425 research outputs found

    The preparation of the Shutdown Dose Rate experiment for the next JET Deuterium-Tritium campaign

    Get PDF
    The assessment of the Shutdown Dose Rate (SDR) due to neutron activation is a major safety issue for fusion devices and in the last decade several benchmark experiments have been conducted at JET during Deuterium-Deuterium experiments for the validation of the numerical tools used in ITER nuclear analyses. The future Deuterium-Tritium campaign at JET (DTE2) will provide a unique opportunity to validate the codes under ITER-relevant conditions through the comparison between numerical predictions and measured quantities (C/E). For this purpose, a novel SDR experiment, described in the present work, is in preparation in the frame of the WPJET3-NEXP subproject within EUROfusion Consortium. The experimental setup has been accurately designed to reduce measurement uncertainties; spherical air-vented ionization chambers (ICs) will be used for on-line ex-vessel decay gamma dose measurements during JET shutdown following DT operations and activation foils have been selected for measuring the neutron fluence near ICs during operations. Active dosimeters (based on ICs) have been calibrated over a broad energy range (from about 30 keV to 1.3 MeV) with X and gamma reference beam qualities. Neutron irradiation tests confirmed the capability of active dosimeters of performing on-line decay gamma dose rate measurements, to follow gamma dose decay at the end of neutron irradiation as well as insignificant activation of the ICs

    Gene silencing of endothelial von Willebrand factor reduces the susceptibility of human endothelial cells to SARS-CoV-2 infection

    Get PDF
    Mechanisms underlying vascular endothelial susceptibility to infection by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are not fully understood. Emerging evidence indicates that patients lacking von Willebrand factor (vWF), an endothelial hallmark, are less severely affected by SARS-CoV-2 infection, yet the precise role of endothelial vWF in modulating coronavirus entry into endothelial cells is unknown. In the present study, we demonstrated that effective gene silencing by short interfering RNA (siRNA) for vWF expression in resting human umbilical vein endothelial cells (HUVECs) significantly reduced by 56% the cellular levels of SARS-CoV-2 genomic RNA. Similar reduction of intracellular SARS-CoV-2 genomic RNA levels was observed in non-activated HUVECs treated with siRNA targeting angiotensin-converting enzyme 2 (ACE2), the cellular gateway to coronavirus. By integrating quantitative information from real-time PCR and high-resolution confocal imaging, we demonstrated that ACE2 gene expression and its plasma membrane localization in HUVECs were both markedly reduced after treatment with siRNA anti-vWF or anti-ACE2. Conversely, siRNA anti-ACE2 did not reduce endothelial vWF gene expression and protein levels. Finally, SARS-CoV-2 infection of viable HUVECs was enhanced by overexpression of vWF, which increased ACE2 levels. Of note, we found a similar increase in interferon-ÎČ mRNA levels following transfection with untargeted, anti-vWF or anti-ACE2 siRNA and pcDNA3.1-WT-VWF. We envision that siRNA targeting endothelial vWF will protect against productive endothelial infection by SARS-CoV-2 through downregulation of ACE2 expression and might serve as a novel tool to induce disease resistance by modulating the regulatory role of vWF on ACE2 expression

    Nuclear Analyses for the Assessment of the Loads on the ITER Radial Neutron Camera In-Port System and Evaluation of Its Measurement Performances

    Get PDF
    The radial neutron camera (RNC) is a key ITER diagnostic system designed to measure the uncollided 14- and 2.5-MeV neutrons from deuterium-tritium (DT) and deuterium-deuterium (DD) fusion reactions, through an array of detectors covering a full poloidal plasma section along collimated lines of sight (LoS). Its main objective is the assessment of the neutron emissivity/alpha source profile and the total neutron source strength, providing spatially resolved measurements of several parameters needed for fusion power estimation, plasma control, and plasma physics studies. The present RNC layout is composed of two fan-shaped collimating structures viewing the plasma radially through vertical slots in the diagnostic shielding module (DSM) of ITER Equatorial Port 1 (EP01): the ex-port subsystem and the in-port one. The ex-port subsystem, devoted to the plasma core coverage, extends from the Port Interspace to the Bioshield Plug: it consists of a massive shielding unit hosting two sets of collimators lying on different toroidal planes, leading to a total of 16 interleaved LoS. The in-port system consists of a cassette, integrated inside the port plug DSM, containing two detectors per each of the six LoS looking at the plasma edges. The in-port system must guarantee the required measurement performances in critical operating conditions in terms of high radiation levels, given its proximity to the plasma neutron source. This article presents an updated neutronic analysis based on the latest design of the in-port system and port plug. It has been performed by means of the Monte Carlo MCNP code and provides nuclear loads on the in-port RNC during normal operating conditions (NOC) and inputs for the measurement performance analysis

