904 research outputs found

    Quantification of both the area-at-risk and acute myocardial infarct size in ST-segment elevation myocardial infarction using T1-mapping

    Get PDF
    BACKGROUND: A comprehensive cardiovascular magnetic resonance (CMR) in reperfused ST-segment myocardial infarction (STEMI) patients can be challenging to perform and can be time-consuming. We aimed to investigate whether native T1-mapping can accurately delineate the edema-based area-at-risk (AAR) and post-contrast T1-mapping and synthetic late gadolinium (LGE) images can quantify MI size at 1.5 T. Conventional LGE imaging and T2-mapping could then be omitted, thereby shortening the scan duration. METHODS: Twenty-eight STEMI patients underwent a CMR scan at 1.5 T, 3 ± 1 days following primary percutaneous coronary intervention. The AAR was quantified using both native T1 and T2-mapping. MI size was quantified using conventional LGE, post-contrast T1-mapping and synthetic magnitude-reconstructed inversion recovery (MagIR) LGE and synthetic phase-sensitive inversion recovery (PSIR) LGE, derived from the post-contrast T1 maps. RESULTS: Native T1-mapping performed as well as T2-mapping in delineating the AAR (41.6 ± 11.9% of the left ventricle [% LV] versus 41.7 ± 12.2% LV, P = 0.72; R(2) 0.97; ICC 0.986 (0.969-0.993); bias -0.1 ± 4.2% LV). There were excellent correlation and inter-method agreement with no bias, between MI size by conventional LGE, synthetic MagIR LGE (bias 0.2 ± 2.2%LV, P = 0.35), synthetic PSIR LGE (bias 0.4 ± 2.2% LV, P = 0.060) and post-contrast T1-mapping (bias 0.3 ± 1.8% LV, P = 0.10). The mean scan duration was 58 ± 4 min. Not performing T2 mapping (6 ± 1 min) and conventional LGE (10 ± 1 min) would shorten the CMR study by 15-20 min. CONCLUSIONS: T1-mapping can accurately quantify both the edema-based AAR (using native T1 maps) and acute MI size (using post-contrast T1 maps) in STEMI patients without major cardiovascular risk factors. This approach would shorten the duration of a comprehensive CMR study without significantly compromising on data acquisition and would obviate the need to perform T2 maps and LGE imaging

    Full left ventricular coverage is essential for the accurate quantification of the area- at- risk by T1 and T2 mapping

    Get PDF
    T2-weighted cardiovascular magnetic resonance (CMR) using a 3-slice approach has been shown to accurately quantify the edema-based area-at-risk (AAR) in ST-segment elevation myocardial infarction (STEMI). We aimed to compare the performance of a 3-slice approach to full left ventricular (LV) coverage for the AAR by T1 and T2 mapping and MI size. Forty-eight STEMI patients were prospectively recruited and underwent a CMR at 4 ± 2 days. There was no difference between the AARfull LV and AAR3-slices by T1 (P = 0.054) and T2-mapping (P = 0.092), with good correlations but small biases and wide limits of agreements (T1-mapping: N = 30, R2 = 0.85, bias = 1.7 ± 9.4% LV; T2-mapping: N = 48, R2 = 0.75, bias = 1.7 ± 12.9% LV). There was also no significant difference between MI size3-slices and MI sizefull LV (P = 0.93) with an excellent correlation between the two (R2 0.92) but a small bias of 0.5% and a wide limit of agreement of ±7.7%. Although MSI was similar between the 2 approaches, MSI3-slices performed poorly when MSI was <0.50. Furthermore, using AAR3-slices and MI sizefull LV resulted in ‘negative’ MSI in 7/48 patients. Full LV coverage T1 and T2 mapping are more accurate than a 3-slice approach for delineating the AAR, especially in those with MSI < 0.50 and we would advocate full LV coverage in future studies

    Impact of microvascular obstruction on semiautomated techniques for quantifying acute and chronic myocardial infarction by cardiovascular magnetic resonance

