the rate of foil failure was similar to that of the trailing edge cells, 10 percent of which were recovered intact. Ultraviolet embrittlement is suspected as the major cause of failure on both leading and trailing edges. The major impediment to the accurate determination of projectile chemistry is the fractionation of volatile and refractory elements in the hypervelocity impact and redeposition processes. This effect had been noted in a simulation experiment but is more pronounced in the LDEF capture cells, probably due to the higher average velocities of the space impacts. Surface contamination of the pure Ge surfaces with a substance rich in Si, but also containing Mg and Al, provides an additional problem for the accurate determination of impactor chemistry. The effect is variable, being much larger on surfaces that were exposed to space than in those cells that remained intact. Future work will concentrate on the analyses of more leading edge impacts and the development of new SIMS techniques for the measurement of elemental abundances in extended impacts

    Dysflective cones: Visual function and cone reflectivity in long-term follow-up of acute bilateral foveolitis.

    Get PDF
    PURPOSE:Confocal adaptive optics scanning laser ophthalmoscope (AOSLO) images provide a sensitive measure of cone structure. However, the relationship between structural findings of diminished cone reflectivity and visual function is unclear. We used fundus-referenced testing to evaluate visual function in regions of apparent cone loss identified using confocal AOSLO images. METHODS:A patient diagnosed with acute bilateral foveolitis had spectral-domain optical coherence tomography (SD-OCT) (Spectralis HRA + OCT system [Heidelberg Engineering, Vista, CA, USA]) images indicating focal loss of the inner segment-outer segment junction band with an intact, but hyper-reflective, external limiting membrane. Five years after symptom onset, visual acuity had improved from 20/80 to 20/25, but the retinal appearance remained unchanged compared to 3 months after symptoms began. We performed structural assessments using SD-OCT, directional OCT (non-standard use of a prototype on loan from Carl Zeiss Meditec) and AOSLO (custom-built system). We also administered fundus-referenced functional tests in the region of apparent cone loss, including analysis of preferred retinal locus (PRL), AOSLO acuity, and microperimetry with tracking SLO (TSLO) (prototype system). To determine AOSLO-corrected visual acuity, the scanning laser was modulated with a tumbling E consistent with 20/30 visual acuity. Visual sensitivity was assessed in and around the lesion using TSLO microperimetry. Complete eye examination, including standard measures of best-corrected visual acuity, visual field tests, color fundus photos, and fundus auto-fluorescence were also performed. RESULTS:Despite a lack of visible cone profiles in the foveal lesion, fundus-referenced vision testing demonstrated visual function within the lesion consistent with cone function. The PRL was within the lesion of apparent cone loss at the fovea. AOSLO visual acuity tests were abnormal, but measurable: for trials in which the stimulus remained completely within the lesion, the subject got 48% correct, compared to 78% correct when the stimulus was outside the lesion. TSLO microperimetry revealed reduced, but detectible, sensitivity thresholds within the lesion. CONCLUSIONS AND IMPORTANCE:Fundus-referenced visual testing proved useful to identify functional cones despite apparent photoreceptor loss identified using AOSLO and SD-OCT. While AOSLO and SD-OCT appear to be sensitive for the detection of abnormal or absent photoreceptors, changes in photoreceptors that are identified with these imaging tools do not correlate completely with visual function in every patient. Fundus-referenced vision testing is a useful tool to indicate the presence of cones that may be amenable to recovery or response to experimental therapies despite not being visible on confocal AOSLO or SD-OCT images

    Detection of Excercise-Induced Ischemia by Measurement of NT-proBNP

    Get PDF
    Electrocardiographic exercise testing is the most widely used non-invasive screening test for coronary artery disease (CAD); however, both positive and negative predictive values for this procedure are hampered by relatively low sensitivity and specificity, leading to significant numbers of false negative and false positive studies. We hypothesized that NT-proBNP, a Neuro hormone secreted by cardiac myocytes in the ventricular wall in response to increased wall stress, would rise as a result of exercise-induced ischemia. If this were true, the enhancement of exercise testing by analysis of this plasma biomarker may offer significant improvement in the diagnostic accuracy of this procedure

    Transport through an impurity tunnel coupled to a Si/SiGe quantum dot

    Get PDF
    Achieving controllable coupling of dopants in silicon is crucial for operating donor-based qubit devices, but it is difficult because of the small size of donor-bound electron wavefunctions. Here we report the characterization of a quantum dot coupled to a localized electronic state, and we present evidence of controllable coupling between the quantum dot and the localized state. A set of measurements of transport through this device enable the determination of the most likely location of the localized state, consistent with an electronically active impurity in the quantum well near the edge of the quantum dot. The experiments we report are consistent with a gate-voltage controllable tunnel coupling, which is an important building block for hybrid donor and gate-defined quantum dot devices.Comment: 5 pages, 3 figure

    Fast Simulation of Open Queueing Systems

    Get PDF
    We describe a technique developed by the authors for fast simulation of open queueing networks. The technique takes advantage of the recursive nature of departure times of customers in various parts of the system. The event calendar is circumvented using these recursive relationships whenever possible. A framework for identifying these recursive aspects of a network is presented. The technique involves identifying the servers in the system at which flows merge or diverge. Knowledge about the merge and diverge points defines the dependency relationships a specific customer has with other customers at each point in the system. The concept of a system level is based on these dependency relationships.Yeshttps://us.sagepub.com/en-us/nam/manuscript-submission-guideline

    Stereotactic ablative body radiotherapy for the treatment of spinal oligometastases

    Get PDF
    Abstract not availableJ.H. Chang, S. Gandhidasan, R. Finnigan, D. Whalley, R. Nair, A. Herschtal, T. Eade, A. Kneebone, J. Ruben, M. Foote, S. Siv
    corecore