    Wegener's granulomatosis: an update on diagnosis and therapy

    Get PDF
    Wegener's granulomatosis (WG) is a unique clinicopathological disease characterized by necrotizing granulomatous vasculitis of the respiratory tract, pauci-immune necrotizing glomerulonephritis and small-vessel vasculitis. Owing to its wide range of clinical manifestations, WG has a broad spectrum of severity that includes the potential for alveolar hemorrhage or rapidly progressive glomerulonephritis, which are immediately life threatening. WG is associated with the presence of circulating antineutrophil cytoplasm antibodies (c-ANCAs). The most widely accepted pathogenetic model suggests that c-ANCA-activated cytokine-primed neutrophils induce microvascular damage and a rapid escalation of inflammation with recruitment of mononuclear cells. The diagnosis of WG is made on the basis of typical clinical and radiologic findings, by biopsy of involved organ, the presence of c-ANCA and exclusion of all other small-vessel vasculitis. Currently, a regimen consisting of daily cyclophosphamide and corticosteroids is considered standard therapy. A number of trials have evaluated the efficacy of less-toxic immunosuppressants and antibacterials for treating patients with WG, resulting in the identification of effective alternative regimens to induce or maintain remission in certain subpopulations of patients. Recent investigation has focused on other immunomodulatory agents (e.g., TNF-alpha inhibitors and anti-CD20 antibodies), intravenous immunoglobulins and antithymocyte globulins for treating patients with resistant WG

    The electron capture in 163^{163}Ho experiment – ECHo

    Get PDF
    Neutrinos, and in particular their tiny but non-vanishing masses, can be considered one of the doors towards physics beyond the Standard Model. Precision measurements of the kinematics of weak interactions, in particular of the 3^{3}H ÎČ-decay and the 163^{163}Ho electron capture (EC), represent the only model independent approach to determine the absolute scale of neutrino masses. The electron capture in 163^{163}Ho experiment, ECHo, is designed to reach sub-eV sensitivity on the electron neutrino mass by means of the analysis of the calorimetrically measured electron capture spectrum of the nuclide 163^{163}Ho. The maximum energy available for this decay, about 2.8 keV, constrains the type of detectors that can be used. Arrays of low temperature metallic magnetic calorimeters (MMCs) are being developed to measure the 163^{163}Ho EC spectrum with energy resolution below 3 eV FWHM and with a time resolution below 1 Όs. To achieve the sub-eV sensitivity on the electron neutrino mass, together with the detector optimization, the availability of large ultra-pure 163^{163}Ho samples, the identification and suppression of background sources as well as the precise parametrization of the 163^{163}Ho EC spectrum are of utmost importance. The high-energy resolution 163^{163}Ho spectra measured with the first MMC prototypes with ion-implanted 163^{163}Ho set the basis for the ECHo experiment. We describe the conceptual design of ECHo and motivate the strategies we have adopted to carry on the present medium scale experiment, ECHo-1K. In this experiment, the use of 1 kBq 163^{163}Ho will allow to reach a neutrino mass sensitivity below 10 eV/c2^{2}. We then discuss how the results being achieved in ECHo-1k will guide the design of the next stage of the ECHo experiment, ECHo-1M, where a source of the order of 1 MBq 163^{163}Ho embedded in large MMCs arrays will allow to reach sub-eV sensitivity on the electron neutrino mass

    Large-scale mass wasting in the western Indian Ocean constrains onset of East African rifting

    Get PDF
    Faulting and earthquakes occur extensively along the flanks of the East African Rift System, including an offshore branch in the western Indian Ocean, resulting in remobilization of sediment in the form of landslides. To date, constraints on the occurrence of submarine landslides at margin scale are lacking, leaving unanswered a link between rifting and slope instability. Here, we show the first overview of landslide deposits in the post-Eocene stratigraphy of the Tanzania margin and we present the discovery of one of the biggest landslides on Earth: the Mafia mega-slide. The emplacement of multiple landslides, including the Mafia mega-slide, during the early-mid Miocene is coeval with cratonic rifting in Tanzania, indicating that plateau uplift and rifting in East Africa triggered large and potentially tsunamigenic landslides likely through earthquake activity and enhanced sediment supply. This study is a first step to evaluate the risk associated with submarine landslides in the region

    ITER oriented neutronics benchmark experiments on neutron streaming and shutdown dose rate at JET

    Get PDF
    Neutronics benchmark experiments are conducted at JET in the frame of WPJET3 NEXP within EUROfusion Consortium for validating the neutronics codes and tools used in ITER nuclear analyses to predict quantities such as the neutron flux along streaming paths and dose rates at the shutdown due to activated components. The preparation of neutron streaming and shutdown dose rate experiments for the future Deuterium-Tritium operations (DTE2 campaign) are in progress. This paper summarizes the status of measurements and analyses in progress in the current Deuterium–Deuterium (DD) campaign and the efforts in preparation for DTE2

    DTT - Divertor Tokamak Test facility: A testbed for DEMO

    Get PDF
    The effective treatment of the heat and power exhaust is a critical issue in the road map to the realization of the fusion energy. In order to provide possible, reliable, well assessed and on-time answers to DEMO, the Divertor Tokamak Test facility (DTT) has been conceived and projected to be carried out and operated within the European strategy in fusion technology. This paper, based on the invited plenary talk at the 31st virtual SOFT Conference 2020, provides an overview of the DTT scientific proposal, which is deeply illustrated in the 2019 DTT Interim Design Report
    • 

    corecore