    Get PDF
    AIMS: The four most promising semiautomated techniques (5-SD, 6-SD, Otsu and the full width half maximum (FWHM)) were compared in paired acute and follow-up cardiovascular magnetic resonance (CMR), taking into account the impact of microvascular obstruction (MVO) and using automated extracellular volume fraction (ECV) maps for reference. Furthermore, their performances on the acute scan were compared against manual myocardial infarct (MI) size to predict adverse left ventricular (LV) remodelling (≥20% increase in end-diastolic volume). METHODS: 40 patients with reperfused ST segment elevation myocardial infarction (STEMI) with a paired acute (4±2 days) and follow-up CMR scan (5±2 months) were recruited prospectively. All CMR analysis was performed on CVI42. RESULTS: Using manual MI size as the reference standard, 6-SD accurately quantified acute (24.9±14.0%LV, p=0.81, no bias) and chronic MI size (17.2±9.7%LV, p=0.88, no bias). The performance of FWHM for acute MI size was affected by the acquisition sequence used. Furthermore, FWHM underestimated chronic MI size in those with previous MVO due to the significantly higher ECV in the MI core on the follow-up scans previously occupied by MVO (82 (75-88)% vs 62 (51-68)%, p<0.001). 5-SD and Otsu were precise but overestimated acute and chronic MI size. All techniques were performed with high diagnostic accuracy and equally well to predict adverse LV remodelling. CONCLUSIONS: 6-SD was the most accurate for acute and chronic MI size and should be the preferred semiautomatic technique in randomised controlled trials. However, 5-SD, FWHM and Otsu could also be used when precise MI size quantification may be adequate (eg, observational studies)

    T1 mapping and T2 mapping at 3T for quantifying the area-at-risk in reperfused STEMI patients

    Get PDF
    BACKGROUND: Whether T1-mapping cardiovascular magnetic resonance (CMR) can accurately quantify the area-at-risk (AAR) as delineated by T2 mapping and assess myocardial salvage at 3T in reperfused ST-segment elevation myocardial infarction (STEMI) patients is not known and was investigated in this study. METHODS: 18 STEMI patients underwent CMR at 3T (Siemens Bio-graph mMR) at a median of 5 (4–6) days post primary percutaneous coronary intervention using native T1 (MOLLI) and T2 mapping (WIP #699; Siemens Healthcare, UK). Matching short-axis T1 and T2 maps covering the entire left ventricle (LV) were assessed by two independent observers using manual, Otsu and 2 standard deviation thresholds. Inter- and intra-observer variability, correlation and agreement between the T1 and T2 mapping techniques on a per-slice and per patient basis were assessed. RESULTS: A total of 125 matching T1 and T2 mapping short-axis slices were available for analysis from 18 patients. The acquisition times were identical for the T1 maps and T2 maps. 18 slices were excluded due to suboptimal image quality. Both mapping sequences were equally prone to susceptibility artifacts in the lateral wall and were equally likely to be affected by microvascular obstruction requiring manual correction. The Otsu thresholding technique performed best in terms of inter- and intra-observer variability for both T1 and T2 mapping CMR. The mean myocardial infarct size was 18.8 ± 9.4 % of the LV. There was no difference in either the mean AAR (32.3 ± 11.5 % of the LV versus 31.6 ± 11.2 % of the LV, P = 0.25) or myocardial salvage index (0.40 ± 0.26 versus 0.39 ± 0.27, P = 0.20) between the T1 and T2 mapping techniques. On a per-slice analysis, there was an excellent correlation between T1 mapping and T2 mapping in the quantification of the AAR with an R2 of 0.95 (P < 0.001), with no bias (mean ± 2SD: bias 0.0 ± 9.6 %). On a per-patient analysis, the correlation and agreement remained excellent with no bias (R2 0.95, P < 0.0001, bias 0.7 ± 5.1 %). CONCLUSIONS: T1 mapping CMR at 3T performed as well as T2 mapping in quantifying the AAR and assessing myocardial salvage in reperfused STEMI patients, thereby providing an alternative CMR measure of the the AAR

    Prospective comparison of novel dark blood late gadolinium enhancement with conventional bright blood imaging for the detection of scar

    Get PDF
    BACKGROUND: Conventional bright blood late gadolinium enhancement (bright blood LGE) imaging is a routine cardiovascular magnetic resonance (CMR) technique offering excellent contrast between areas of LGE and normal myocardium. However, contrast between LGE and blood is frequently poor. Dark blood LGE (DB LGE) employs an inversion recovery T2 preparation to suppress the blood pool, thereby increasing the contrast between the endocardium and blood. The objective of this study is to compare the diagnostic utility of a novel DB phase sensitive inversion recovery (PSIR) LGE CMR sequence to standard bright blood PSIR LGE. METHODS: One hundred seventy-two patients referred for clinical CMR were scanned. A full left ventricle short axis stack was performed using both techniques, varying which was performed first in a 1:1 ratio. Two experienced observers analyzed all bright blood LGE and DB LGE stacks, which were randomized and anonymized. A scoring system was devised to quantify the presence and extent of gadolinium enhancement and the confidence with which the diagnosis could be made. RESULTS: A total of 2752 LV segments were analyzed. There was very good inter-observer correlation for quantifying LGE. DB LGE analysis found 41.5% more segments that exhibited hyperenhancement in comparison to bright blood LGE (248/2752 segments (9.0%) positive for LGE with bright blood; 351/2752 segments (12.8%) positive for LGE with DB; p < 0.05). DB LGE also allowed observers to be more confident when diagnosing LGE (bright blood LGE high confidence in 154/248 regions (62.1%); DB LGE in 275/324 (84.9%) regions (p < 0.05)). Eighteen patients with no bright blood LGE were found to have had DB LGE, 15 of whom had no known history of myocardial infarction. CONCLUSIONS: DB LGE significantly increases LGE detection compared to standard bright blood LGE. It also increases observer confidence, particularly for subendocardial LGE, which may have important clinical implications

    Gene sequence variations of the platelet P2Y12 receptor are associated with coronary artery disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The platelet P2Y<sub>12 </sub>receptor plays a key role in platelet activation. The H2 haplotype of the P2Y<sub>12 </sub>receptor gene (<it>P2RY12</it>) has been found to be associated with maximal aggregation response to adenosine diphosphate (ADP) and with increased risk for peripheral arterial disease. No data are available on its association with coronary artery disease (CAD).</p> <p>Methods </p> <p>The H2 haplotype of the <it>P2RY12 </it>was determined in 1378 unrelated patients of both sexes selected according to the presence of significant coronary artery disease (CAD group) or having normal coronary angiogram at cardiac catheterization (CAD-free group). Significant coronary artery disease was angiographically determined, and was defined as a greater than 50% visually estimated luminal diameter stenosis in at least one major epicardial coronary artery.</p> <p>Results</p> <p>In the studied population 71.9% had CAD (n = 991) and 28.1% had normal coronary angiogram (n = 387). H2 haplotype carriers were more frequent in the CAD group (p = 0.03, OR = 1.36, 95%CI = 1.02–1.82). The H2 haplotype was significantly associated with CAD in non-smokers (p = 0.007, OR = 1.83 95%CI = 1.17–2.87), but not in smokers. The association remained significant after adjustment for other covariates (age, triglycerides, HDL, hypertension, diabetes) by multivariate logistic regression (p = 0.004, OR = 2.32 95%CI = 1.30–4.15).</p> <p>Conclusion</p> <p>Gene sequence variations of the P2Y<sub>12 </sub>receptor gene are associated with the presence of significant CAD, particularly in non-smoking individuals.</p

    The VANDELS Survey: New constraints on the high-mass X-ray binary populations in normal star-forming galaxies at 3 < z < 5.5

    Get PDF
    We use VANDELS spectroscopic data overlapping with the ≃7 Ms Chandra Deep Field South survey to extend studies of high-mass X-ray binary systems (HMXBs) in 301 normal star-forming galaxies in the redshift range 3 6 may be ≳0.25 dex higher than previously estimated

    The VANDELS survey: Global properties of CIII]lambda 1908 angstrom emitting star-forming galaxies at z similar to 3

    Get PDF
    Context. Strong nebular emission is ubiquitous in galaxies that contribute to cosmic reionization at redshift za a 6. High-ionization UV metal lines, such as CIII]λ1908 A, show high equivalent widths (EW) in these early galaxies, suggesting harder radiation fields at low metallicity than low-z galaxies of similar stellar mass. Understanding the physical properties driving the observed UV nebular line emission at high-z requires large and very deep spectroscopic surveys, which are now only accessible out to za a a 4. Aims. We study the mean properties of a large representative sample of 217 galaxies showing CIII] emission at 2a <a za <a 4, selected from a parent sample of a 750 main-sequence star-forming galaxies in the VANDELS survey. These CIII] emitters have a broad range of UV luminosities, allowing for a detailed stacking analysis to characterize their stellar mass, star formation rate (SFR), and metallicity as a function of the UV emission line ratios, EWs, and the carbon-to-oxygen (C/O) abundance ratio. Methods. Stacking provides unprecedented high signal-to-noise (S/N) spectra for CIII] emitters over more than three decades in luminosity, stellar mass, and SFR. This enables a full spectral fitting to derive stellar metallicities for each stack. Moreover, we use diagnostics based on photoionization models and UV line ratios to constrain the ionization sources of the galaxies and derive the C/O abundance. Results. Reliable CIII] detections (S/Na a ¥a 3) represent a 30% of the parent sample. However, stacked spectra of non-detections (S/Na <a 3) show weak (EW a 2 A) CIII] emission, suggesting that this line is common in normal star-forming galaxies at za a a 3. On the other hand, extreme CIII] emitters (EW(CIII]) a 8 A) are exceedingly rare (a 3%) in VANDELS. The UV line ratios of the sample suggest no ionization source other than massive stars. Stacks with larger EW(CIII]) show larger EW(Lyα) and lower metallicity, but not all CIII] emitters are Lyα emitters. The stellar metallicities of CIII] emitters are not significantly different from that of the parent sample, increasing from a 10% to a 40% solar for stellar masses log(Ma/Ma) a 9a? 10.5. The stellar mass-metallicity relation of the CIII] emitters is consistent with previous works, exhibiting a strong evolution from za =a 0 to za a a 3. The C/O abundances of the sample range between 35%a? 150% solar, with a noticeable increase with FUV luminosity and a smooth decrease with the CIII] EW. Here, we discuss the CIII] emitters in the C/Oa Fe/H and the C/Oa O/H planes and we find that they follow stellar and nebular abundance trends consistent with those of Milky Way halo and thick-disk stars and local HII galaxies, respectively. A qualitative agreement is also found with chemical evolution models, which suggests that CIII] emitters at za a a 3 are experiencing an active phase of chemical enrichment. Conclusions. Our results provide new insights into the nature of UV line emitters at za a a 2a 4, paving the way for future studies at higher z using the James Webb Space Telescope

    The origin of large molecules in primordial autocatalytic reaction networks

    Get PDF
    Large molecules such as proteins and nucleic acids are crucial for life, yet their primordial origin remains a major puzzle. The production of large molecules, as we know it today, requires good catalysts, and the only good catalysts we know that can accomplish this task consist of large molecules. Thus the origin of large molecules is a chicken and egg problem in chemistry. Here we present a mechanism, based on autocatalytic sets (ACSs), that is a possible solution to this problem. We discuss a mathematical model describing the population dynamics of molecules in a stylized but prebiotically plausible chemistry. Large molecules can be produced in this chemistry by the coalescing of smaller ones, with the smallest molecules, the `food set', being buffered. Some of the reactions can be catalyzed by molecules within the chemistry with varying catalytic strengths. Normally the concentrations of large molecules in such a scenario are very small, diminishing exponentially with their size. ACSs, if present in the catalytic network, can focus the resources of the system into a sparse set of molecules. ACSs can produce a bistability in the population dynamics and, in particular, steady states wherein the ACS molecules dominate the population. However to reach these steady states from initial conditions that contain only the food set typically requires very large catalytic strengths, growing exponentially with the size of the catalyst molecule. We present a solution to this problem by studying `nested ACSs', a structure in which a small ACS is connected to a larger one and reinforces it. We show that when the network contains a cascade of nested ACSs with the catalytic strengths of molecules increasing gradually with their size (e.g., as a power law), a sparse subset of molecules including some very large molecules can come to dominate the system.Comment: 49 pages, 17 figures including supporting informatio
    corecore